| LCD symbols |
| Icon Legend |
| AUTO Automatic mode, executes the programmed schedules |
| Er The floor sensor is not being read by the thermostat |
| Setting the clock and day of the week |
| This thermostat is fitted with a real-time clock. It is essential that the clock time and day are set accurately if you require your programmed events to start on time. To set follow the steps below: |
|
|
|
Setting the Programme Schedules
This thermostat has the ability to programme each individual day of the week separately, or programme 7 days of the week at once. You can also programme weekdays (5 days) to one schedule and then weekends (2 days) to a different schedule. See the Menu information for details on how to set this up.(refer to Menu 10) See page 4 of this manual.
This will help you programme your thermostat to come on and off automatically. If you want to simply turn it on and off when required skip this section.
(*). Hint: If you use the default programming of 5 week days plus 2 weekend days you will now need to repeat the above steps for the weekend.
Default Programming is as follows
| Programme | Start Time | Setpoint | Explanation |
| 01 | WAKE 07:00 | 22 °C | This is the time the heating will come on in the morning. |
| 02 | LEAVE 09:30 | 16 °C | This is the time the heating will switch off in the morning. It can also be used to set a minimum temperature for the day. |
| 03 | RETURN 16:30 | 22 °C | This is the time the heating will come on in the afternoon. |
|
04 |
SLEEP 22:30 |
16 °C | This is the time the heating will switch off in the afternoon/evening. If you do not require the heating in the afternoon / evening, simply set this time to a couple of minutes after the “on” time. |
Carefully separate the front half of the thermostat from the back plate by unscrewing the small screw at the bottom of the thermostat. Carefully unplug the ribbon connector which is plugged into the front half of the thermostat. Place the thermostat front half somewhere safe. Terminate the thermostat as shown in the diagrams below.
Screw the thermostat back plate onto the flush box
Warning: This product should be installed by a qualified electrician.
| Manual Mode |
| Press MODE to select Auto/Manual mode. In Manual mode( |
| Lock the Keypad |
| To lock the keypad, press and hold the power button for 5 seconds, you will see a lock symbol |
| Reset to Factory Setting |
| The conduct a master reset to factory settings, press the power button to turn the thermostat off. Press and hold Menu for 5 seconds. Move to menu 17 then hold the down button for 5 seconds. |
To enter into the setting menu please follow the steps below:
| Menu # | Feature | Explanation | Adjustment (Press up & down buttons to adjust) |
|
01 |
Mode/Sensor Selection | This thermostat is a combination model which allows you to choose 3 different modes. A mode = Air Sensing Only(Has built in sensor) AF mode = Air & Floor sensing (Floor probe must be installed) F mode = Floor Sensing(Floor probe must be installed) |
A / AF / F |
|
02 |
Switching differential | The number of degrees difference before switching. The default is 1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature.With a 2°C differential the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature. |
1 Deg C, 2 Deg C… 10 Deg C ( 1 Deg C by default) |
| 03 | Air Temp Calibration | This is to recalibrate the air temp if required | -1 Deg C = decrease 1 °C , 1 Deg C = increase 1 Deg C |
| 04 | Floor Temp Calibration | This is to recalibrate the floor temperature if required | -1 Deg C = decrease 1 °C , 1 Deg C = increase 1 Deg C |
| 05 | Temperature Readout (AF mode only) | This gives you the option to show the Air Temp, Floor Temp or to show both Air & Floor at intervals | A = Show Air Temperature F = Show Floor Temperature A-F = Show Floor and Air Temperature in 5 sec intervals |
| 06 | Maximum Floor Temp ( AF Mode only) | This is to protect the floor surface | 20 Deg C – 40 Deg C (40 Deg C by default) |
| 07 | Temperature Format | This allows the temperature to be set to show Deg Celsius or Deg Fahrenheit | Deg C / Deg F |
| 08 | Clock Format | You can select the clock to show in either 12 or 24 hour time | 24 (default), 12- hour or 24-hour clock format |
| 09 | Frost Protection | This is to avoid your room temp going below 5 DegC | On = activated, Off = deactivated |
| 10 | 5+2 / 7 Day mode | This allows you to programme either 5 days at once, then the 2 days of the weekend separately, or a full 7 days at the same time or 7 days separately. | 01 = 5 + 2 Day Programming 02 = 7 Day Programming |
| 11 | Auto/Manual mode selection | This allows you to choose Auto / Manual mode | 00 = Auto mode 01 = Manual mode |
| 12 | Software version | This is for review only | V1.0 |
| 13 | Minimum temperature limit | This gives you the option to change the minimum set temperature | 5 °C~ 20 °C (5 °C by default) |
| 14 | Maximum temperature limit | This gives you the option to change the maximum set temperature | This gives you the option to change the maximum set temperature |
| 15 | Sensor type selection | This allows you to match your thermostat to different sensor | 10 = NTC10K(by default), 100= NTC100K, 3=NTC3K |
| 16 | Not at use | Reserved for future use | |
| 17 | Reset | This allows you to reset your thermostat to factory default | Press and hold down button until you see RES on screen |
AUSTRALIA
NEW ZEALAND
Download Manual:
Hotwire HWGL1 Programmable THERMOSTAT INSTRUCTION MANUAL
Amex Casino United Kingdom Instead of free spins, you do well and have winnings that…
Best Online Casino For Roulette Time and Again is an HTML5 title, best online casino…
Fastest Payout Online Casinos Bally Wulff is known for their amazing classic slots and Back…
Bison Casino No Deposit Bonus Codes For Free Spins 2026 One reels 1 and 5…
Casinos With Fast Payouts Sky Queen is a medium to high volatility slot offering an…
European Roulette Guide Uk There is a 30x wagering requirement in place on the deposit…