DANGER! ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS, AND SAFETY DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURY
WARNING READ CAREFULLY – These instructions will help prevent difficulties that might arise during thermostat installation. Studying the instructions first may save considerable time and money later. Observing the following procedures will keep installation time to a minimum. Save these instructions for future use.
K701-1-DTSB Autonomous Dual Timed Setback is designed to be used where an Automatic timed electric heat setback is needed and a second lower setback for longer away times. This is typically used in College dormitories, Motels, and Temporary housing, and anywhere the tenant is not finically responsible for the cost of heating and has an active life pattern. This guarantees and reinforces good energy-saving habits and places the burden on the Tenant for the higher heating levels and their efforts to remain above a predefined reasonable and typically comfortable level.
Be safe and smart, electricity can cause severe injury or death. If you are uncomfortable hire an electrician for the project This Autonomous Dual Timed Setback is for small fan electric heaters, baseboards, radiant ceilings, wall panel heaters, cove heaters, or any 120 Line voltage resistance heating systems that do not have an electric motor over 1/3 hp. The thermostat will be warm to the touch on top. This is normal operation and also provides air currents across the face of the thermostat that better help it sense room temperature.
Features of Front Display and Controls
Wiring Requires a Phillips Screwdriver
Operation Instructions
Manual Temperature Adjustment Range: 55°-74°F (13-23°C)
Display Temperature Offset Compensation:
In unusual cases, your Autonomous Dual Timed Setback may register “Room Temperature” higher than the actual temperature is. You can adjust the registering value by using the Temperature Compensation value.
NOTE: The TimerStat can only adjust the displayed temperature compensation downward by up to 18° F/10°C.
Reset Your Autonomous Dual-Timed Setback:
In case your thermostat is not functioning correctly, (possibly due to a static charge) you can reset the unit back to the factory settings. Locate the RESET button on the right side of the unit, lightly press the button with a pointy object and the unit will reset.
Autonomous Dual Timed Set Back
Timed comfort where the burden in on the tenant to maintain their set point. Where the Landlord is providing comfortable heating and the tenant is responsible for maintaining the set point. Typical uses are Dormitory, Public or temporary housing applications. Public bathrooms, Motel and Hotel applications, or anywhere a guaranteed setback is required not based on time of day.
Manual Programming of Jumpers JP1,2,3,4:
Manual Temperature Adjustment Range: 55-74°F (13-23°c)
If no jumpers are added the Default temperatures and times are followed.
The sequence of Operation of the thermostat in the Default setting.
Tenant sets the thermostat to 70°F/21°C for Comfort: After 2 hrs. Minor set back drops the temperature to 66°F/19°C.
If the tenant doesn’t increase the temperature after 48 hrs. thermostat will drop to 55° F/13°C. The tenant may increase the temperature at any time but will continually reset the timing but will eventually set back to guaranteeing energy savings.
FOR INDOOR USE ONLY
KING ELECTRICAL MFG. CO. 9131 10TH AVENUE SOUTH SEATTLE, WA 98108
PH: 206.762.0400
FAX: 206.763.7738
www.king-electric.com
DOWNLOAD MANUALS:
King Electric K701-1-DTSB AUTONOMOUS DUAL TIMED STAT Electronic Thermostat Installational Manual
King Electric K701-1-DTSB AUTONOMOUS DUAL TIMED STAT Electronic Thermostat Installational Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…