This thermostat works on 24 volt systems. It will NOT work on 120/240 volt systems.
This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate
MERCURY NOTICE: Do not place your old thermostat in the trash if it contains mercury in a sealed tube. Contact the Thermostat Recycling Corporation at www. thermostat-recycle.org or 1-800-238-8192 for information on how and where to properly and safely dispose of your old thermostat.
NOTICE: To avoid possible compressor damage, do not run air conditioner if the outside temperature drops below 50°F (10°C).
Conventional Terminal Letters:
Heat Pump Terminal Letters:
You can change options for a number of system functions. Available functions depend on the type of system you have. The functions, designated with four-digit numbers, along with available options are described on pages 3–6
This thermostat is pre-set for a single-stage heating/cooling system.
Setting function 0170 for a heat pump will adjust the default settings.
0112 | Device Name | 52 = Thermostat 1 Basement 18 Fireplace 35 Media Room 52 Thermostat 2 Bathroom 19 Foyer 36 Music Room 53 Upper Level 3 Bathroom 1 20 Game Room 37 Nursery 54 Utility Room 4 Bathroom 2 21 Garage 38 Office 55 Walk In Closet 5 Bathroom 3 22 Great Room 39 Office 1 56 Wine Cellar 6 Bedroom 23 Guest Room 40 Office 2 57 Workshop 7 Bedroom 1 24 Gym 41 Pantry 64 Conference Room 8 Bedroom 2 25 Kid’s Room 42 Play Room 65 Dressing Room 9 Bedroom 3 26 Kitchen 43 Pool Room 66 Meeting Room 10 Bedroom 4 27 Kitchen 1 44 Porch 67 Machine Room 11 Boat House 28 Kitchen 2 45 Rec Room 68 Open Area 1 12 Bonus Room 29 Laundry Room 46 Sewing Room 69 Open Area 2 13 Computer Room 30 Library 47 Spa 70 Server 1 14 Den 31 Living Room 48 Storage Room 71 Server 2 15 Dining Room 32 Lower Level 49 Studio 72 Stock Room 16 Exercise Room 33 Master Bath 50 Sun Room 17 Family Room 34 Master Bed 51 Theater | |
This name will identify the thermostat when you view it remotely. | |||
If you register multiple thermostats, give each one a different name. | |||
0120 | Year Setting (first two digits) | 20 = Year 20xx 21 = Year 21xx | |
0130 | Year Setting (last two digits) | 01–99 (i.e., 2001–2099) | |
0140 | Month Setting | 01–12 (i.e., January–December) | |
0150 | Date Setting | 01–31 | |
0160 | Schedule Options | 4 0 | Program schedule is on (7-day programmable). Program schedule is off. The thermostat can not be programmed. |
0165 Restore Schedule Defaults | 0 1 | Continue using programmed schedule. Restore thermostat program to energy-saving settings | |
0170 Select System | 1 | Heat/cool: Gas, oil or electric heating with central air conditioning. | |
2 3
4
5
6 | Heat pump: Heat pump without backup or auxiliary heat. Heat only without fan: Gas, oil or electric heat without central air conditioning. Heat only with fan: Gas, oil or electric heat without central air conditioning. Heat only (no fan): Gas, oil or hot water heat without central air conditioning. Cool only: Central air conditioning only. | ||
Type | |||
If you are not sure of your heating/cooling system type or have other questions, go to wifithermostat.com | |||
7 | Heat pump: Heat pump with backup or auxiliary heating. | ||
8 | Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 | ||
cooling stages (wires on Y and Y2). | |||
9 | Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 | ||
cooling stage (wire on Y). | |||
10 | Heat/Cool Multiple stages: 1 heat stage (wire on W), 2 cooling stages | ||
(wires on Y and Y2). | |||
11 | Heat pump multiple stages: 2 heat stages (wires on W and W2), | ||
2 cooling stages (wires on Y and Y2) (no aux. heat). | |||
12 | Heat pump multiple stages: 3 heat stages (wires on W, W2, and Aux), 2 cooling stages (wires on Y and Y2) (with aux heat). | ||
0173 Heat Pump Type | 0 | Air to air heat pump | |
1 | Geothermal heat pump | ||
0180 Heating Fan Control | 0
1 | Gas or oil heat: Use this setting if you have a gas or oil heating system (system controls fan operation). Electric heat: Use this setting if you have an electric heating system (thermostat controls fan operation). | |
0190 Heat Pump | 0 | Cooling changeover valve: Use this setting if you connected a wire | |
labeled “O” to the O/B terminal. | |||
Changeover Valve | |||
1 | Heating changeover valve: Use this setting if you connected a wire | ||
(for heat pumps | |||
labeled “B” to the O/B terminal. | |||
only) | |||
0200 Back-up Heat | 0 | Electric | |
1 | Fossil fuel | ||
Source | |||
0210 External Fossil Fuel Kit | 0 1 | No Yes | |
0220 1st stage compres- sor cycle rate | 3 | Recommended for most compressors [Other options: 1, 2, 4, 5 or 6 CPH] | |
0230 2nd stage com– pressor cycle rate | |||
0240 Heating Cycle Rate | 5 9 3
1 | Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency). Electric furnace: Electric heating systems. Hot water or high-efficiency furnace: Hot water system or gas furnace (more than 90% efficiency). Gas/oil steam or gravity system: Steam or gravity heat systems. [Other options: 2,4,6,7,8,10,11,12] | |
0250 Heating Cycle Rate Stage 2 | |||
0260 Heating Cycle Rate Stage 3 | |||
0280 Backlight | 0 | Backlight off, then on for approximately 8 seconds after keypress. | |
