The ComfortSense® 5500 Series thermostat is an electronic 7-day, single-stage, programmable, touchscreen thermostat. Features are:
Press the screen anywhere – the first press turns on the backlight.
Table 1. System Status Icons
Press anywhere in the area indicated below to select how the system will operate.
In the CIRCULATE mode, the user can cycle the fan for a programmed period time of active time per hour during periods of equipment inactivity (i.e., heating or cooling equipment not running).
| on | Fan is NOT following the schedule and runs continuously until it is changed from the select mode. |
| auto | The fan will follow the fan set ting in the selected sched ule. |
|
circu late | Fan is following schedule and cycles during periods of equipment inactivity. Circulate off time is dependent on user settings. |
When a system error or reminder occurs, a pop-up screen will appear indicating the condition.
PERFORMANCE REPORT
This will display the total number of hours each month that the system has been running. An example would be for mar (March) 23H or 23 hours. To return to the menu screen, press the house icon in the upper left-hand corner of the screen.
EDIT SCHEDULES
NOTE: See Selection Mode on page 9 to run a specific schedule.
From the HOME screen press the MENU and press the edit schedules option.
The edit schedules screen will allow sections of up to three separate schedules. On the edit schedules screen, each schedule can be renamed and edited. See Figure 7 for editing schedules.
NOTE: If a fan mode is selected under the select mode screen, it will override any fan setting in individual schedules.
< | edit schedules | |
schedule 1 | > | |
schedule 2 | > | |
schedule 3 | > | |
add schedule |
SETTINGS (USER)
Table 3. User Settings (Fan)
Setting Selection | Function | Description |
fan | on, auto, and circulate | See table for a detailed description. |
Table 4. User Settings (Heat/Cool or Cool Only)
Setting Selection | Function | Description |
heat/cool (gas or electric heat ing is selected) | normal | Heats home to desired tempera true setting. Options are on or off. |
setpoint range | Heating limits with a default of 90°F. The range is 45°F to 90°F Cooling limits with a default of 45°F. The range is 45°F to 99°F | |
cool only (option only appears if no heating equipment is avail able or configured) | setpoint range | Cooling limits with a default of 45°F. Range is 45°F to 99°F |
reminders | Select reminders. The reminder setting screen will appear and a list all of the predefined reminders plus the two custom reminders at the end of the list. NOTE: Your installer will need to change the name of the two available custom reminders. Select the desired reminder to set a date. By default all reminders are set to disable. Press disable for a specific reminder to choose from 3mon, 6mon, 12mon, 24mon or custom date. When finished, press < to return to the previous menu. |
Table 5. User Settings (General)
Setting Selection | Function | Description |
general – provides information about the thermostat and settings for screen lock, date & time and language. | about | Displays information concerning thermostat model number, serial number, hardware and software revisions. |
screen lock | Setting options are unlocked, partially, and locked. To set the partial lock, create a three-digit code. Partially locked restricts access to the menu. To set locked, create a three-digit code. Lock restricts access to anything on the screen. NOTE: Partially Lock and Locked is set for one instance only. Either would need to be set each time it is desired to be partially locked or locked the screen. The master code is 864 in case the user forgets their custom code. | |
date & time | Settings for 24-hour clock (military), daylight savings, set time and date. | |
language | Languages available are English, Spanish, Portuguese and French. |
Table 6. User Settings (Display)
Setting Selection | Function | Description |
display – Allows the user to control some information that is displayed on the home screen. | screen saver | Options are enabled and disable. Default is enabled. When enabled only the time and inside temperature is displayed on the screen. Touching the screen will restore all other details. The backlight setting is also on the same screen. Options are continuous on or energy savings. The default is continuous on. |
screen brightness | A horizontal adjustment bar is provided to move from minimum to maximum brightness. | |
temperature scale | °F for Fahrenheit or C° for Celsius. | |
clean screen | This will disable the touchscreen for 30 seconds. |
Download Manual
Lennox ComfortSense 5500 Programmable Thermostat User Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…