Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model CT2095
Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically control the temperature in your home, keeping you comfortable while saving energy when programmed according to the instructions in this manual. Direct any questions concerning the application of this thermostat to Honeywell Consumer Services at 1-800-468-1502, Monday-Friday, 7:00 a.m.-5:30 p.m., Central time.
MERCURY NOTICE
If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the trash. Dispose of it properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of your old thermostat. If you have questions, call Honeywell Customer Response Center at 1-800-
468-1502. Typical location of a mercury switch in a thermostat.
Step 1. Prepare for Installation
Table 1. Compatibility Information
System Type | Compatible with CT2095 |
Gas—Standing Pilot | Yes |
Gas—Electronic Ignition | Yes |
Gas-Fired Boilers | Yesa,b |
Gas—Millivolt | No |
Oil-Fired Boilers | Yesa,b |
Oil-Fired Furnace | Yes |
Electric Furnace | Yes |
Electric Air Conditioning | Yes |
Baseboard Electric (120/240 Line Volt) | No |
Heat Pumps/Multistage Equipment | No |
Not compatible with any 120/240-volt circuit.
Step 2. Remove Old Thermostat
Replacing a Clock Thermostat that has C or C1 Clock Terminals?
If you are replacing a Honeywell Chronotherm® Thermostat, you may find one or two wires that go to the C or C1 clock terminals on the Chronotherm® Thermostat wiring wallplate. Do not allow them to touch, or you can damage your transformer. Disconnect the wires and wrap them separately, using electrical tape. Do not wrap them together. Place the wires where they do not interfere with the operation of the new thermostat. Record the colors and terminal designation labels of the remaining wires.
Six or more wires?
If there are six or more wires (excluding clock wires attached to terminals), you probably have a variation of a heat pump or multistage system. This thermostat is not compatible with those systems so return the product to the retailer. If you want information about the programmable thermostats that work with your system, call Honeywell Consumer Services at 1-800-468-1502.
Three thermostat wires?
If you have three wires for heating only and can operate the fan using the fan On switch, this thermostat works with your system. However, some hot water (zoned) heating systems have three thermostat wires. The thermostat does not work without installing an isolating relay on these systems. For details, call Honeywell Consumer Services at 1-800-468-1502.
Step 3. Install Batteries
IMPORTANT
Batteries must be installed for the pro-gramming and operation of the ther-mostat and heating/cooling system.
As the batteries run low, a bAt Lo indicator flashes for one to two months before the batteries run out completely. Replace the batteries as soon as possible after the indicator starts flashing. If you do not replace the batteries sometime during the flashing bAt Lo, the indicator eventually stops flashing. bAt Lo then stays on without flashing, indicating the thermostat and heating/cooling system have stopped working and the batteries are almost completely dead.After the batteries are completely dead, the bAtLo indication disappears, leaving a completely blank display.
Press down on the left ends of batteries to remove them. If you insert the new batteries within 20 to 30 seconds of removing the old ones, you do not need to reprogram the thermostat. However, if the display is blank, the batteries are dead or incorrectly installed and you must reprogram. See Step 4.
IMPORTANT
Although the thermostat has a low bat-tery indicator, replace the batteries once a year to prevent the thermostat and heating/cooling system from shut-ting down due to lack of battery power. As a precaution, when leaving home for longer than a month, change bat-teries before you leave to prevent the system from shutting down due to lack of battery power.
Step 4. Program Thermostat
After the batteries are installed, the thermostat can be easily programmed in your hand before it is installed on the wall. If you prefer to program the thermostat after it is installed on the wall, go to Step 7 and return later to this programming section. The Personal Programming Chart, Tables 2 and 3, may be helpful for planning your program schedule of time and temperature settings for various times of the day. Four time periods are available during weekdays — WAKE, LEAVE, RETURN, and SLEEP; view these periods individually on the display as you press the Weekday key.
