When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.
For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com where you can download the relevant information in PDF format.
This kit is suitable only for the domestic gas boilers listed below:
The national regulations and respective safety instructions are to be observed. Interferences and changes to the device will lead to cancellation of the warranty.
The RF Electronic Programmable Room Thermostat features the following:
Note. If a battery symbol is blinking, the display is blinking or the display is blank then replace batteries.
(BOILER MOUNTED)
Note. Summer/Winter time automatically updated.
Note. It is also possible to change the Room Temperature Set Point just by pressing the
SETTING THE RF PROGRAMMABLE ROOM THERMOSTAT TO RUN IN AUTOMATIC MODE
(using the programmed on and off times)
SETTING THE RF PROGRAMMABLE ROOM THERMOSTAT TO BE CONTINUOUSLY ON
SETTING THE RF PROGRAMMABLE ROOM THERMOSTAT TO BE CONTINUOUSLY OFF
Note. Use of the ‘+ Hours’ function will ensure the boiler operates continuously for up to 5 hours. If used during an off period, the boiler will then operate for up to 5 hours.
If used during an on period less than 5 hours prior to an off period, it can extend the on time.
A. HOLIDAY MODE
B. TIMED PRE-HEAT
When Domestic Hot Water preheat is switched on the boiler control the boiler will preheat from the beginning of the first timed on central heating period of the day to the end of the last timed on central heating period of the day, so as to provide more efficient water delivery. This function is disabled when the preheat switch is set to off.
C. OPTIMISATION
This feature provides for greater comfort and economy of operation. The boiler will be switched on earlier than the programmed heating on time. This provides for the room temperature to be achieved at the programmed heating on time, rather than some time afterwards. The boiler will automatically only use the minimum energy required in order to achieve the desired room temperature.
To set an optimisation period, press the ‘Copy’ and ‘Next Day’ keys together for more than 3 seconds. Note that the programmed heating on time should be set for when the house is required to be at the set temperature and not to allow for warming up of the property. The optimisation can then be set between 10 and 60. (Note that 00 = OFF)
It is advised that a setting between 10 and 30 should be used, to ensure the central heating does not switch on earlier than desired. This number is multiplied by the difference between the actual temperature and the desired temperature to determine what time before the start of the 1st on period the heating should be switched on.
EXAMPLE 1:
If the optimisation period is set to 10 and the desired room temperature is 20ºC at 6am and the actual room temperature is 19ºC then the central heating will switch on (20-19) x 10 = 10 mins early (i.e. at 5.50am)
EXAMPLE 2:
If the optimisation period is set to 30 and the desired room temperature is 20ºC at 6am the actual temperature is 16ºC then the central heating will switch on (20-16) x 30 = 2 hours early (i.e. at 4.00am)
D. ENGLISH LANGUAGE ERROR DESCRIPTION
Boiler fault codes are identified on the display in plain English.
LOGIC C | ROOM STAT / LOGIC + / VOGUE C GEN 2 |
L1 | OVERHEAT LOCKOUT |
L2 | IGNITION LOCKOUT |
L6 | FALSE FLAME LOCKOUTS |
L6 | TOO MANY REMOTE RESETS |
F1 | LOW WATER PRESSURE |
F2 | IGNTION FAULT |
F3 | FAN FAULT |
F4 | FLOW THERMISTOR FAULT |
F5 | RETURN THERMISTOR FAULT |
F6 | OUTSIDE SENSOR FAULT |
F7 | LOW MAINS VOLTAGE |
n/a | HIGH MAINS VOLTAGE |
FA | FLOW/RETURN REVERSED |
FU | HIGH FLOW RETURN DIFFERENTIAL |
n/a | THERMAL FUSE LOCKOUT |
n/a | NO WATER FLOW FEEDBACK (PUMP) |
n/a | PUMP ROTOR BLOCKED |
n/a | PUMP LOW VOLTAGE FAULT |
For further information refer to boiler User Guide.
E. OPENTHERM
The unit uses the OpenTherm protocol to control the boiler flow temperature set point in central heating operation. This means that the boiler will run in its most efficient manner and offer significant savings in energy over standard room thermostats. It will also give more accurate and comfortable temperature control in the room where it is installed.
If the room temperature is close to its setpoint then the pump may run for extended periods without switching the burner on. This is normal operation which reduces gas consumption whilst maintaining the desired room temperature.
F. BUILT IN FROST PROTECTION
If the temperature in the room falls below 5ºC, the boiler will fire to maintain the minimum 5ºC setpoint regardless of whether the timer is in an “off” period or not.
G. LOCKOUT RESET
If the boiler is at lockout (OVERHEAT LOCKOUT, IGNITION LOCKOUT, NO WATER FLOW LOCKOUT, or LOCKOUT 6) it is possible to reset the lockout from the programmable room stat by pressing the
The unit required 2 x AA 1.5V Batteries.
Batteries should operate for approximately 18 months.
Only good quality 1.5V alkaline batteries should be used. DO NOT use re-chargeable batteries as they only have a terminal voltage of 1.2V nom.
To replace batteries remove battery panel on the front of the room thermostat to gain access.
Note that if the batteries are removed for more than 30 seconds, the time, date, and set temperature will be lost.
If the batteries are not replaced and no signal is received by the receiver all 5 lights on the receiver on the boiler will flash on and off.
After 1 hour the boiler will operate in “Emergency Mode” with a continuous, but reduced temperature until the batteries are replaced.
Waste Electrical and Electronic Equipment Directive
Ideal Boilers Ltd., P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration No. London 322 137.
Ideal Boilers Ltd., pursues a policy of continuing improvement in the design and performance of its products.
The right is therefore reserved to vary specification without notice.
Download Manual:
RF_Electronic_Programmable_Room_Thermostat_User_Guide
IDEAL HEATING RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT User Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…