Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference.
COMPATIBILITY
Your PSP300 Programmable Outlet Thermostat is compatible with all mechanically controlled: 120Volt, 15 Amp, 60 Hz, window air conditioning units and portable space heaters. It is also compatible with electronically controlled: 120Volt, 15 Amp, 60 Hz, window air conditioning units that have automatic restart of cooling after power resumption**. It cannot be used with electronically controlled space heaters. In addition, it cannot be used with typical 24 Volt systems, hydronic systems, or heat pumps. Ask your dealer for other LUXPRO thermostats to control those systems. ** Electronically controlled units can usually be identified by their digital readout. To learn whether a particular model offers automatic restart of cooling or heating after power resumption, refer to their manual or manufacturer.
TOOLS REQUIRED: Small regular screwdriver
ELECTRICAL RATINGS
WARNINGS :
LOCATION:
PREPARING THE UNIT
MOUNTING
COMPLETING YOUR INSTALLATION
RUN MODE
For the thermostat to function, the dial on the face of the thermostat must be turned to the RUN position. If you forget to do this, it will not work and the door will not close all the way.
UP/DOWN CHANGE KEYS
These are the two upper keys, just right of the unit’s display. They are used to adjust set temperatures and make other setting changes. Pressing these keys once will adjust a setting one step in the associated direction. If there are many choices for a value, usually that setting will advance while holding one of these keys. Some settings though, must be changed one press at a time.
SET DAY AND TIME
To set the correct time after the unit has lost power or after reset:
TEMPERATURE CONTROL MODES
When a unit has first been powered up with the dial in the RUN position, your thermostat will begin to control your heating and/or air conditioning system according to it’s default ENERGY STAR® approved program. There is a 2-position slide switch to change temperature control modes. Slide the switch to the mode you would like to use.
HEAT
Use HEAT mode to warm your home with a Space Heater. In HEAT mode, HEAT is displayed right of the set temperature.
COOL
Use COOL mode to control your Window Air Conditioner, cooling your home. In COOL mode, COOL is displayed right of the set temperature.
ON/OFF SWITCH
Slide the SLIDE switch to OFF when no heating or cooling is desired. Heating and cooling will be disabled, even though the set temperature, room temperature, and time will still be in the display.
DEFAULT PROGRAM
As supplied by the factory, your thermostat will use its default ENERGY STAR® approved program for temperature control. This program and all other settings may be restored to their default values via a SOFTWARE RESET. Please refer to the DEFAULT TEMPERATURE PROGRAM for program times and temperatures.
HOLD
The hold is the simplest method to maintain fixed set temperatures. Press HOLD once to enter the temperature HOLD while in RUN or OVERRIDE. HOLD will be displayed on the bottom of the display. Pressing this button again will toggle HOLD off and return the unit to RUN and the programmed set temperature. Changing system mode or rotating the SPEED DIAL® will also cancel a HOLD.
TEMPERATURE OVERRIDE
OVERRIDE allows you to change the current SET TEMPERATURE in HEAT of COOL until the next program period without changing your temperature control programs. Press an arrow key once. While the Set Temperature is flashing; press an UP or DOWN key to adjust the set temperature by one degree in the associated direction. Holding the key will automatically advance the setting in the associated direction. The OVERRIDE will be canceled at the start of the next program period, and the temperature setting will return to its programmed value. An OVERRIDE may be terminated by rotating the dial, switching the mode to OFF, or initiating a Hold. Adjusting the set temperature to its program value will also cancel an OVERRIDE
EDITING HEAT OR COOL PROGRAMS
The PSP300 provides two separate programs, one for heating and the other for cooling. Each program has separate settings for weekdays and weekends. Every day a program cycles through four independent periods. You can use the default programs or alter them to suit your schedule.
DEFAULT TEMPERATURE PROGRAM
As supplied by the factory, the following ENERGY STAR® approved program will be used for temperature control in RUN MODE. This program and all other software settings may be restored to their default values via a SOFTWARE RESET.
WEEKDAY PROGRAMMING
To change the HEAT or COOL program:
WEEKEND PROGRAMMING
Weekend programming is identical to weekday programming except that you must rotate the dial to SET WEEKEND PROGRAMS and the days that you will program are Sa and Su together. This two day program will repeat
CALIBRATION OFF SET
Your thermostat is accurately calibrated at the factory to within + 1°F. An offset value up to +5°F may be added to the temperature value that the thermostat measures. This may allow you to match this thermostat to another. To change this offset from its default value of 0:
SOFTWARE RESET
Use this feature to make all settings and programs return to their default values. Press and release [RESET] button using a pen or pencil. It will perform a system check and then returns all settings to their original default values before initiating normal operation.
TEMPERATURE VARIATION / SWING
Your thermostat works by turning your heating or cooling system on and off whenever the room temperature varies a certain number of degrees from the set-point temperature. This variation is the “swing”. Your system should cycle on about 3 to 6 times per hour. A smaller swing number increases the number of cycles, so room temperature is more constant. A larger swing number decreases the number of cycles, saving energy in most cases.
SWING ADJUSTMENT
This setting controls when the heating or cooling turns on and off.
The Swing setting sets the temperature variation the system allows above or below the set temperature before turning on the heating or Cooling. To change this value:
TEMPERATURE DISPLAY FORMAT
This feature allows you to display temperature in either degrees C or degrees F. To toggle the display mode from Fahrenheit to Celsius or vice versa press and release [NEXT] and [HOLD] simultaneously in <SET WEEKDAY PROGRAMS> position
The PSP300 comes with (2) G13A size 1.5V Alkaline Button Cell Batteries. During normal use, these batteries are used for the clock only. However, they also serve as backup power to retain your programs and settings if you unplug it from the wall. These (2) batteries will need to be changed once every year. The thermostat will alert you when the batteries are low by displaying “LO BATT” in the display.
BATTERY INSTALLATION
TECHNICAL ASSISTANCE
you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance Department at 856- 234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproproducts.com. Our web site offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience
Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of date of original purchase, LUX Products Corporation will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from date of original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating wholesaler from which purchase was made, along with proof of purchase. Please refer to “TECHNICAL ASSISTANCE” before returning thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only
Download Manual
LUXPRO PSDH021Wa NON-PROGRAMMABLE THERMOSTAT Installation Manual
Other manuals:
LUXPRO PSDH021Wa NON-PROGRAMMABLE THERMOSTAT OPERATING Manual
LUXPRO PSDH021Wa NON-PROGRAMMABLE THERMOSTAT Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…