The Rondostat packaging contains:
Setting date and time
After the batteries have been inserted or replaced, the Rondostat automatically requires the date and time to be entered.
Correcting the date and time
Rondostat changes over automatically from Summer to standard time. If however, you want to correct the date and time during operation:
Rondostat can be mounted easily on all common radiator valves without causing any dirt or water staining. You no longer require the old thermostat head:
Selecting the adapter
Mounting the valve baseplate
Attaching the operating unit
What is a thermostatic radiator valve (TRV)
TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler. They should be set at a level that gives you the room temperature you want. These settings may have to be different in each room, and you should set the TRVs to suit each room and then leave them to do their job. Turning a TRV to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the boiler size and setting, and the radiator size. Turning the TRV to a lower setting will result in the room being controlled at a lower temperature, and saves energy. TRVs need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. TRVs cannot turn off the boiler when the house is warm. To do that, you will need a room thermostat as well. The radiator in the room with the room thermostat should not normally have a TRV, but, if it does, keep the TRV on the maximum setting and adjust the room thermostat as explained with the instructions
Temperatures and control periods
Rondostat differentiates between two temperatures:
In automatic mode Rondostat changes between these two temperatures in accordance with an adjustable time program:
Time program
The heating and economy periods (the 2nd heating period is optional) are specified by freely programmable time programs. The factory default setting for the time program is:
Adjustment dial
Use the adjustment dial to change the current room temperature to the next switching point in automatic mode.
Setting the comfort and economy temperatures
Operating the Rondostat comfortably
In order to adjust the time program comfortably turn the retaining bracket upwards and remove the operating unit (display E2). Slide the operating unit back on afterward. Turn the retaining bracket to the rear (display E2 disappears).
Lost your way in the program?
Press the AUTO button. Rondostat reiects the last entry and returns to Auto or Manu mode.
Time program: Heating and economy periods
Rondostat disposes of 2 independent time programs Select the week or day programs.
Setting the week programs (all days identical):
Deleting switching points
Window function
If you open a window so that the temperature drops quickly, the Rondostat closes the radiator valve in order to save energy. The message OPEn is displayed. When the temperature rises again – or 30 minutes have passed – Rondostat opens the valve again. You can also open the valve beforehand by pressing the PROG button or turning the adjustment dial.
Note: This functionality is only effective when the Rondostat is located directly within the flow of cool air from an open window.
Valve protection
If the valve has not been opened once completely within the period of a week, Rondostat automatically opens the valve briefly on Mondays in order to prevent seizing (display CYCL.).
Frost protection
If the temperature drops below 4°C, the Rondostat opens the radiator valve until the temperature rises above 6°C again. In this way Rondostat prevents the radiator from freezing.
Heating break
Child-proofing
Rondostat operates with a factory setting with the optimum valve lift (default lift) that is required for room temperature control.
Full-stroke mode
If the entire valve stroke is to be used or if the valve does not close completely, change to the full-stroke mode.
Default-stroke mode
Press and hold the Prog button and slide the operating unit onto the valve baseplate and lock it (display dEF).
Closing the radiator valve
Empty batteries
If bAtt is displayed permanently, the radiator valve is opened.
Emergency operation when batteries are flat
Restoring the factory settings
WEEE directive 2002/96/EC – Waste Electrical and Electronic Equipment directive
Dispose of the packaging and product in a corresponding recycling center. Do not dispose of the unit with domestic refuse. Do not burn the product.
DOWNLOAD MANUALS:
HONEYWELL HR20 Programmable Radiator Thermostat Operating Manual
HONEYWELL HR20 Programmable Radiator Thermostat Operating Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…