The Y460A2003 Thermostat is for 15 to 30 Vac control of gas- or oil-fueled warm air, steam or hot water heating/electric cooling systems. Your Y460A Thermostat
IMPORTANT
For cooling systems, do not operate cooling if the outdoor temperature is below 50°F (10°C).
IMPORTANT
Turn off power to the system at the main fuse or circuit breaker panel. Most buildings have a separate switch box or circuit breaker for disconnecting power to the furnace.
Carefully unpack your new thermostat.
Remove the cover of the old thermostat. If the cover
does not snap off when pulled firmly from the
bottom, look for screw(s) to loosen to unlock the
cover.
If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of the old thermostat. If you have questions, call the Honeywell Customer Response Center at 1-800-468- 1502.
MOUNT THE SUB BASE
IMPORTANT:
Install your thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at an average temperature. Do not install it where it may be affected by:
USE THE Q539 SUBBASE FOR HEAT AND/OR COOL APPLICATIONS WITH SWITCHING
Tighten the screws after using a spirit level or plumb line to accurately level the sub base. It must be level to maintain accurate calibration.
Wire the Subbase
Y460A for heating/cooling system using separate RCRH terminals. If the old thermostat has a single R terminal, refer to the jumper drawing in the Subbase Wiring procedure.
MOUNT YOUR THERMOSTAT
SET THE TEMPERATURE
Set Subbase Switch
CAUTION
Equipment Damage Hazard. Can cause permanent damage to the compressor. Do not rotate the thermostat dial back and forth just to observe the electrical spark; observe the
compressor’s five-minute minimal-off period.
CAUTION
Equipment Damage Hazard. Can cause permanent damage to the compressor or other equipment. To avoid possible compressor damage, allow the compressor to remain off for five minutes before restarting To avoid possible equipment damage, do not operate the cooling when the outside temperature is below 50°F (10°C). See equipment manufacturer instructions
CAUTION
Equipment Damage Hazard. Can cause permanent damage to the compressor. Do not rotate the thermostat dial back and forth just to observe the electrical spark; observe the compressor’s five-minute minimal-off period.
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of
purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option) within a reasonable period of time. If the product is defective, return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address Honeywell Inc. Return Goods Department 1050 Berkshire Lane Plymouth, MN 55441-4437 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write our Customer Assistance Center, Honeywell Inc., P.O. Box 524, Minneapolis, MN 55440-0524 or call 1-800-468- 1502, Monday-Friday, 7:00 a.m. to 5:30 p.m., Central time. In Canada, write Retail Products ON15-02H, Honeywell Limited/ Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N
Home and Building Control Home and Building Control
Honeywell Inc. Honeywell Limited-Honeywell Limitée
Honeywell Plaza 155 Gordon Baker Road
P.O. Box 524 North York, Ontario
Minneapolis, MN 55408-0524 M2H 3N7
Download Manual:
Honeywell Y460A2003 The Round Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…