ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS, AND SAFETY DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURIES
READ CAREFULLY – These instructions will help prevent difficulties that might arise during installation. Studying the instructions first may save considerable time and money later. Observing the following procedures will keep installation time to a minimum. Save these instructions for future use.
FUNCTIONS AND FEATURES
This Slave Relay has been designed for heating applications that exceed 15 amps.
The K312RELAY output board is a new intelligent product for temperature control. It can control a heating load 120V/240V in accordance with the main thermostat input signal. It is accurate and sensitive with high reliability and performance. This remote module will function only if connected to a thermostat K302PE Master Thermostat.
DANGER
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS, AND SAFETY DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURYThe installation of the thermostat must comply with the applicable local and/or national electrical code and utility requirements. This installation should be performed by a qualified electrician where required by law. Ensure that all wiring connections to the thermostat are correct and tight to prevent electrical shorts. Use the appropriate wire to meet local and national electrical codes for rated power consumption.
WARNING!
Warning: Turn OFF the power at the circuit breaker before Installing. Installation to be performed by a qualified electrician or authorized technician. Refer to thermostat and heater load specifications before installation of the thermostat to see if it can handle the amp load. The maximum this thermostat can run is 1800W @120V or 3600 W@ 240 V (15A). Install unit in a grounded metal or plastic wall junction box, indoors 4 ½’ to 5′ above the floor. Avoid any area where it can come in contact with external sources of heat and cold. This includes plumbing pipes, direct sunlight, a T.V set, lamps, and drafts from a door or window, as this may cause inaccurate temperature readings. The most convenient place is above the light switch. Not for Outdoor use.
Caution: Turn off the power at the circuit breaker before performing any work on the electrical connections. None of the electrical connections must be live until the installation has been completed and the housing is closed. Only a qualified electrician or authorized technician are permitted to open the terminal box.
Wiring requires a Phillips screwdriver
Connection to the Master Thermostat (K302PE)
Connect the low voltage wire from the master thermostat (K302PE) into terminal no. 3 & 4 on the back of the power board and tighten the screws with the screwdriver provided in the box. If required: To add an additional Slave Relay, connect the low voltage wire from the second Slave Relay to terminals no. 5 & 6 (Report) on the back of the power board and tighten the screws with the screwdriver provided in the box. See the below diagram. Install the power board into the electrical box with the 2 screws provided, and then clip & fasten the front Display Panel into place with the bottom screw Make sure your K302PE thermostat is COMPLETELY RECESSED into the junction box and flush with the wall. NO WIRES SHOULD BE EXPOSED outside the metal or plastic junction box.
Safety Information
Wiring Instructions
Test Button
If there is no remote control signal from the main thermostat, press and hold the TEST button to perform an electrical function test loop of the heating relay. During or after the test loop, press the Reset/Test button again to resume normal operation.
Press and hold the TEST button. The power indicator light will blink, the electric heating indicator light turns on, and the heaters turn on as the signal of Relout begins to output. Press and hold the TEST button again (or automatically after 30min), and the device will exit the test, and the heater powers off.
Remote Signal Control
When the terminal of Setback detects an input signal from the master thermostat, the indicator light of electric heating turns on, and the heater turns on as the signal of Relout begins to output. After 30min, the heater will power off automatically.
Note: Remote Signal Control has the highest priority. Remote Signal Control has the highest priority.
King Electric K312RELAY Clear Touch thermostat Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…