The CM61RF Chronotherm is designed to provide automatic time and temperature control of heating or cooling systems in villas and apartments. It can be used as a part of system in conjunction with gas and oil boilers, circulation pumps, variety of valves and actuators or electric heating systems (<10A). The radio frequency-controlled CM61RF system consists of a room unit T6661C and relay box R6660C (HC60). No wiring to the room unit is required. Installer needs to wire only the relay box to a controlled device (e.g. boiler) and mount the room unit in a suitable location where the RF communication is reliable. The CM61RF display, buttons, and slider layout are identical to CM61 ‘wired’ chronotherm The unit is ideal for consumers who want reliable precise temperature control from a simple to program easy to use product.
DISPLAY LAYOUT
T6661C Room unit
R6660C Relay box
INSTALLER SET-UP
Specific Applications | Setting | Description | ||||
Cycle/ Hour | Minimum ON time (in minutes) | |||||
Heating | Gas Boilers (<30kW) | 6 | 1 | Number of cycles per hour and minimum ON time are the key parameters which allow the adjustment of the control algorithm to meet specific application requirements. Cycles/Hour – Parameter n.9; settings range: 3, 6*, 9,12 cph Minimum ON time – Parameter n.2, setting range:1*,2,3,4,5 min | ||
Oil Boiler | 3 | 4 | ||||
Thermal Actuator | 12 | 1 | ||||
Zone valve | 6 | 1 | ||||
Electric heating | 12 | 1 | ||||
Air conditionin g | Heat Pump/ Air conditioner | 3 | 4 | CM61RF is designed to perform heating or cooling operation. To switch from heating to cooling set parameter n.6 in the installer set-up mode to 0. If you switch between heating and cooling the | ||
Special Features | Description | Setting | ||||
Adaptive Intelligent Recovery TM | The CM61RF will adjust the start time at upward setpoint changes so the desired temperature is reached at the programmed time e.g. 7:00 temperature 21oC.The chronotherm will monitor the start-up period and use this information to modify the start time calculation for the next upward setpoint change. The system will restrict the start time to a max of 3 hours before the programmed comfort time AIR does not function in cooling mode. | 0* – disabled 1 – enabled | ||||
AM-PM/ 24hr Display | Change display format (default 24hr) | 0* – 24 hr display 1 – AM/PM display | ||||
Pump exercise | When enabled the Pump Exercise will switch the relay on for 1 minute at 12:00 a.m. if the relay has not been switched on since 12:00 the previous day. | 0* – disabled 1 – enabled | ||||
Upper Temperature Limit | The normal upper temperature limit of 30 oC can be reduced to 21 oC to save energy. Useful for small commercial premises. | 21-30oC Factory setting 30oC* | ||||
Lower Temperature Limit | The normal lower temperature limit of 5 oC can be increased up to 16 oC to protect the inhabitants from cold. Useful for nursing homes. | 5-16oC Factory setting 5oC* | ||||
Temperature Offset | If the Chronotherm is located in a hot/cold location and cannot be moved then the measured/ displayed temperature can be adjusted by +/- 3 oC. | -3 – +3oC Factory setting 0oC* | ||||
Proportional Band Width (PB) | The PB can be adjusted up to 3 oC (default is 1.5 oC) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems b. Air systems with fast response | 1.5-3.0 K (adjustment step 0.1 K) Factory setting1.5 K* | ||||
Fail-safe mode | The CM61RF allows you to set the fail-safe mode of operation of the heating system when radio communication is lost. By default HC60 output relay will be switched OFF in case of communication loss. Alternatively you may choose to cycle the boiler at 2 min ON and 8min OFF. Useful when the building is not occupied for long periods of time and there is a high risk of frost damage. | 0* – relay OFF 1 – relay cycles | ||||
Accessory | Description | Setting | ||||
Automatic Time Setting (ATS) Module | The ATS module picks up a time signal daily from a European transmitter, so you never need to set or adjust the time. | 0 – no accessory 1 – ATS module |
This feature allows you to adjust CM61RF system to match the specific requirements of the application. Installer Set-up allows
The CM67RF is a radio frequency device and for the best performance should be installed in an open space. Leave at least 30cm distance from any metal objects including wall boxes and at least 1 metre from any other electrical equipment e.g. radio, TV, PC etc. It is recommended that the R6660C relay box is installed before commencing with the room unit installation (refer to appropriate Installation Guide).
ORDERING SPECIFICATION.
Description | Model | Logo | Literature | Spec Sheet |
Radio Frequency Chronotherm (1 day) System Pack | Y6661C1001 | Honeywell | English | ENOR8508 |
RF Chronotherm room unit (1 day) | T6661C1006 | Honeywell | English | ENOR8508 |
RF Chronotherm relay box (HC60) | R6660C1001 | Honeywell | English | ENOR8508 |
Automatic Time Setting Module Europe | Q6667B1007 | – | Multi- Language | ENOR8501 |
Honeywell
Download Manual:
HONEYWELL CM61RF Programmable Thermostat Product Specification Guide
HONEYWELL CM61RF Programmable Thermostat Product Specification Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…