A programmable room thermostat is both a programmer and a room thermostat.
A programmer allows you to set “On” and “Off” periods to suit your own lifestyle.
A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
So a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs and preferences.
Setting a programmable room thermostat to a higher temperature will not make the room heat up any faster. How quickly the room heats up depends on the design and size of the heating system.
Similarly reducing the temperature setting does not affect how quickly the room cools down. Setting a programmable room thermostat to a lower temperature will result in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job.
The best way to do this is to set the room thermostat to a low temperature – say 18°C , and then turn it up by 1°C each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
You are able to temporarily adjust the heating program by overriding or using the temperature hold feature. These features are explained further on pages 17 and 18 of this manual.
Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may also prevent the thermostat from working properly.
Do
Mount the thermostat at eye level.
Read the instructions fully so you get the best from our product.
Don’t
Do not install near to a direct heat source as this will affect functionality. Do not push hard on the LCD screen as this may cause irreparable damage.
The neoStat 12v V2 is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation.
Step 1
Using a small screwdriver, slightly loosen the screw from the bottom face of the thermostat. Then carefully separate the front half from the back plate.
Step 2
Place the thermostat front somewhere safe.
Terminate the thermostat as shown in the diagrams on pages 28 of this booklet. Note: For time clock wiring connections, terminate as shown on page 35.
Step 3
Screw the thermostat back plate securely into the back box.
Step 4
Clip the front of the thermostat onto the back plate, securing it in place with the retaining screw.
This neoStat 12v V2 can either be used as a thermostat or a time clock. Thermostat mode is the default setting.
To change between thermostat or time clock modes, follow these steps.
The neoStat 12v V2 will revert to the main display screen for the selected mode.
For time clock mode instructions, first pair the time clock with the neoHub as explained on page 8, then turn to page 30.
To pair the neoHub with the neoApp, follow these steps.
The next step is to join the neoStat-xe V2 to the neoHub, we recommend joining the neoStat-e V2 located nearest to the neoHub first.
To add a neoStat-e V2, follow these steps;
Please note, you only have to pair the hub to your account once. To pair any additional neoStats, select ZONES, edit, then ADD ZONE.
NeoStats work using a mesh network, meaning neoStats have the ability to send & receive signals via other thermostats on the network. This signal is relayed from one thermostat to another until it reaches its destination. This communication method extends the communication range whilst offering increased network stability when compared with standard RF thermostats.
The Mesh symbol is shown when the device is communicating with the neoHub, if the mesh symbol disappears this indicates connection to the neoHub has been lost.
The neoStat-e V2 uses proximity to detect when you are about to use the touch keys. As you approach the neoStat-e V2, the touch keys and backlight will light up. This can be useful if you need to adjust the set temp or timer in a dark room.
Mode 1 – Thermostat
LCD Display
The neoStat-e V2 can be configured for different sensor options such as built in air sensor, floor sensor or both. The display will clearly indicate which sensor is being used by showing either “Room Temp” or “Floor Temp” before the actual temperature value.
When the neoStat-e V2 is set to use both the air & the floor sensor, the room temperature will be displayed by default.
To view the current floor temperature, press and hold the Left and Right arrow keys for 5 seconds, the floor temperature will then be displayed ……
To set the clock, follow these steps.
The neoStat-e V2 offers three program mode options; Weekday/Weekend programming, 7 Day programming and 24 Hour programming. There is also the option to use the thermostat as a Non-Programmable thermostat.
When thermostats are connected to the mesh network, the program mode for the system is configured by using the neoApp.
The thermostat is supplied with comfort levels already programmed, but these can be changed easily. The default times and temperature settings are;
07:00 – 21°C (Wake) 09:00 – 16°C (Leave) 16:00 – 21°C (Return) 22:00 – 16°C (Sleep)
If you only want to use 2 levels, you should program the unused levels to –:–
For Weekday/Weekend programming, the four comfort levels are the same for Mon-Fri, but can be different for Sat-Sun. For 7 Day programming each day of the week can have four different comfort levels. In 24 Hour mode all days are programmed with the same comfort levels.
