IMPORTANT!
Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required for your particular installation. Please save for future reference.
CAUTION
Please read all instructions carefully before beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below.
REMOVING THE OLD THERMOSTAT
Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps.
MOUNTING THE PSP211 ON THE WALL
NOTE If you have an electric system and the blower does not operate after installation, find the electric/gas heat jumper on the back of the body. Move the jumper to the ELEC position.
The PSP211 requires batteries to operate your furnace and retain its programming in memory. Replace the batteries when the REPLACE indicator appears in the display or at least once a year.
PROGRAMMING CHART
DAY | PERIOD | HEAT | COOL | ||
TIME | TEMP. | TIME | TEMP. | ||
MON. THRU FRI. | MORN | ||||
DAY | |||||
EVE | |||||
NIGHT | |||||
SAT. and SUN. | MORN | ||||
DAY | |||||
EVE | |||||
NIGHT |
The PSP211 alternately displays the current time and the room temperature. It also displays the day of the week and the currently active program period that is controlling the temperature: MORN, DAY, EVE, or NITE.
The set point temperature will appear in the right side of the display. In the winter, set the system switch to HEAT to control your heating system. In the summer, set the switch to COOL to control your air conditioner. In spring and fall or when windows are open, you can set the system switch OFF. Setting the FAN switch to AUTO automatically runs your system’s fan during heating and cooling. Setting the FAN switch to ON runs your system’s fan continuously even without heating or cooling.
This thermostat is “armchair programmable” You can make any program or setting changes with the thermostat body off or on the wall thermostat base.
NOTE
The FAN switch works only if your system provides a wire for the PSP211’s “G” terminal.
THE BUILT-IN ENERGY STAR® PROGRAMS
Push in the RESET key. This sets the default heating and cooling programs. To review the default programs, move the Speed Slide to SET WEEKDAY or SET WEEKEND. You can use the default programs as shown, or change them as you wish. Each day is divided into four periods. Each period has its own starting time and temperature.
PERIOD | HEAT | COOL | |
WEEKDAYS | MORN | 6:00 AM 70° | 6:00 AM 78° |
preprograms | DAY | 8:00 AM 62° | 8:00 AM 85° |
EVE | 6:00 PM 70° | 6:00 PM 78° | |
NIGHT | 10:00 PM 62° | 10:00 PM 82° | |
MORN | 6:00 AM 70° | 6:00 AM 78° | |
WEEKEND | DAY | 8:00 AM 62° | 8:00 AM 85° |
preprograms | EVE | 6:00 PM 70° | 6:00 PM 78° |
NIGHT | 10:00 PM 62° | 10:00 PM 82° |
PROGRAMMING THE PSP211
You can change any preset times and/or temperatures to suit your schedules for the weekday and weekend programs. Each period (Morning, Day, Evening, and Night) is programmed for HEAT and for COOL.
Select HEAT to program the PSP211 for controlling your heater. OR Select COOL to program the PSP211 for controlling your air conditioner.
Slide the Speed Slide to SET WEEKDAY PROGRAM. To program the weekends SET WEEKEND. With Slide on SET WEEKDAY PROGRAM, you will see the display above.
SETTING THE TIME AND DAY
CAUTION
The PSP211 is protected against normal static electric discharges. However, in extremely dry weather you should touch another metal object before the PSP211 to avoid potential loss of programs. Move the Speed Slide to SET DAY/TIME position. You should see the display pictured above with a day of the week flashing. When you are finished setting the day and time, rotate the dial to RUN to return to normal operation or to another position to continue programming.
TEMPERATURE OVERRIDE AND TEMPERATURE HOLD
These features let you change the current Set Temperature without changing the programs stored in your thermostat’s memory.
TEMPORARY TEMPERATURE OVERRIDE
TEMPERATURE HOLD
TEMPERATURE SWING
A thermostat works by turning your heating or cooling system on and off whenever the room temperature varies a certain number of degrees from the set-point temperature. This variation is the “swing.”
Your system should cycle on about 3 to 6 times per hour. A smaller swing number increases the number of cycles, so room temperature is more constant. Setting “1” is approximately 1/4°F. Each increase of 1 value increases the swing by approximately 1/4°F.
A larger swing number decreases the number of cycles, and may save energy in some cases.
WARNING
Making these changes will require you to reset the thermostat. Copy any of your customized programs onto the blank chart. This will be your reference to re-enter the programs afterwards.
CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK
WARNING: Making these changes will require you to reset the thermostat. Copy any of your customized programs onto the chart below. This will be your reference to reenter the programs afterwards.
Your thermostat has an internal timer built in to protect your compressor. The timer forces a minimum on/off time of 5 minutes. You may change this minimum on/off time to 2 minutes. To accomplish this, remove the jumper labeled JP3. You must press the small reset button on the face of the thermostat for the changes to take effect.
TECHNICAL SERVICE
If you have any problems installing or using this thermostat, please reread the instructions carefully. Technical Service is available through our Technical Service Number. If you require assistance, please
call our offices between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday through Friday. The number is (856) 234-8803 or visit our online technical support at www.luxproducts.com.
Limited Warranty: If this unit fails because of defects in materials or workmanship within one year of date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to one year from date of original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which purchase was made, along with proof of purchase. Please refer to Technical Service Section before returning thermostat.
Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.
Download manual:
LUXPRO PSP211 SERIES ELECTRONIC THERMOSTAT Installation Manual
LUXPRO PSP211 SERIES ELECTRONIC THERMOSTAT Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…