1 | Backlight always on low intensity, full bright after keypress. |
0300 Manual/Auto Changeover | 0 1 | Manual changeover (Heat/Cool/Off). Automatic changeover (Heat/Cool/Auto/Off). Automatically turns on Heat or Cool based on room temperature. Note: System maintains minimum 3°F difference between heat and cool settings. | |
0310 Auto changeover deadband | 3 | Heat/cool temperature 3°F apart (1.5°C) [Other options: 2-9 (2°F to 9°F/1°C to 5°C)]) | |
0320 Temperature For- mat (°F/°C) | 0 1 | Fahrenheit Celsius | |
0330 Automatic Daylight Saving Time Ad– justment | 0 1 | Off On | |
0340 Remote Temp Sensor | 0 1 2 3 | None Outdoor for Display Outdoor for Control Remote Indoor | |
0346 Dual Fuel Heat Pump Upstage to Furnace Timer | 0 1 3 5 6 7 8 | Disabled 30 minutes 60 minutes 1.5 hours 2 hours 3 hours 4 hours | 9 5 hours 10 6 hours 11 8 hours 12 10 hours 13 12 hours 14 14 hours 15 16 hours |
0347 Droop Temperature (Steady State) | 2 | °F (1.0 °C) [Other options: displayed in °F or °C] | |
0349 Backup Heat Manual Droop Tem- perature | 0 1 | Comfort (Off) Economy | |
0350 Heat Pump Com- pressor Lockout | 0 | Off [Other options: displayed in °F or °C] | |
0360 Heat Pump Aux Lockout | 0 | None [Other options: displayed in °F or °C] | |
0500 Filter Change Reminder The reminder appears after selected number of days run time not actual time. | 0 1 2 3 4 5 6 7 8 | Off (no reminder) Reminder after 10-day run time (about 1 calendar month) Reminder after 30-day run time (about 3 calendar months) Reminder after 60-day run time (about 6 calendar months) Reminder after 90-day run time (about 9 calendar months) Reminder after 120-day run time (about 1 calendar year) Reminder after 180-day run time (about 18 calendar months) Reminder after 270-day run time (about 2 calendar years) Reminder after 365-day run time (about 3 calendar years) | |
0502 Furnace filter for Run time | 0 1 | Counts both heat and cool Counts cool only | |
0510 Humidifier Pad Replacement Re- minder | 0 1 2 3 | Disabled 30-day run time (about 3 months) 60-day run time (about 6 months) 90-day run time (about 9 months) | |
0520 UV Lamp Replace- ment Reminder | 0 1 2 | Disabled 365 days 730 days |
0530 | Smart Response Technology | 1 0 | On Off |
0580 | Compressor protection | 5 | 5 minute compressor off time [Other options: 0, 1, 2, 3 or 4-minute off time] |
0600 | Heat temperature range stop | 90 | Max. heat temperature setting is 90°F (32°C) [Other options: 40-89°F (4°C to 32°C)] |
0610 | Cool temperature range stop | 50 | Min. cool temperature setting is 50°F (10°C) [Other options: 51-99°F (11°C to 37°C)] |
0640 | Clock Format | 12 24 | 12-hour clock (i.e., “3:30 pm”) 24-hour clock (i.e., “15:30”) |
0650 Extended fan timer (heat) | 0 90 | Off Fan runs for 90 seconds after call for heat ends [Other options: 30, 60, 120] | |
0660 Extended fan timer (cool) | 0 90 | Off Fan runs for 90 seconds after call for cooling ends [Other options: 30, 60, 120] | |
0670 Keypad lock | 0 1 2 | Keypad unlocked (fully functional) Partially locked (access to temperature settings only) Fully locked | |
0680 Heat temperature control | 2 1 3 | Standard temperature control (recommended) Choose if room is warmer than set temperature Choose if room does not reach set temperature | |
0690 Cool temperature control | 2 1 3 | Standard temperature control (recommended) Choose if room is cooler than set temperature Choose if room does not reach set temperature | |
0695 Finish On High Heat Stage | 0 1 | No Yes | |
0696 Finish On High Cool Stage | 0 1 | No Yes | |
0700 Temperature display offset | 0 | Thermostat displays actual room temperature [Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)] | |
0710 | Restore Original Settings | 0 1 | No Disconnects thermostat from Wi-Fi and restores original settings (erases customizations). |
0890 | Wi-Fi On/Off | 1 0 | Wi-Fi is on and can be connected to a Wi-Fi network. Wi-Fi is off. Thermostat cannot be connected to a Wi-Fi network. If you are not connecting the thermostat to a Wi-Fi network this will remove the text “Wi-Fi Setup” from the messaging center. |
0900 | Wi-Fi Connection | 1
0 | Connected to Wi-Fi network. This is set automatically when the thermostat is connected to the Wi-Fi network. Set to 0 to disconnect from the Wi-Fi network. |
CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.
Display is blank
“Wait” appears on the screen
The button on the lower right of the screen is blank
The red light is on
The heating or cooling system does not respond
The heating system is running in cool mode
Automation and Control Systems
Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422
http://customer.honeywell.com
® U.S. Registered Trademark.
Apple, iPhone, iPad, iPod touch, and iTunes are trademarks of Apple Inc.
All other trademarks are the property of their respective owners.
© 2012 Honeywell International Inc.
69-2733EFS—01 M.S. 08-12 Printed in the U.S.A.
Download Manual:
Honeywell TH8320WF Wi-Fi Programmable Thermostat System Setup Guide
Honeywell TH8320WF Wi-Fi Programmable Thermostat System Setup Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…