The TruelAQ® monitors and automatically adjusts operation of your whole-house humidifier, dehumidifier, ventilator, or bath fan. Maintaining proper indoor humidity minimizes the potential for unhealthy airborne pollutants to grow. Having too little humidity can leave you vulnerable to infections and uncomfortable dry skin. Too much humidity creates ideal breeding grounds for mold, mildew and dust mites. Humidified air also feels warmer in the winter, and dry air feels cooler in the summer. TruelAQ can adjust humidity with or without dependency on HVAC equipment operation. If you have both a humidifier and dehumidifier installed, the TruelAQ can automatically change over to the appropriate equipment based on your comfort settings and the changing outdoor conditions. TruelAQ can also deliver fresh air with or without dependency on HVAC equipment operation. Today’s building codes require homes to be built more tightly for energy efficiency, but that tightness can also trap indoor air pollutants, such as cooking odors, cleaning agents, radon, and carbon dioxide/monoxide. TruelAQ provides cost-effective ventilation in accordance to industry standards. In addition, the TruelAQ can be programmed to deliver ventilation during set times of the day or night
TruelAQ® can be used to control the humidity levels in your home, and control fresh air intake in accordance to industry recommendations (ASH RAE 62.2).
Display screen reference
Set humidifier by pressing UP/DOWN arrows.
Changing humidifier settings
Press “More” to enter Window Frost Protection. Use the UP/DOWN arrows to set frost protection level.
On the first cold day after TruelAQ® is installed, look for condensation on windows. If present, lower Frost Protection by one. Once set for your home, Frost Protection does not need to be changed again.
Changing dehumidifier and ventilation settings
Note: These items will appear only if a ventilator is installed.
Changing time of day and service timers
Service Timers
Service timers appear when the humidifier, dehumidifier, ventilator, air filter, and/or UV bulbs need service. Your HVAC technician will set these timers during installation.
Resetting Service Timers
Press and hold the DOWN arrow for 5 seconds to reset your service timers.
Pin | Pin description | Pin capacity |
R | 24V supply. Must be common to G output. | 24Vac±20% 1 .5 amp max. |
C | 24V suooly common. | 24Vac±20% |
Sensor | Communication and supply bus to remote sensors (sensor pins not polarized). | 24Vdc 64mA max out |
Sensor | ||
Switch | Override switch input. Active when R is applied | 24Vac±20°/o, 10mA max in |
w | W input to sense when the thermostat is calling for heat. Active when R is applied. | 2:4Vac±20%, 10mA max in |
G | G input to sense fan calls. Active when R is applied. Fan output to activate system fan. R8222 lsollation Relay may be required if G is not isolated through the thermostat. | 24Vac±20%, 10mA max in 24V:ac fmm IR, 1Amo max out |
Vent 1 | Dry contact output. Opens the vent damper of an HRV or the bathroom fan and Damper. | 24Vac from R, 1Amp max out |
Vent 2 | ||
Dehum1 | Dry contact output. Starts the Dehumidifier or an alternate fan speed. | 24V:ac from R, 1Amp max out |
Dehum 2 | ||
Hum 1 | Dry contact output. Starts the Humidifier. | 24Vac from R, 1Amp max out |
Hum 2 |
Mounting the outdoor sensor
Advanced HVAC installer setup instructions
Hum Service Timer | 0,1,3,6,12 (months intermittent | |||
Hum Water Filter Service | 0.1,3,6,12 | (months intermittent1
(months continuous | ||
Air Filter Service Timer | 0,1.3,6.12 | |||
Vent Filter Service Timer | 0,1,3,6,1.2 | |||
Vent Service Type | 0=Clean ventilation filter 1=Chanae ventilation filter | |||
110 | UV Bulb Service Reminder | I 0,6,12,24 (months continuous | ||
115 | Vent Options I | 0=No vent in.stalled 1=Ventilation usi.ng VENT contacts 2=Ventilation using VENT contacts for high speed and DEHUM contacts for low speed (only if dehum not installed) 3=Ventilation using VENT contacts and DEHUM contacts activated together (auxiliary ventilation device such as exhaust fan | ||
120 | Vent Operation I | 0=Vent forces HVAC fan on 1=Vent operates independent of HVAC fan | ||
125 | Proarammed Vent | I 0=OFF: 1=ON | ||
130 | Program Start Time 115 min increments | |||
appears onlv if ISU125=1) 5:00 PM | ||||
135 | Program End Time 115 min increments appears onlv if ISU125=1) 9:00 AM | |||
140 | ASHRAE: # of Bedrooms 11-6 bedrooms: 2 | |||
145 | ASHRAE: Home’s So Ft 110=1.000 Sa Ft: UP to 50=5i000 SQ Ft |
3:30 CFM: 4=40 CFM1 u | |||||
Maximum Vent | 00: 30%-95%. (0 | ,o setting runs to ASHRAE 100% | |||
Vent Shut-offs | O=Auto vent regardless of outdoor conditions 1=Off at 75°F dew point or :99°F air temp 2=Low speed at 65°F dew point or 85°F air temp. Off at 75°F dew point or 99°F air temp Note: If optiion 1 or 2 is selected, then ASHRAE 62.2 Standard will not be met. | ||||
165 | Dehumidification Via Fresh Air Ventilator | 0=Do not use ventilation for dehum 1=Allow vent for dehum per outdoor condiU01ns. With dehum installed, control. to setpoint. Without dehum installed, control to the Hum setpoint +10% max. 60%). |
TruelAQe Control and Outdoor Sensor
Power Supply
In the Event of Power Failure
Mechanical Design
5-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective, (Q return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or (ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE FIVE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/ Honeywell Limitee, 35 Dynamic Drive, Toronto, Ontario M1V429.
Automation and Control Solutions
Download Manual:
Honeywell DG115EZIAQ TrueIAQ Digital THERMOSTAT Owners Manual
Honeywell DG115EZIAQ TrueIAQ Digital THERMOSTAT Owners Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…