Table 2. Personal Programming Chart for Heating
Days of Week | Heating Program Start Time | Heating Temperaturea |
Weekdays | ||
WAKE | ||
LEAVE | ||
RETURN | ||
SLEEP | ||
Weekendsb | ||
WAKE | ||
SLEEP |
Table 3. Personal Programming Chart for Cooling
Days of Week | Cooling Program Start Time | Cooling Temperaturea |
Weekdays | ||
WAKE | ||
LEAVE | ||
RETURN | ||
SLEEP | ||
Weekendsb | ||
WAKE | ||
SLEEP |
NOTE: Batteries are required for operation and programming. When inserting batteries, set the System switch to Off. Remove the battery door (on the thermostat left side) using a coin at the bottom. Follow instructions in Step 3. Also see the label inside the battery cover for abbreviated programming procedures for your thermostat.
To set time, press and release
Heating Program
With System switch at Heat, press and release
With System switch at Cool, follow the same instructions as for the Heating Program. After programming, adjust the Fan and System switches, as desired. Press and release
Operating Your Thermostat
System switch must be set to Heat or Cool to perform the following:
Temporarily Change Temperature for current period only — Press ;
Hold a Temperature Indefinitely (such as when on vacation) — Press and; HOLD
Check Current Temperature Setting — Press .
Check Programs — Press
Cancel Program — Press
Check Usage — Press
Permanently Change a Program — Repeat Heating Program or Cooling Program steps, as applicable.
Return to Normal Program or Start Program — Press
The thermostat fan operation switch, labeled FUEL SWITCH (see illustration) is factory-set in the F position. This is the correct setting for most systems. If your system is an electric
heat system, set the switch to E to allow the fan to turn on immediately with the heating in a system when the G terminal is connected.
Step 6. Adjust System On-Time, °F/°C, As Required
The thermostat on-time is factory-set for a warm air, gas or oil heating system. If you are installing it on another type of system, adjust the on-time accordingly by setting screws A and B on the back of the thermostat. Use the heating system table shown in the illustration as a guide. The system on-time should be optimized according to the type of system to maximize comfort. Setting the screw “out one turn” means turning the screw approximately 360° counterclockwise, or about one complete turn.
In the unlikely event that you want a longer furnace on-time, readjust screws A and/or B as follows:
First, turn both screws in completely, then adjust for system type:
NOTE: This thermostat does not have a setting for steam/gravity air; cycles would not be long enough for accurate temperature control.
IMPORTANT
When using a high efficiency furnace such as a 90 percent or greater Average Fuel Utilization Efficiency (AFUE) unit, adjust screw A out one turn and leave screw B in.
Step 7. Mount Thermostat Mounting Plate
Step 8. Wire Thermostat Terminals
NOTE: All wiring must comply with local codes and ordinances. If unsure about householdwiring procedures, call your localheating/air conditioning contractor.
2-WIRE HEAT-ONLY (JUMPER INTACT) 2-WIRE HEAT-ONLY (JUMPER INTACT)
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
5-WIRE HEAT/COOL (JUMPER REMOVED) 3-WIRE COOL-ONLY (JUMPER INTACT)
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
Step 9. Mount Thermostat
NOTE: To remove thermostat from wall, first pull out at bottom of thermostat, then remove top.
Step 10. Check Thermostat Operation After Programming and Installing
Heating
Do not check heating system operation by jumpering thermostat terminals such as gas valve, zone valve, and oil burner control at the primary control. This damages the thermostat. Instead, jumper R and W wires at the thermostat Move the System switch to Heat and the Fan switch to Auto.
TEMP Press TEMP key until the set- ting is about 10°F (6°C) above room temperature. Heating should start and the fan should run after a short delay (immedi- ately if fan operation switch is set to E position). Press TEMP key until setting is about 10°F (6°C) below room temperature. The heating equip-ment should shut off.
Cooling
To avoid possible compressor damage, do not operate the cooling system when outdoor temperature is below 50°F (10°C). See compressor manufacturer instructions.
IMPORTANT
When cooling setting is changed, ther-mostat delays up to five minutes before turning on the air conditioner. This delay protects the compressor.Move the System switch to Cool and the Fan switch to Auto. Press TEMP key until setting is about 10°F (6°C) below room temperature. The cooling equipment and fan should start.
Press TEMP key until the setting is about 10°F (6°C) above room temperature. The cooling equipment and fan should stop. Move the System switch to Off; keep the Fan switch at Auto. The system and fan should be off.
