KETOTEK KT3200 Plug-In Thermostat Day Night Temperature Controller
Introduction
The KT3200 temperature controller displays the measured temperature, and set the start and stop temperature to control the heating or cooling equipment. It also has time function to set day and night temperatures independently. It is widely used in intelligent control such as heating, refrigeration, and brewing. reptile, aquaculture, greenhouse, home life and many other places.
Warning
- Before you use this unit, check on the plastic shell. Do not use it if there is any damage.
- The output is max 15A. Please use a resistance load of less than 15A.Inductive load less than 2A.
- Do not use this unit in an environment of explosive gas, steam or dust.
- Do not allow children to operate the device.
- Do not disassemble the device by yourself.
Specifications
- Power Supply: 100-250Vac 50/60hz
- Temperature control range:-72-176°F /- 40-120°C
- Setting Time: 0-24h / Daily cycle timer
- Control accuracy: t1°F /£1°C
- Sensor: NTC10K 3m
- Output: Max 15A/120OV US plug
- Working Mode: M1 M2 M3 can be choose
M1 TC temperature control mode
- Press to choose M1 TC.the KT3200 will work in temperature control mode. Long press to switch C/°F
- Press to select each digit. Press to adjust the start temperature and stop temperature.
Heating mode:
- When you set start temperature stop the temperature. The KT3200 will work in heating mode. LCD screen display Heater connected to the output. Heater work when measured temperature < start temperature,LED indicator lights up.
- Heater stop when measured temperature 2 stop temperature, LED indicator lights off.
- For example, set start temperature to 68°F.stop temperature to 77°F. heater work when measured temperature< 68°F. The heater stop when the measured temperature was 277°F.
Cooling mode
- When you set start temperature > stop temperature. The KT3200 will work in cooling mode. LCD screen display.Cooler connected to the output. Cooler works when measured temperature> start temperature, LED indicator lights up.
Cooler stop when measured temperature < stop temperature, LED indicator lights off. - For example, set the start temperature to 77°F.stop temperature to 68°F.Cooler works when measured temperature> 77°F. Cooler stop when measured temperature 68°F
M2 TC+Timer Day/night temperature control
- Press to choose M2 TC+Timer.KT3200 will work in day/night two-time period temperature control mode. Screen displays real-time temperature and clock in turn. and current time temperature control program.
- You can set Clock, Time1, Time2, TC1, and TC2.In every 24 hours, Day time(Time1-Time2) run the TC1 program. Night time(Time2-Time1) run TC2 program.
- Press to go into the setting. Press to select the next digit. Press return one digit. Press to adjust the value. Press (Mto switch to seting page2-3.
M3 Timer 2 time period timer only
M3 Default settings
Temperature Calibration
In power off state,Press and hold (M) to plug KT3200 into power outlet, the screen will display 0.0 and flash. Press to adjust the value in range-9.9-9.9 C.Press and hold () to save and exit.
Reset
Press seconds to restore the factory setting.
Switch CIF
Press 3 seconds to switch C/F.
Memory function
- All data except the clock will be saved after power failure.
- The clock needs to be reset when powered on.
- If KT3200 works in M1 mode before power failure, it will automatically resume operation after power on again.
- If KT3200 work in M2 or M3 mode before power failure, you will need to reset the clock first when power is on again.
REFERENCE
Download Manual:
KETOTEK KT3200 Plug-In Thermostat Day Night Temperature Controller Instruction Manual
KETOTEK KT3200 Plug-In Thermostat Day Night Temperature Controller Instruction Manual