Hexa CONTROL

Hexa CONTROL XH-W3002 TEMPERATURE CONTROL THERMOSTAT Data Sheet

Hexa CONTROL XH-W3002 TEMPERATURE CONTROL THERMOSTAT

SPECIFICATION

Housing Meterial Plastic (IP22)
Temperature Range -50 … 110 °C
Working Mode Heating and Cooling
Temperature Accuracy 0.2 °C
Measuring Accuracy 0.1 °C
Input Measurement NTC 10K, 1 meter waterproof probe
Input Power Suply 12V DC / 24V DC / 230V AC
Output Power 120W, Direct 2 point On/Off output
Output Current Max. 10A
Size 60X45X31mm
Mounting DIN-Rail / Wall Surface
Models Power Supply
XH-W3002-12 12 VDC
XH-W3002-24 24 VDC
XH-W3002-230 230 VAC

SETTING

  • When connect to power supply, press the UP and DOWN buttons at the same time more than 3 seconds, display show 888
  • If display LLL. means the sensor is fault, need to check the sensor.
  • If displat HHH, means the temperature is above the range
  • Display always shows the real-time temperature
  • Start temperature < Termination temperature will be Heating mode
  • Start temperature > Termination temperature will be Cooling mode

P0: Set Start temperature
Press the setting button, enter the internal menu, the default display for the P0, and then click the settings button, use up and down buttons to set the starting temperature.
P1: Set stop temperature
Press the setting button, enter the internal menu, the default display for the P0, use up and down button to change to P1, and then press the settings button, use up and down buttons to set the starting temperature
P2: Set temperature calibration
Press the setting button, enter the internal menu, use up and down buttons to change to P2, press the set button again, use the up and down button to do the calibration.
If the detetion temperature is above the actual temperature of 0.5°C, need to set the calibration temperature is 0.5°C
If the detetion temperature is below the actual tempeature of 1°C, need to set the calibration temperature 1°C
P3: Set delay start
Press the setting button, enter the internal menu, use up and down buttons to change to P3, press the set button again, use the up or down button to set delay time( Minutes ).
To control a water heater, heated water to 65 degrees to stop, when the temperature dropped to 50 degrees to start heating again
The first step: Determine the working mode for the heating mode, start the temperature
The second step: Long press “up” button, start temperature digital flash, set the starting temperature of 50 degrees
The third step: long press the “down” button to terminate the temperature digital flashing, set termination temperature of 65 degrees.
When setting the heating mode, if the set temperature value is set to the opposite, the output indicator will not light, the load will not work. If the above situation occurs after setting, you can check whether the set temperature value has the opposite.

DIMENSION

OVERVIEW

REFERENCE:

DOWNLOAD MANUALS:

Hexa CONTROL XH-W3002 TEMPERATURE CONTROL THERMOSTAT Data Sheet

Hexa CONTROL XH-W3002 TEMPERATURE CONTROL THERMOSTAT Data Sheet

wpx_thermostats

Recent Posts

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026

Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026 Details pertaining to the…

3 weeks ago

Online Slot Games For Money

Online Slot Games For Money Playing online casinos UK on a mobile device Spin the…

3 weeks ago

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026

Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026 Fantasy sports became a…

3 weeks ago

Online Casino Real Money Uk No Deposit

Online Casino Real Money Uk No Deposit Get ready to play the most realistic card…

3 weeks ago

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026

Sin88 Casino No Deposit Bonus Codes For Free Spins 2026 This can be part of…

3 weeks ago

How To Always Win Blackjack

How To Always Win Blackjack Casino offer terms and conditions in UK Here is how…

3 weeks ago