Complete, Easy To Read Programming And Installation Instructions Inside
IMPORTANT!
Thank you for your confidence in our product. To obtain the best results from your investment, please read this manual and acquaint yourself with your purchase before installing
your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required for your particular installation. Please save it for future reference
CAUTION
Please read all instructions carefully before beginning installation.
TOOLS REQUIRED
Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations. follow the guidelines listed below.
MOUNTING THE PSD158 ON THE WALL
WARNING: Use Energizer® or DURACELL® Alkaline Batteries ONLY for all Lux thermostats requiring batteries
Hold the base against the wall, with the wires coming through wherever it is convenient for wiring. Route the wires to below the terminal block. Position the base for best appearance {to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided.
Caution
Do not allow wires to touch each other or parts on the thermostat. Wires must be trapped between the black spacer and the brass terminal. Also, be sure to tighten securely all 5 electrical terminalscrews
These diagrams are provided for new installations or unreferenced wires.
The PSD158 requires batteries to operate your furnace and retain its programming in memory and light the display. Replace the batteries when the BATT indicator appears in the display or at least once a year.
N O T E
When replacing batteries, you. have approximately 1 minute before programs are lost.
N O T E
If you have an electric system aJX1 the blower does not operate after installation, find ti electric/gas heat jumper on the back of the txxJy as indicated below. the jumper from the pins oo the far right to the pins on the far left.
TEMPERATURE SWING
A thermostat heating or cooling system is on and off whenever the room number of degrees from the set-point temperature. This variation is the “swing.· thermostat is tuned to provide you with exceptional comfort as well as provide you with energy savings. you desire to have the temperature control led even more lightly il your home at the expense of increased energy savings. you can change the Also users forced hot water systems may find these settings more comfortable. located on the bad< of the thermostat body are three jumpTo change horn 0.5 degrees F Marked button on the front of the thermostat with a paper clip for the change to take effect The unit will now control your home to 0.5
CHANGING FROM °F TO °C
MINIMUM ON TIME (5 MIN/2 MIN)
The thermostat has a built-in 5-minute minimum time to protect your system. If you find u, this is too long for your application (a zoned system is t)’typical example) you may change the delay to 2 minutes.
Do you have any problems installing or using this thermostat? please reread the instructions carefully technical Service is available through our Technical Service number. If you require assistance, please call Our offices between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday through Friday. The number is (856) 234-8803.
Limited VWaranty if this unit fails because of defects in materials or workmanship within one year of the date of original purchase. LUX at its option. repair or replace it. This warranty does not cover damage or accidents or misuse. or failure to follow installation instructions. implied warranties are limited in duration to one year from the date of the original purchase. SoTe states do not allow limitations on how long an implied warranty lasts. so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which the purchase was made. along with proof of purchase. Please refer to Technical Service Section before returning the thermostat. Purchaser assumes risk and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages. so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.
Download Manual:
LUXPRO PSD158 Digital Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…