HERZ

Herz F800-50 Wireless Thermostat User Manual

Herz 3 F800-50 Wireless Thermostat

Introduction

The Herz 3 F800 50 is a wireless thermostat. It serves for the measuring and regulation of temperature. The temperature is set by the knob. The thermostat regulates a preset temperature 24 hours per day. The thermostat can be locked against unwanted manipulation, as well as the regulation of temperature

Installation

The Her 3 F800 50 should be mounted in a dry indoor location. Choose a mounting location about 1.5 meters above the floor in an area with good air circulation. Avoid places with draughts, dead air spots and radiant heat from the sun or appliances. It should not be installed close to any metal structure or other objects that may obstruct radio signal transmissions.

  • Release the upper cover by pressing the plastic tab on the bottom side of the housing.
  • Mount the back part on the desired location
  • If the thermostat was purchased as a kit along with a receiving unit, connect the detector’s battery (pull out the red tape to activate the battery). Otherwise see section “Mounting the receiving unit”
  • Close the thermostat

Mounting the receiving unit

Install and connect the receiving unit to the heating system. If the receiving unit was purchased separately then thermostat have to be enrolled – enter enrolment mode on the receiving unit (see its manual) and connect the battery to the thermostat.

Settings and programming
Do the complete settings using the knob. The programming mode is entered by pressing the knob for two seconds.

General rules for programming:

  • Flashing of any icon on the LCD allows changing the option(s) or choosing the next item.
  • Perform choosing or changing by turning the knob
  • Confirm the selection or change by briefly pressing the knob
  • When the value of an item has been changed, then after this briefly press the knob and changes are saved. Then thermostat goes to the next item in the programming menu
  • After setting of the selected items, choose the parameter “OK” in the menu. By short pressing the system returns back to the previous menu.
  • If there is no manipulation of the knob for 30 seconds, it returns you back to the previous menu automatically.

The basic menu has four groups of settings:

  • LOC Locking the thermostat
  • OFF Switching off the thermostat
  • SEt3 Service menu
  • OK Saving the parameters and leaving the menu

LOC – Locking thermostat
To protect the thermostat against unwanted manipulation you can lock the thermostat. Enter the menu and press the knob on item LOo the options ON/OFF appear. “ON” enables the function OFF and blocks thermostat control. The thermostat is unlocked by the option OFF. Locking the thermostat is indicated on the LCD by the On Symbol.

OF – Switching off the thermostat
The thermostat is switched off by the OFF- option. Enter the menu and press the knob on the item OFF, the options ON/OFF appear. ON enables the function OFF and switches off the thermostat. This is indicated on the LCD by the text OFF. Although the thermostat has been switched off, it still measures and detects the antifreeze temperature. To turn the thermostat on enter the menu and choose the option OFF.

SEt3 – Service menu
The service parameters can be reprogrammed here. In a normal mode it is not necessary to change those parameters. The Service menu includes eight items. Items are modified by scrolling and pressing the knob.

  • Hysteresis is the accuracy to which the temperature is regulated. The setting is done via the HYst item in the adjustment menu. Turning the knob lets select you one of the following accuracy ranges: ‡0.1°C to +1°C (factory setting: #0.2°C) Example: If the accuracy is adjusted to +0.5°C and the temperature is set to 24°C, the thermostat switches the heating on when the temperature drops below 23.5°C and switches it off if the temperature goes above 24.5°C. In reality the temperature scatter can be slightly higher because of the temperature persistence of the room. Warning: Too high accuracy can cause the heating to turn on and off to frequently.
  • The item Stby sets the temperature which will be kept in the case of switching off their thermostat (item OFF). The Stby temperature is always at least 3°C higher than ALLo. The value of the Stby temperature does not have to be set higher than the t Lo temperature.
  • The t Lo item is the lower limit to which economical temperature can be set.
  • The t Hi item is the upper limit to which the comfort temperature can be set.
  • AL Lo is the lower critical temperature. When the temperature drops under the preset value, the thermostat sends an alarm report to the receiver and this state is indicated by a permanently lit (!) symbol. The
  • ALLo temperature is always at least 3°C lower than t Lo.
  • AL Hi is the upper critical temperature. When the temperature increases above the preset value, the thermostat sends an alarm report to the receiver and this state is indicated by a permanently lit (!) symbol.
  • The ALHi temperature is always at least 3°C higher than tHi. The reset function allows you to reset the device to factory settings (listed in the table). You can perform reset by selecting Res in the menu and pressing the knob and choosing the menu Res.
  • By pressing the OK item you are leaving the service menu and returning to the basic thermostat menu

Range of temperature settings

Settings item Range Factory settings Description
HYst 0.1°C to 1°C 0.2°C Hysteresis
t Lo +6°C to +40°C 6°C the lower limit of temperature
t Hi +6°C to +40°C 40°C the upper limit of temperature
AL Lo -9°C to +20°C 3°C Panic Alarm
AL Hi +30°C to +70°C 60°C Fire alarm

Adjustment ranges as depicted on a coordinate axis:

Specification

Power supply: 2x AA 1.5 V alkaline battery
Battery lifetime: typically 1 year
Temperature measurement: +6°C to +40°C
Temperature accuracy: ±0.1°C to ±1°C
Freeze alarm (Panic alarm): configurable from -9°C to +20°C
Fire alarm: configurable from 30°C to 70°C
Operational frequency: 868.1 MHz, Flexi protocol
Operational radio range: 100m (open area)
Operational temperature: -10°C to +70°C (low humidity)
Dimensions: 65 x 88 x 20 mm
According to: ERC REC 70-03

Herz

  • A-1230 Wien, Richard-Strauss-Straße 22
  • Telefon: + 43/(0)1/616 2631-0
  • Fax: + 43/(0)1/616 26 31-227
  • e-mail: office@herz.eu
  • www.herzeu

REFERENCE:

DOWNLOAD MANUALS:

Herz F800-50 Wireless Thermostat User Manual

Herz 3 F800-50 Wireless Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago