This thermostat is designed to control an electric heating system such as a baseboard heater, a convector or a fan-forced heater.
The thermostat CANNOT be used with:
SUPPLIED PARTS
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.
Connect the thermostat wires to the heating system (load) and to the power supply.
2-wire Installation/4-wire Installation
Configuration switches are on the back of the faceplate. Factory settings are inside gray cells.
# | Parameter | Right | Left |
1 | Settings lock 1 | Lock | Unlock |
2 | Fan-forced heater 2 | Fan Yes | No |
3 | Unit | °F | ºC |
The thermostat generally displays the room temperature.
Parameter | Options | Display and the default setting |
Minimum setpoint | 5°C – 30°C (41°F – 86°F) NOTE: The minimum setpoint cannot be set higher than the value set for the maximum setpoint. | |
Maximum setpoint | 5°C – 30°C (41°F – 86°F) NOTE: The maximum setpoint cannot be set lower than the value set for the minimum setpoint. |
PROBLEM | SOLUTIONS |
The thermostat is hot. | This is normal unless the thermostat is too hot to touch. Ensure that the heater capacity does not exceed the thermostat’s maximum load. |
The wrong temperature is displayed. | Avoid any of the following conditions:
|
The display disappears and reappears after a few minutes. | The thermal circuit breaker on the heater has temporarily opened. This can happen if the heater is obstructed by furniture or curtain and has overheated, or if the thermal circuit breaker is defective or too sensitive. |
The display looks faded when the heating is activated. | The heater capacity is probably less than the thermostat minimum load requirement. The thermostat cannot be used below that rating. |
LO is displayed. | The measured temperature is below the display range. The heating is activated. |
HI is displayed. | The measured temperature is above the display range. The heating is deactivated. |
El, E2 is displayed. | Verify the thermostat and sensor connections. The heating is deactivated. |
Supply | 240 VAC, 60 Hz |
Minimum load | 2 A (resistive only) 500 W @ 240 VAC |
Maximum load | 12.5 A (resistive only) 3000 W @ 240 VAC |
Display range | 0°C to 50.0°C (32°F to 122°F) |
Setpoint range | 5.0°C to 30.0°C (41°F to 86°F) |
Resolution | 0.5°C (1°F) |
Operating temperature | 0°C to 50.0°C (32°F to 122°F) |
Storage temperature | -20.0°C to 50.0°C (-4°F to 122°F) |
Permanent memory | You do not need to adjust the temperature or thermostat configurations following a power outage. |
ICES-003 Class B Notice – Avis NMB-3, Classe B | This Class B digital apparatus complies with Canadian ICES-003. |
Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of three (3) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).
If the product is defective,
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage that occurred while the product was in the possession of a consumer.
Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY THAT RESIDE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-831-2823.
If you have any questions about the product installation or use, contact us at 1-800-831-2823
CAUTION: ELECTRONIC WASTE NOTICE
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health.
FCC statement available: https://customer.resideo.com/en US/support/residential/ codes-and standards/FCC15105/Pages/default.aspx
Download Manual:Aube TH109PLUS Non-programmable Thermostat Owner’s Manual
Honeywell Aube TH10pPLUS Non-programmable Thermostat Owner Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…