LCD symbols

LCD symbols
Icon Legend
The buttons are locked
The heating is turned on
Frost protection activated
AUTO Automatic mode executes the programmed schedules
Override Temporary temperature override
Er The floor sensor is not being read by the thermostat

Program

Setting the clock and day of the week

This thermostat is fitted with a real-time clock. It is essential that the clock time and day are set accurately if you require your programmed events to start on time. To set follow the steps below:

  1. Touch the “Time” and the time will start flashing. Use the up and down arrows to set the time. By holding the arrow down the time will change faster.
  2. Touch the “Day” and then press the + or – buttons to adjust. Sunday is day “1”
  3. Press DONE to store and exit.

Setting the Programme Schedules

  • This thermostat has the ability to programme each individual day of the week separately, or program 7 days of the week at once.

Programming your Thermostat

This section will help you programme your thermostat automatically. If you want to simply turn it on and off when required skip this section.

  1. Press Set Schedule The current Day will flash. Press “All Days” to set the same heating schedule for every day. Or press next to set each day differently.
  2. Press NEXT and Program 1 is displayed. This is the first programme function of the day.
  3. The time is now flashing. Select the time you want the heating to come on in the morning. Then press next.
  4. The temperature is now flashing. Set the temperature that you want the floor to heat to. Then press next.
  5. The LCD screen will show programme 2 Program 2 and the time will be flashing. This is the time that the thermostat will switch off in the morning.
  6. Press NEXT and the temperature will start flashing. This can be used to maintain a minimum temperature. In most cases this is not required and the temperature should be set to 5.
  7. Press NEXT and the Program 3 icon will display. The time is also flashing. Set the time at which you want the heating to come on in the afternoon or evening. NOTE: If you do not wish the heating to come in the afternoon, simply set the “off” time for only a couple of minutes after the “on” time.
  8. Press NEXT and set the temperature required in the afternoon.
  9. Press NEXT and the LCD screen will show programme Program 4 This is the time that the thermostat will switch off in the afternoon/evening. Press NEXT and set the temperature. As per above we recommend 5. Then Press DONE.

(*). Hint: If you are programming each day differently the above will need to be repeated for each day.

Default Programming is as follows

Programme Start Time Setpoint Explanation

01

WAKE 07:00

22 °C

This is the time the heating will come on in the morning.

02

LEAVE 09:30

16 °C

This is the time the heating will switch off in the morning. It can also be used to set a minimum temperature for the day.

03

RETURN 16:30

22 °C

This is the time the heating will come on in the afternoon.

 

04

 

SLEEP 22:30

 

16 °C

This is the time the heating will switch off in the afternoon/evening. If you do not require the heating in the afternoon/evening, simply set this time to a couple of minutes after the “on” time.

Installation and Wiring

Carefully separate the front half of the thermostat from the back plate by unscrewing the small screw at the bottom of the thermostat. Carefully unplug the ribbon connector which is plugged into the front half of the thermostat. Place the thermostat front half somewhere safe. Terminate the thermostat as shown in the diagrams below.

Screw the thermostat back plate onto the flush box

  • Re-connect the thermostat ribbon cable and clip the two halves together.
  • Connect green wire from the element to the house earth.

Warning: This product should be installed by a qualified electrician.

Manual Mode
Press HEATING MODE to select Auto/Manual mode. In Manual mode, the thermostat maintains a constant set temperature manually set by the user. A sun and flame symbol is displayed. To increase the temperature press the Degrees and then increase or decrease by pressing the + or – buttons. When off Moon is displayed. Or if you are going way select the suitcase and the heating will stay off until you return.
Lock the Keypad
To lock the keypad press and hold the bottom left hand corner of the screen for 5 seconds. To unlock repeat.
Reset to Factory Setting
The conduct a master reset to factory settings, press the power button to turn the thermostat off. Press and hold Menu for 5 seconds. Move to menu 17 then hold the down button for 5 seconds.

Dimension

Technical Information

Configuration Menu

To enter into the setting menu please follow the steps below:

  • Step 1: Turn the thermostat off by pressing POWER
  • Step 2: Press MENU you will then see menu 01.
  • Step 3: Use the up and down arrows to adjust the sensor selection which is Menu 01(Air sensing;Air and Floor, or Floor only)
  • Step 4: Press NEXT to move to the next Menu and once you have all the menu options set,
  • Step 5: Press DONE to accept and store.
Menu #

Feature

Explanation

Adjustment

(Press up & down buttons to adjust)

 

01

 

Mode/Sensor Selection

This thermostat is a combination model which allows you to choose 3 different modes.

A mode = Air Sensing Only(Has built-in sensor)

AF mode = Air & Floor sensing (Floor probe must be installed) F mode = Floor Sensing(Floor probe must be installed)

 

A / AF / F

 

02

 

Switching differential

The number of degrees difference before switching.

The default is 1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature.With a 2°C differential the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.

 

1 Deg C, 2 Deg C… 10 Deg C ( 1 Deg C by default)

03 Air Temp Calibration This is to recalibrate the air temp if required -1 Deg C = decrease 1 °C , 1 Deg C = increase 1 Deg C
04 Floor Temp Calibration This is to recalibrate the floor temperature if required -1 Deg C = decrease 1 °C , 1 Deg C = increase 1 Deg C

05

Temperature Readout (AF mode only)

This gives you the option to show the Air Temp, Floor Temp or to show both Air & Floor at intervals

A = Show Air Temperature F = Show Floor Temperature

A-F = Show Floor and Air Temperature in 5 sec intervals

06 Maximum Floor Temp ( AF Mode only) This is to protect the floor surface 20 Deg C – 40 Deg C (40 Deg C by default)
07 Temperature Format This allows the temperature to be set to show Deg Celsius or Deg Fahrenheit Deg C / Deg F
08 Clock Format You can select the clock to show in either 12 or 24 hour time 24 (default), 12- hour or 24-hour clock format
09 Frost Protection This is to avoid your room temp going below 5 DegC On = activated, Off = deactivated

10

5+2 / 7 Day mode

This allows you to programme either 5 days at once, then the 2 days of the weekend separately,

or a full 7 days at the same time or 7 days separately.

01 = 5 + 2 Day Programming

02 = 7 Day Programming

11 Auto/Manual mode selection This allows you to choose Auto / Manual mode 00 = Auto mode 01 = Manual mode
12 Software version This is for review only V1.0
13 Minimum temperature limit This gives you the option to change the minimum set temperature 5 °C~ 20 °C (5 °C by default)
14 Maximum temperature limit This gives you the option to change the maximum set temperature This gives you the option to change the maximum set temperature
15 Sensor type selection This allows you to match your thermostat to different sensor 10 = NTC10K(by default), 100= NTC100K,

3=NTC3K

16 Not at use Reserved for future use
17 Reset This allows you to reset your thermostat to factory default Press and hold down button until you see RES on screen

Contact

AUSTRALIA

NEW ZEALAND

Reference

Download Manual:

Hotwire HWTH Horizontal Programmable THERMOSTAT INSTRUCTION MANUAL

Hotwire HWTH Horizontal Programmable THERMOSTAT INSTRUCTION MANUAL

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago