Period | Icon | Default Period Time | Default Period Temperature | |
Working Day | 1 | 06:00 | 20℃ | |
2 | | 08:00 | 15℃ | |
3 | | 11:30 | 15℃ | |
4 | | 12:30 | 15℃ | |
5 | | 17:30 | 22℃ | |
6 | 22:00 | 15℃ | ||
Weekend | 1 | 08:00 | 22℃ | |
2 | 23:00 | 15℃ |
Please refer to Wireless Wiring Centre User Manual (HWC018RF) for detailed wiring instructions. It is recommended that a qualified Electrician is consulted, or used for the installation of this product, in accordance with the current IEE Wiring and Building Regulations.
In “power off” state, first press and hold
No. | Symbols | Setting Item | Parameter Setting Function | Factory Default |
1 | SEN | Sensor control option (NTC) | 0: internal sensor 1: external sensor 2: internal control temperature, external limit temperature | 0: internal sensor (“Err” is displayed if selected wrongly, or NTC is faulty. Heating stops until corrected) |
2 | OSU | Temperature limit of external sensor | 5-99 oC | 42 oC |
3 | dlF | Return difference of temperature limit value of the external sensor | 1-9 oC | 2 oC |
4 | SUH | Set the upper-temperature limit value | 5-99 oC | 35 oC |
5 | SUL | Set lower limit temperature value | 5-99 oC | 5 oC |
6 | AdJ | Synchronise display the temperature reading | -5 oC to +5 oC | 0.5 oC |
7 | FrE | Anti-freezing function (only for water heating) | 00: anti-freezing function closed 01: anti-freezing function open | 00: anti-freezing function shut down |
8 | Loc | Keylock | 00: Unlock 01: All keys locked except power key 02: All keys locked | 00: Unlock |
9 | SNP | Alternate Parameter | 00 01: Active | 00 |
10 | FAC | Factory default | 08: Using current user settings 00: Restore factory default (set to 00 and press | 00 |
Note: The temperature limit of the external sensor is factory set at 42 oC (OSV). The return difference of this temperature is factory set at 2 oC (diF). When the temperature reaches 44 oC , the thermostat will switch the heating output off. When the temperature drops down to 40 oC , the thermostat will switch the heating output back on.
PRODUCT SUMMARY
This new design heating thermostat is designed to be used with the Hetta Wireless Wiring Centre HWC018RF. With a large LCD display it can be positioned within the building, without extra cables.
BUTTON DESCRIPTION | ||||||
KEY | DESCRIPTION | |||||
On / off | ||||||
Mode key: Press to switch between auto/manual time interval control. Allows temporary manual operation and time interval pre-set function | ||||||
| Time setting: minutes/hours/weeks | |||||
Raise temperature setting, programmed parameters | to increase | |||||
Lower temperature setting, programmed parameters | to decrease | |||||
Keylock Press |
Note: If the backlight is not on when the thermostat is in operation, this means the battery power is low, in which case please replace the batteries.
DOWNLOAD MANUALS:
HETTA HM01RF Wireless Programmable Thermostat USER MANUALS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…