WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc.
IMPORTANT!
Please read all instructions carefully before beginning installation and save them for future reference. Before removing any wiring from your existing thermostat, its wires must be labeled with their terminal designations. Ignore the color of the wires since they may not comply with any standard.
Thank you for your confidence in our product. To obtain the best results from your investment, please read this manual and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save it for future reference.
LUX PSDH121+ is designed for use with single-stage heat pump systems with auxiliary and/or emergency heat. These systems are typically known as 2-stage heat stage cool heat pump systems
Please read all instructions carefully before beginning installation. Turn off the electricity to the appliance before installing or servicing the thermostat or any part of the system. Do not turn the electricity back on until work is completed.
TOOLS REQUIRED
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below.
C A U T I O N
Read the instructions carefully before removing any wiring from the existing thermostat. Wires must be labeled before they are removed. When removing wires from their terminals, ignore the color of the wires since they may not comply with any standard.
REMOVING THE OLD THERMOSTAT
MOUNTING THE PSDH121+ ON THE WALL
N O T E
If you are mounting the base to a soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. Drill a 3/16- in. (4.8mm) hole at each screw location, and insert the plastic anchors provided. Then mount the base as described below.
ATTACHING WIRES
Route the wires through the large hole in the base plate by the terminal block. Hold the base against the wall, with the wires coming through. Position the base for the best appearance (to hide any marks from an old thermostat). The terminal block should be either to the right of or below the routing hole. Attach the base to the wall with the two screws provided.
N O T E
Install two AA batteries in the unit regardless if the C wire is connected to 24VAC. This will ensure that all MENU settings will be preserved during a power outage condition.
WIRING DIAGRAMS
These diagrams are provided for new installations or un-referenced wires.
NOTE: ADD JUMPER SHOWN BETWEEN “W2” AND “E” IF “E” IS NOT PRESENT
C A U T I O N
Do not allow wires to touch each other or parts on the thermostat. Terminated wires must be trapped between the black spacer and the brass terminal. Securely tighten all 8 electrical terminal screws.
JUMPER Settings
There are 2 Basics steps involving jumper settings:
HORZ: Sets the thermostat in a Horizontal orientation.
VERT: Sets the thermostat in a Vertical orientation.
Multiple Features can be accessed and selected by navigating through the MENU screen. The instructions below detail all the options under the
MENU screen:
Access the Menu Screen: In the off position, press Up and Down simultaneously (approx. 3 seconds) until the MENU screen is displayed
CALIBRATION
TEMPERATURE SWING
COMPRESSOR DELAY
FARRENHEIT AND CELSIUS
TEMPERATURE LIMITS
TEST MODE
This model is also known as Compressor Defeat. It allows the installer to operate the heating and cooling without any delays. Once entering this mode, the thermostat will automatically return out of the TEST mode in a 10-minute period. When the TEST mode is active, the temperature reading blinks as an indication of the TEST mode.
EXIT
When a low battery indication is displayed, proceed to replace the batteries immediately per the instructions below:
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from the date of the original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which the purchase was made, along with proof of purchase. Please refer to “TECHNICAL ASSISTANCE” before returning the thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.
TECHNICAL SERVICE
If you are experiencing any issues with the installation or usage of the thermostat, please feel free to call our Technical Support department at (856) 234-8803 or visit our website at
www.luxproproducts.com
Download Manual:
LuxPro PSDH121 DIGITAL ELECTRONIC Thermostat Installation Instruction
LuxPro PSDH121 DIGITAL ELECTRONIC Thermostat Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…