Step 11. Set Fan and System Switches
First set the Fan switch.
Fan Auto: Normal setting for most Auto On homes. A single-speed fan will turn on automatically with the air conditioner or furnace. A two-speed fan usually runs on high with the air conditioner and on low with the furnace.
Fan On: The fan runs continuously. Auto On Use for improved air circulation during special occasions or for more efficient electronic air cleaning. (In a heat-only system, fan runs continuously only if fan relay is connected to the thermostat.)
Then set the System switch. Cool: The thermostat controls your air conditioning system.
Off: Both the heating and air conditioning systems are off.Heat: The thermostat controls your heating system.
If… | Then… |
Display does not come on. | Set the System switch to Off. Remove batteries. Insert them backward for at least five seconds to reset the thermostat. Replace batteries correctly. Display should come on. |
Make sure batteries are fresh and installed correctly. | |
Temperature display does not go lower than 45°F (7°C) or higher than 88°F (31°C) during programming. | You have reached the temperature setting limit. The setting range is 45°F to 88°F (7° to 31°C). |
Temperature change occurs at wrong times. | Check the program times for the questionable period. Be sure that AM and PM indications are correct. Make sure the current day and time are correct. Reprogram, if necessary. |
If… | Then… |
Heating does not come on. | Check that the System switch is set to Heat. |
Make sure the heating setpoint is above the room temperature. | |
Check the system fuse or circuit breaker and replace or reset, if necessary. | |
Make sure the System switch is in the On position; set it to On if it is in the Off position. | |
If temperature setting is higher than the current temperature and the display says HEAT, contact Honeywell Consumer Services at 1-800- 468-1502. | |
Cooling does not come on. | Check that the System switch is set to Cool. |
Make sure the cooling setpoint is below the room temperature. | |
Check the system fuse or circuit breaker and replace or reset, if necessary. | |
Make sure the System switch at the air conditioner is in the On position; set it to On if it is in the Off position. |
If… | Then… |
Cooling does not come on (Continued). | The thermostat has a built-in time delay on cooling. Allow five to ten minutes after changing the setting before the air conditioner starts. |
If temperature setting is lower than current temperature, and the display says COOL, move the System switch from Cool to Off for ten minutes. After ten minutes, return the switch to the Cool position. If air conditioner comes on, compressor may have reached its high-limit temperature protection and shut down.If air conditioner does not come on after the ten minutes and the display says COOL, contact Honeywell Consumer Services at 1-800-468-1502. | |
If two- or four-wire installation, verify R-Rc jumper is installed. | |
The house is too warm or too cool. | Press Present Set key to check the current temperature setting. |
If desired, change the temperature setting. See Cooling Program section. | |
SYSTEM ON indicator is lighted, but no heat is coming from the registers. | Allow time for the furnace to heat up and the fan to come on before checking for heat at the register. (Check to make sure system on-time is set correctly. See Step 6.) |
For all questions concerning this thermostat, please read and follow the instructions. If additional assistance is needed, call Honeywell Consumer Services at 1-800-468-1502, Monday – Friday, 7:00 a.m. – 5:30 p.m. Central time. Before you call, please have the following information available—thermostat model number and date code, type of heating/cooling system (hot water, warm air, oil, gas, etc.), and number of wires connected to the thermostat.
NOTICE
This equipment is a Class B digital apparatus, which complies with Canadian Radio Interference Regulations, CRC c.1374.
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option) within a reasonable period of time.
If the product is defective,
Honeywell Inc.Canada: Honeywell Limited/Honeywell Limitée Return Goods Department Product ServicesON15-FFE
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write our Customer Assistance Center, Honeywell Inc., P.O. Box 524, Minneapolis, MN 55440-0524 or call 1-800-468-1502, Monday-Friday, 7:00 a.m. to 5:30 p.m., Central time. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 2C9.
TYPICAL ENERGY SAVINGS FOR REPRESENTATIVE CITIES IN THE U.S. AND CANADA
Home and Building Control Home and Building Control
Download Manual:
Honeywell Home CT2095 Programmable Thermostat INSTALLATION INSTRUCTIONS
Honeywell Home CT2095 Programmable Thermostat INSTALLATION INSTRUCTIONS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…