Read this manual carefully and keep it with other warranty documents. The connection must be carried out by a qualified installer in accordance with local regulations. Before installing or disassembling the thermostat, always switch off the electricity in the meter cupboard. This thermostat can be installed in a single flush-mounting box 50 mm deep, according to standard DIN formats.
Order Heating wire 1 and 2 does not apply.
EARTH: Connect the earth of the heating cable and the earth of the power supply outside the thermostat.
Choose mode
ATTENTION
(Thermostat on) Long press o to enter options
There are 3 periods (6 setpoints) per day. See the standard scedule for reference:
Wake up (On) | Away (Off) | Home (On) | Away (Off) | Home (On) | Sleep (Off) | ||||||
Setpoint 1 | Setpoint 2 | Setpoint 3 | Setpoint 4 | Setpoint 5 | Setpoint 6 | ||||||
06:00 | 20oC | 08:00 | 15oC | 11:30 | 20oC | 13:30 | 15oC | 17:00 | 20oC | 22:00 | 15oC |
Advanced settings A
WARNING: Changing advanced settings may cause undesired results. Please consult your installer before entering this menu!
No. | Item | Parameters | Default |
A1 | Measured temp. calibration | -9oC to +9oC | -1 oC |
A2 | Differential | 0.5oC to 2.5oC | 1oC |
A3 | Key lock | 0: Half lock 1: Full lock | 0 |
A4 | Power with memory function | 0: Power with memory function 1: Shutdown power after power off 2: Shutdown power after power on | 0 |
A5 | Backlight time | 5 to 30 seconds | 10 sec |
A6 | Programmable | 0: 5+2 (Week 1-5 and weekend 6-7) 1: 6+1 (Week 1-6 and sunday 7) 2: 7 (Week 1-7) | 0 |
A7 | Lowest temp. setting | 1 – 10oC | 5oC |
A8 | Highest temp.setting | 20-70oC | 35oC |
A9 | Low temp.protection | 1: 1oC – 10oC Function off: > 10oC Display (—– ) | 5oC |
AA | High temp.protection | 1: 35oC-70oC 2: Function off: < 35oC Display (—- ) | 45oC |
AB | High temp. protection differential | 1-9 | 2 |
AC | Running temp. of open window function | 1: 10 – 20oC, 2: Function off: < 10oC Display (—- ) | 1 |
AD | Running time of open window function | 10 – 20 min | 10 |
AE | Reset to factory settings | Long press o until display goes blank | – |
Advanced settings B
No. | Item | Parameters | Default |
BN | Options of sensor | N1 : Built-In Room sensor N2: Floor sensor N3: Built-In Room sensor with floor sensor as limiter | N1 (Change to N2 when using floor sensor with underfloor heating.) |
BC | Descaling | 0: Disable descaling function 1: Enable descaling function | 0 |
Bo | Product information | Can’t be changed | – |
Return difference
The room sensor has a max temperature of 45 degrees as a factory default. When the max temperature for the room sensor reaches 45 degrees and goes above this temperature, then the underfloor heating will switch off and an audible alarm will sound, the alarm will not turn off until the room sensor goes below 43 degrees.
Sensor Error Codes
When the error code “E1” shows up on the controller it indicates a room sensor failure or if the “E2” error code shows up on the controller it indicates a floor sensor failure. The thermostat will not heat until the error code is fixed.
Download Manual:
klima SF300 Digital Thermostat Operating Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…