Model | WIN100 |
Problem | Resolution |
Indicates incorrect room temperature | Refer to thermostat manual to verify that your set temperature is what you expect it to be. |
Refer to your thermostat’s manual for calibration. Use this feature to adjust the displayed temperature up to +5°F(3°C) or -5°F(3°C) degrees. | |
Heats or cools more than 5 degrees past its displayed set temperature | Verify that the ON/OFF switch on the side of the unit is set to ON. |
Refer to thermostat manual to verify that your set temperature is what you expect it to be. | |
Refer to your unit’s manual to decrease the units swing value to a narrower setting. | |
Verify that your unit’s placement and mounting are reasonable per the installation section of it’s manual. | |
No heat or cooling when expected | Verify that the ON/OFF switch on the side of the unit is set to ON. |
Refer to thermostat manual to verify that your set temperature is what you expect it to be. | |
Operational Test | Set unit to heat mode. Adjust set temperature to at least 5 degrees below room temperature. Then adjust set temperature upward one degree at a time. Listen carefully for a soft click from the thermostat. This click should be heard near room temperature. Heat should operate immediately. |
Adjust set temperature down one degree at a time. Again listen carefully for a soft click from the thermostat near room temperature. Heat should switch off immediately. | |
Advanced Trouble Shooting | This thermostat is designed to switch hazardous voltage. Qualified service personnel may use the following information to trouble shoot the system. |
The WIN100 uses a normally-open single pole relay to control a heating or cooling appliance. | |
In heat mode it should open when hotter than its set temperature and close when cooler than its set |
temperature. | |
In cool mode it should close when hotter than its set temperature and open when cooler than its set temperature. | |
For further assistance: | Contact your HVAC service company or our Technical Assistance Line if not resolved. |
Model | WIN100 |
Problem | Resolution |
Display will not change | Peel protective plastic label from display. |
Display blurred and unreadable | Peel protective plastic label from display. |
Press the small round inset RESET button behind the door of your unit using a small Philips screw driver. Reconfigure and reprogram. | |
Time alternates with room temp | This is normal operation which can not be changed. |
Blank or fading display | Replace unit’s batteries with fresh Duracell® or Energizer® G13A alkaline batteries. Be sure that they are installed with their polarity (+ and -) correct. |
Clean battery contacts with a pencil eraser and pry out the spring contact slightly to insure a clean, firm connection. | |
Press RESET using a small Philips screw driver. Then reconfigure and reprogram. | |
Displays “LO BATT”, “REPLACE”, or battery symbol | Replace batteries with fresh G13 size Duracell® or Energizer® alkaline batteries. Be sure that they are installed with their polarity (+ and -) correct. |
Displays wrong room temperature. | See Temperature Regulation |
You want to change the displayed temperature scale from °F to °C or from °C to °F | Rotate the Speed Dial® to “SET WEEKDAY PROGRAM”. Press “HOLD” and “NEXT” simultaneously to change the displayed temperature scale. from °F to °C or from °C to °F. Rotate dial back to RUN. |
You want to change clock | Most LUX electronic thermostats can display time in |
format from 12Hr Standard Time to 24Hr Military Time or from 24Hr Military to 12Hr Standard Time | 12HR (AM/PM) or 24HR military time. The WIN100 model thermostat does not have this particular option for the clock. |
Displays wrong day or time | Rotate the Speed Dial® to “SET DAY/TIME”. The day will flash, use UP key to correct day. Press NEXT. The time will flash. Use UP and DOWN keys to set the correct time. Rotate dial back to RUN. |
Displays no set temperature | Refer to model specific troubleshooting or your owners manual. |
Shows “888” on display | Press RESET using a small Philips screw driver. Then reconfigure and reprogram. |
Shows “OL” | “OL” means Out of Limits. The sensor is reading outside the thermostats display limit of 32°F to 95°F. When the temperature returns to within these limits the temperature display will reappear. If actual room temp is not outside these limits, there may be a malfunction. Press the small white HW RESET button on the circuit board. Reconfigure and reprogram. |
Displays “OVERRIDE” | “OVERRIDE” appears on the display when the set temp is raised or lowered from the programmed temperature. Overrides are terminated at the next scheduled program period when the unit will revert to the programmed temperature and the “OVERRIDE” will be extinguished. |
For further assistance: | Contact your HVAC service company or our Technical Assistance Line if not resolved. |
Download Manual: Lux WIN100 Serrie Smart Temp Electronic Thermostat Support Guide
Other Manuals:
Lux WIN100 Serrie Smart Temp Electronic Thermostat INSTALLATION and Operating MANUAL
Lux WIN100 Serrie PA-19112 Smart Temp Electronic Thermostat INSTALLATION and Operating MANUAL
Lux WIN100 Serrie Smart Temp Electronic Thermostat Support Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…