WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc.
Please read all instructions carefully before beginning installation. Save them for future reference. Before removing any wiring from your existing thermostat, its wires must be labeled with their terminal designations. Ignore the color of the wires since they may not comply with any standard.
Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference.
The PSP511A/PSP511LA can be used with most single stage 24 volt gas, oil or electric heating and air conditioning systems, single stage heat pumps, or gas millivolt heating systems. It cannot be used with 3 wire zone valves, 120 volt heating systems, or multi stage heat pumps. Ask your dealer for other LUX thermostats to control those systems.
CAUTION The PSP511A/PSP511LA is protected against normal static electric discharges. To minimize the risk of damaging the unit in extremely dry weather, touch a grounded metal object before touching your thermostat.
Please read all instructions carefully before beginning installation.
CAUTION Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. Do not turn electricity back on until work is completed.
TOOLS REQUIRED
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below.
CAUTION
The PSP511A/PSP511LA alternately displays the current time and the room temperature, and the day of the week. The current program period, MORN, DAY, EVE or NITE is indicated by an arrow at the left edge of the screen. Set temperatures are indicated in the right side of the display.
With batteries installed, you can make program or setting changes with the thermostat body on the wall, or conveniently removed from its base plate.
TEMPERATURE CONTROL MODES:
The Mode switch has three positions HEAT, OFF, and COOL. In the winter, set the system switch to HEAT to control your heating system. In the summer, set the switch to COOL to control your air conditioner. In spring and fall or when the windows are open, you can set the switch OFF.
UP/DOWN/CHANGE KEYS:
UP/DOWN keys are just right of the unit’s display. They are used to adjust set temperatures and change other settings.
CHANGING TEMPERATURE AND OTHER SETTINGS:
If there are many choices for a value, usually that setting will automatically advance by holding the Up or Down key. Some settings though, must be changed one press at a time.
DISPLAY ILLUMINATION:
Press any key to illuminate (PSP511LA only) the display. Pressing any key will keep the display illuminated until no button has been pressed for approximately 20 seconds.
FAN MODES:
The fan switch has two positions; AUTO will automatically run your system’s fan as required for heating and cooling only. ON runs your system’s fan continuously.
NOTE
The FAN switch works only if your system provides a wire for the PSP511A/PSP511LA’s “G” terminal.
SETTING THE TIME AND DAY:
Open the door on the front of the thermostat. Rotate the dial to the SET DAY/TIME position. You should see the display pictured below with a day of the week flashing.
When you are finished setting the day and time, rotate the dial to RUN to return to normal operation or to another position to continue programming.
HARDWARE RESET
This button will read option jumper positions, before the unit begins normal operation. It is located inside on the rear of the unit’s circuit board. It is a small square component with a white button at it’s center. Pressing Hardware Reset will allow the unit to read the new jumper settings without losing your program.
SOFTWARE RESET
Use this front panel RESET to return all software settings and programs to their default values. Option jumpers will be read and operation will correspond to their current positions. To assist in reprogramming, copy your programs into the chart provided before using SOFTWARE RESET.
PROGRAMMING CHART
DAY | PERIOD | HEAT | COOL | ||
TIME | TEMP. | TIME | TEMP. | ||
MON. THRU FRI. | MORN | ||||
DAY | |||||
EVE | |||||
NIGHT | |||||
SAT. and SUN. | MORN | ||||
DAY | |||||
EVE | |||||
NIGHT |
The PSP511A/PSP511LA provides two separate programs, one for heating the other for cooling. Each program has separate settings for weekdays and week-ends. Every day a program cycles through four independent periods. You can use the default programs or alter them to suit your schedule.
DEFAULT ENERGY STAR® TEMPERATURE PROGRAM
As supplied from the factory, the following ENERGY STAR® approved program will be used for temperature control in RUN mode. This program and all other software settings may be restored to their default values via a SOFTWARE RESET.
