WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only
Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc.
Complete, Easy To Read Programming And Installation Instructions Inside
IMPORTANT!
READ INSTALLATION INSTRUCTIONS FIRST
Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save it for future reference.
CAUTION
CAUTION: To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the fuse box, at the circuit breaker, or at the appliance.
Please read all instructions carefully before beginning installation.
TOOLS REQUIRED
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below.
REMOVING THE OLD THERMOSTAT
Switch the electricity to the furnace and air conditioner OFF; then proceed with the following steps.
CAUTION
Read the instructions carefully before removing any wiring from the existing thermostat. Wires must be labeled before they are removed. When removing wires from their terminals, ignore the color of the wires since these may not comply with the standard.
MOUNTING THE TX1500 ON THE WALL
CAUTION
Be careful not to drop the body or disturb electronic parts.
Leave the cover closed while the body is being removed from the base.
NOTE
If you are mounting the base to a soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. Drill a 3/16-in. (4.8mm) hole at each screw location, and insert the plastic anchors provided. Then mount the base as described below.
ATTACHING WIRES
Hold the base against the wall, with the wires coming through wherever it is convenient for wiring. Route the wires to below the terminal block. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided.
CAUTION
Do not allow wires to touch each other or parts on the thermostat. Wires must be trapped between black spacer and brass terminal. Also, be sure to tighten securely all 7 electrical terminal screws.
NOTE: If you have an electric system and the blower does not operate after installation, find the electric/gas heat selector on the back of the body. Move the selector to the ELEC position.
INSTALLING BATTERIES/ MAINTENANCE
The TX1500 requires batteries to operate your furnace and retain its programming in memory and to light the display. Replace the batteries when the REPLACE indicator appears in the display or at least once a year.
NOTE: When replacing batteries, you have approximately 1 minute before programs are lost.
TECHNICAL SERVICE
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance Department at 856-234-8803 during regular business hours between 8:00 AM and 4:30 PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproducts.com. Our website offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX Products Corporation will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from the date of the original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which the purchase was made, along with proof of purchase. Please refer to “TECHNICAL ASSISTANCE” before returning the thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.
NOTE: The FAN switch works only if your system provides a wire for the TX1500’s “G” terminal.
THE BUILT-IN ENERGY STAR® PROGRAMS
Push in the RESET key. This sets the built-in heating and cooling programs. To review the built-in programs, rotate the dial to SET WEEKDAY / SATURDAY / SUNDAY PROGRAM.
You can use the built-in programs as shown, or change them as you wish. Each day is divided into four periods. Each period has its own starting time and temperature.
The dial must be in the RUN position to close the door.
PERIOD | HEAT | COOL | |
WEEKDAYS preprograms | MORN DAY EVE NIGHT | 6:00 AM 70° 8:00 AM 62° 6:00 PM 70° 10:00 PM 62° | 6:00 AM 78° 8:00 AM 85° 6:00 PM 78° 10:00 PM 82° |
SAT & SUN preprograms | MORN DAY EVE NIGHT | 6:00 AM 70° 8:00 AM 62° 6:00 PM 70° 10:00 PM 62° | 6:00 AM 78° 8:00 AM 85° 6:00 PM 78° 10:00 PM 82° |
PROGRAMMING THE TX1500
You can change any preset times and/or temperatures to suit your schedules for the weekday, Saturday and Sunday programs. Each period (Morning, Day, Evening, and Night) is programmed for HEAT and for COOL.
Select HEAT to program the TX1500 for controlling your heater.
OR
Select COOL to program the TX1500 for controlling your air conditioner.
Rotate dial to SET WEEKDAY PROGRAM. To program SATURDAY or SUNDAY, rotate the dial to SET SATURDAY or SET SUNDAY PROGRAM. With dial on SET WEEKDAY PROGRAM, you will see the display above.
SETTING THE TIME AND DAY
CAUTION
The TX1500 is protected against normal static electric discharges. However, in extremely dry weather you should touch another metal object before the TX1500 to avoid potential loss of programs.
Open the drop-down door on the front of the thermostat. Rotate the dial to the SET DAY/TIME position. You should see the display pictured above with a day of the week flashing. When you are finished setting the day and time, rotate the dial to RUN to return to normal operation or to another position to continue programming.
TEMPERATURE OVERRIDE AND TEMPERATURE HOLD
These features let you change the current Set Temperature without changing the programs stored in your thermostat’s memory.
TEMPORARY TEMPERATURE OVERRIDE
VACATION TEMPERATURE HOLD
FILTER USAGE MONITOR
The FILTER Monitor counts the hours since the filter in your blower was last changed. After 250 hours of use, FILTER will appear in the display. After you change the filter, set the thermostat’s FILTER Monitor back to zero as follows.
To disable the FILTER Usage Monitor set the limit to 0 hours
TEMPERATURE SWING
A thermostat works by turning your heating or cooling system on and off whenever the room temperature varies a certain number of degrees from the set-point temperature. This variation is the “swing.”
Your system should cycle on about 3 to 6 times per hour. A smaller swing number increases the number of cycles, so room temperature is more constant. A larger swing number decreases the number of cycles, to save energy in most cases.
SWING SETTINGS
TEMPERATURE CALIBRATION
PROGRAM LOCK
To prevent tampering with set programs.
The sequence of keys to lock and unlock the program:
WARNING: Making these changes will require you to reset the thermostat. Copy any of your customized programs onto the blank chart. This will be your reference to re-enter the programs afterwards.
CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK
5 MIN/2 MIN MINIMUM ON/OFF TIME
Your thermostat has an internal timer built in to protect your compressor. The timer forces a minimum on/off time of 5 minutes. You may change this minimum on/off time to 2 minutes. To accomplish this, remove the jumper labeled 5/2 MIN. You must press the small reset button on the face of the thermostat for the changes to take effect.
Download Manual
Lux TX500B PROGRAMMABLE Troubleshoot Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…