WARNING READ CAREFULLY
These instructions will help prevent difficulties that might arise during thermostat installation. Studying the instructions first may save
considerable time and money later. Observing the following procedures will keep installation time to a minimum. Save these instructions for future use.
This Thermostat has been designed to control fan-forced and radiant line voltage electric heaters.
The ClearTouch K322E combines user-friendly touch-sensitive buttons with a sleek modern design. Offering simple non-programmabe control of your comfort.
INSTALLATION INSTRUCTIONS
The installation of the thermostat must comply with the applicable local and/or national electrical code and utility requirements. This installation should be performed by a qualified electrician where required by law. Ensure that all wiring connections to the thermostat are correct and tight to prevent electrical shorts. Use the appropriate wire to meet local and national electrical codes for rated power consumption.
WARNING!
Warning Turn OFF the power at the circuit breaker before Installing. Installation is to be performed by a qualified electrician or authorized technician.
Refer to thermostat and heater load specifications before installation of the thermostat to see if it can handle the amp load. The maximum this thermostat can run is
1800W@120V or 3600 W@ 240 V (15A). Install the unit in a grounded metal or plastic wall junction box, indoors 4 %’ to 5″‘ above the floor. Avoid any area where it
can come in contact with external sources of heat and cold. This includes plumbing pipes, direct sunlight, a T.V. set, lamps, and drafts from a door or window, as this
may cause inaccurate temperature readings. The most convenient place is above the light switch. Not for Outdoor use.
Caution: Turn off the power at the circuit breaker before performing any work on the electrical connections. None of the electrical connections must be live until the install-
Latin has been completed and the housing is closed. Only a qualified electrician or authorized technician is permitted to open the terminal box.
Wiring requires a Phillips screwdriver
Safety Information:
Setback: This is an input signal driven by a remote contact. One terminal connects to the internal power source by 10K resistance; another terminal connects to the internal ground. The circuit diagram is shown on the left.
Relout: This is an output allowing the remote control of a series of Slave Re- lays (K312RELAY). Inside the thermostat is an open drain circuit, driving a 24V relay. The maximum drive current is 30 mA. The circuit diagram as shown on the left. Tnis is Used to connect to a Slave Relay (K312RELAY) to expand the heating Surtace. Multiple Slave Helays can be interconnected in a daisy chain, see below
Master/Slave Wiring Diagram
In any mode, press
Keypad Lock
In the normal working interface, press
When the keypad is locked, no adjustment is possible. When the icon of the Keypad Lock
Room Temperature Control Mode
When the icon
will be turned on, and the icon
Remote Control of Thermostat
When there is a remote control signal input, the Remote icon (bar) blinks; when the detected indoor temperature is below the set temperature by-2°C(-4P), electrical heating will be turned on, and the icon
Sensor Failure
When the sensor fails to work, the error icon EEE will be displayed on the screen. The output relay will open. Heating output will stop. Replace sensor.
Configuration of User Parameters (Hidden Menu)
When the thermostat is OFF: Press and hold the CONFIRM button to enter into the seting interface. Default values and options are defined below:
KING ELECTRIC MFG CO 9131 10TH AVENUE SOUTH SEATTLE, WA 98108-
PH:206 762 0400-
FAX: 206 763 7738
www.king-electric.com
DOWNLOAD MANUALS:
King Electric K322E Electronic Non-Programmable Thermostat Installational Instruction
King Electric K322E Electronic Non-Programmable Thermostat Installational Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…