Package Includes:
Compatibility
Customer Assistance
WEB honeywellhome.com
PHONE 1-800-633-3991
Wiring UWP
Push down on the tabs to put the wires into the inner holes of their corresponding terminals on the UWP (one wire per terminal) until they are firmly in place. Gently tug on the wires to verify they are secure. If you need to release the wires again, push down the terminal tabs on the sides of the UWP.
Conventional Systems | Heat pump systems | ||
Terminal | Description | Terminal | Description |
S/S | Input for a wired indoor, outdoor sensor | S/S | Input for a wired indoor, outdoor sensor |
Y | Compressor Stage 1 | Y | Compressor Stage 1 |
Y2 | Compressor Stage 2 | Y2 | Compressor Stage 2 |
G | Fan Relay | G | Fan Relay |
C | 24VAC Common wire from secondary side of cooling transformer (if 2 transformers) | C | 24VAC Common wire from secondary side of cooling transformer |
K* | Connect to K on C-wire adaptor | K* | Connect to K on C-wire adaptor |
U/U** | Relay for humidifier, dehumidifier, or ventilator | U/U** | Relay for humidifier, dehumidifier, or ventilator |
A | L/A | Connect to compressor monitor | |
W | Heat Stage 1 | O/B | Changeover valve for heat pumps |
W2 | Heat Stage 2 | Aux | Backup Heat |
E | Emergency Heat | ||
R | 24 VAC Heating transformer | R | 24 VAC Heating transformer |
Rc | 24 VAC Cooling transformer | Rc | 24 VAC Cooling transformer |
Set R Slider Tab, see Figure 9.
Set U Slider Tab, see Figure 10
Whole house humidifier, dehumidifier, or ventilator
Using U Slider Tab
NOTES:
This thermostat requires a C-Wire. If a C-Wire is not available, use C-Wire adapter accessory THP9045A1098.
Heat pumps systems
THP9045A1098. If you do not have separate wires for the Aux and E terminals, connect the wire to the Aux terminal.
The display will walk you through equipment setup, connecting to wireless sensors, and connecting to Wi-Fi. The final step in the setup is a place you can enter your company name and contact information as well as your Contractor PRO™ number. That contact information will be displayed with alerts or reminder messages to keep you connected to your customer.
Enter your company’s Contractor PRO™ account number to participate in periodic promotions. Earn incentives such as bonus points for every T10 Pro Smart thermostat you install during eligible promotional periods. Your account number is an 8-digit number that includes a leading zero (example 01234567). For questions on this bonus or membership to the Contractor PRO™ loyalty program, contact us at 1-800-919-4835 or contractorpro@resideo.com.
How to use your thermostat
The screen will wake up by pressing the center area of the displayed temperature.
How to use Priority
Priority creates an average temperature in your home based on specific rooms. This allows you to prioritize comfort where you want it.
Installer Setup
Installer Test
Devices & Sensors
Thermostat Information
Dealer Information
Finding date code (passcode) for installer setup. Open the Menu icon, and choose Thermostat Information. Write down the date code.
Alerts and notifications
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.
CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.
Temperature Ranges
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)
Operating Ambient Temperature
32 °F to 120 °F (0 °C to 48.9 °C)
Shipping Temperature
-20 °F to 120 °F (-28.9 °C to 48.9 °C)
Operating Relative Humidity
5% to 90% (non-condensing)
Electrical Ratings
Terminal | Voltage (50/60Hz) | Running Current |
W Heating | 20-30 Vac | 0.02-1.0 A |
(Powerpile) | 750 mV DC | 100 mA DC |
W2 (Aux) Heating | 20-30 Vac | 0.02-1.0 A |
E Emergency Heat | 20-30 Vac | 0.02-0.5 A |
Y Compressor Stage 1 | 20-30 Vac | 0.02-1.0 A |
Y2 Compressor Stage 2 | 20-30 Vac | 0.02-1.0 A |
G Fan | 20-30 Vac | 0.02-0.5 A |
O/B Changeover | 20-30 Vac | 0.02-0.5 A |
L/A Input | 20-30 Vac | 0.02-0.5 A |
U | 20-30 Vac | 0.02-0.5 A |
Power Consumption
3 VA
Physical Dimensions in inches (mm) (H x W x D)
T10 PRO Wi-Fi Thermostat:
4.9″ x 3.7″ x 0.93″ (125.4 x 94.1 x 23.68)
UWP Mounting System (included):
2-9/32″ x 2-13/64″ x 2-43/64″ (58 x 56 x 10)
Standard Installation Adapter (included):
3-29/32″ x 3-57/64″ x 21/32″ (99 x 99 x 17)
Cover Plate – Medium (included):
5-11/64″ x 5-1/2″ x 11/16″ (131.4 x 139.7 x 17.5)
Cover Plate – Large (THP2400A1068):
6-7/64″ x 6-7/64″ x 9/32″ (155 x 155 x 7)
For Warranty, information go to http://honeywellhome.com
FCC REGULATIONS
§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
IC REGULATIONS
RSS-GEN
This device complies with Industry Canada’s license-exempt RSSs.
Operation is subject to the following two conditions:
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.
©2019 Resideo Technologies, Inc. This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-633-3991
The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.
33-00423EFS—03 M.S. Rev. 03-19
Printed in the U.S.A.
Download Manual:
Honeywell T10 Pro THX321WFS2001W Programmable Thermostat Installation Guide
Other Manuals:
Honeywell Home T10 and T10+ Pro THX321WF2003W Smart thermostat Manual
Honeywell T10 Pro THX321WFS2001W Programmable Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…