PERIOD | HEAT MODE | COOL MODE |
Morning | 6:00 AM 70°F (21°C) | 6:00 AM 78°F (26°C) |
Day | 8:00 AM 62°F (17°C) | 8:00 AM 85°F (29°C) |
Evening | 6:00 PM 70°F (21°C) | 6:00 PM 78°F (26°C) |
Night | 10:00 PM 62°F (17°C) | 10:00 PM 82°F (28°C) |
EDITING HEAT OR COOL PROGRAMS
You can review or change any preset times and/or temperatures to suit your schedule for each day of the week. The four periods each day are Morning(MORN), Day,(DAY) Evening(EVE), and Night(NITE).
WEEKDAY PROGRAMMING
WEEKEND PROGRAMMING
TEMPERATURE OVERRIDE
OVERRIDE allows you to change the current SET TEMPERATURE in HEAT or COOL until the next program period without changing your temperature control programs.
TEMPERATURE HOLD
HOLD may be used for manual temperature control. HOLD is the simplest means to set and maintain a fixed temperature. It allows you to set and maintain a temperature Set Point indefinitely in Heat or Cool without concern for programming. To initiate a HOLD:
TEMPERATURE SWING
A thermostat works by turning your heating or cooling system on or off whenever the room temperature varies from the set-point temperature. This variation is the “swing.” Your system should cycle on about 3 to 6 times per hour. A smaller swing number increases the number of cycles, so room temperature is more constant. A larger swing number decreases the number of cycles, but saves energy in most cases.
SWING SETTING
JUMPER SETTINGS
There are three jumpers and one switch. Each controls a setting corresponding to its position.
5MIN/2MIN MINIMUM RUN TIME – JP3
The position of J3 sets the minimum length of time that the thermostat must remain with Heat or Cool either on or off before it will automatically switch to the alternate On or Off state. This feature prevents short cycling and provides compressor protection for cooling units. Choices are 2 or 5 minutes.
TEMPERATURE DISPLAY FORMAT °F/C – JP2
The position of this jumper controls whether the temperature is displayed in degrees F° or C°
TIME DISPLAY FORMAT 12/24 HR CLOCK – JP1
The position of this jumper controls whether time is displayed in 12 hour or 24 hour Military Time format.
REPOSITIONING JUMPERS
To change a setting, the jumper must be repositioned and a HARDWARE RESET must be performed. Note that as long as you press the Hardware Reset button (inside) and not the Software Reset button (front), you will change settings and not lose your program.These jumpers are located inside the thermostat on the rear of its circuit board. To access them, remove the unit from the wall by pressing up on the thumb latch at the bottom of the thermostat and swinging the body out and away.
GAS/ELECTRIC SWITCH
This switch controls whether the thermostat requests the system fan to run when it is in HEAT mode with the fan set to AUTO. Then with the switch set to GAS the fan is controlled by the heating system itself and the terminal will remain inactive. With the gas switch set to Electric (ELEC), the fan is controlled by the thermostat.
The table pictured below is also printed on the circuit board. The closed or shorted position is that which covers both a jumpers pins. To prevent its loss in the open position, a jumper may be placed over one pin only. After jumpers have been changed, press the HARDWARE RESET button for the changes to take effect. See HARDWARE RESET
WARNING
Use Energizer® or DURACELL® Alkaline Batteries Only.
INSTALLING BATTERIES/ MAINTENANCE
When battery-powered, your PSP511A/PSP511LA requires battery replacement at least once a year or when the battery “LO BATT” indicator is visible in the display.
If you have any problems installing or using this thermostat, please reread the instructions carefully or visit our online technical support at www.luxproproducts.com. Technical assistance is available through our Technical Service Number. If you require assistance, please call our office between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday through Friday. The number is (856) 234-8803.
Limited Warranty: If this unit fails because of defects in materials or workmanship within one year of date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to one year from date of original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which the purchase was made along with proof of purchase. Please refer to “Technical Assistance” before returning your thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.
Download manual
LUXPRO PSP511A ELECTRONIC THERMOSTAT Installaiton Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…