Note: This new temperature is maintained only until the next programmed comfort level. At this time, the thermostat will revert back to the programmed levels.
Temperature Hold
The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period.
You will see the HOLD LEFT indication is displayed on screen.
The time will countdown the set duration and then revert to the normal program.
To cancel a temperature Hold, with hold selected on the main menu, press the tick key and then press tick again while Cancel is highlighted.
Locking the neoStat-e V2
The neoStat-e V2 has a keypad lock facility. To activate the lock follow these steps.
The display will return to the main screen and display the keypad lock indicator ……
Note: The keypad lock indicator is only displayed when the lock is active.
Unlocking the neoStat-e V2
To unlock the neoStat-e V2 press Tick once. The display will show 00:00 and you will need to enter the four digit pin number you set previously.
In this mode, the neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature (see page 23). If the heating is turned ON whilst in frost mode, the flame symbol will be displayed. To cancel the frost protect mode, navigate to the Power button again and press Tick.
The heating is indicated ON when the flame icon is displayed.
When the flame icon is absent, there is no requirement for heating to achieve the set temperature but the neoStat remains active.
To turn the neoStat-e V2 off completely, scroll to the Power Icon and hold the Tick key for approximately 3 seconds until the display goes blank ……
The display and heating output will be turned OFF.
To turn the thermostat back ON, press the Tick key once ……………………………………………………..
In thermostat mode, the holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 23).
The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return.
In time clock mode, the holiday function maintains the timed output as OFF.
Set a date & time for the holiday period to end, using the steps below;
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED
NOT BE ADJUSTED.
Feature 01 – Pairing To neoHub: This function is used to connect the thermostat to the neoHub.
Feature 02 – Switching Differential: This function allows you to increase the switching differential of the thermostat. The default is 1°C which means that with a set temperature of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C. With a 2°C differential, the heating will switch on at 18°C and off at 20°C.
Feature 03 – Frost Protect Temperature: This is the temperature maintained when the thermostat is in Frost Mode. The range is 07 – 17°C. The default is 12°C and is suitable for most applications.
Feature 04 – Output Delay: To prevent rapid switching, an output delay can be entered. This can be set from 00 – 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit: This function allows you to limit the use of the up and down temperature arrow keys. This limit is also applicable when the thermostat is locked and so allows you to give others limited control over the heating system.
Feature 06 – Sensor Selection: On this neoStat, you can select which sensor should be used. You can select between air temperature only, floor temperature, or both. When you enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to prevent the floor from overheating.
Feature 07 – Floor Temp Limit: This function is available when mode 06 is set to 03 or 04. You can set a floor limiting temperature between 20-45°C (28°C is the default setting).
Note: Air Sensor only MUST NOT be used to control electric under-floor heating. Floor Sensor or Both should be used.
Feature 08 – Optimum Start: Optimum start will delay the start up of the heating system to the latest possible moment to avoid unnecessary heating and ensure the building is warm at the programmed time. The thermostat uses the rate of change information to calculate how long the heating needs to raise the building temperature 1°C (with a rate of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1°C) and starts the heating accordingly.
Feature 09 – Rate of Change: Number of minutes for 1°C temperature rise.
Feature 10 – Not used on this model.
Feature 11 – Not used on this model.
Feature 12 – Program Mode: Non-Programmable, Weekday/Weekend (5/2),
7 Day Programming or 24 Hour. The thermostat offers three programming modes and the option of configuring it to work as a non-programmable thermostat.
Feature 13 – Temperature Format: This function allows you to select between °C and °F.
FEATURE | DESCRIPTION | SETTING | |||
01 | Pairing | Used to add zone to the neoHub | |||
02 | Switching Differential | 00.5 = 0.5°C 01 = 1.0°C (Default) 02 = 2.0°C 03 = 3.0°C | |||
03 | Frost Protection Temperature | 07° – 17°C (12°C = Default) | |||
04 | Output Delay | 00 – 15 Minutes (00 = Default) | |||
05 | Up/Down Temperature Limit | 00° – 10°C (00 = Default) | |||
06 | Sensor Selection | 00 = Built in Sensor (Default) 01 = Remote Air Sensor 02 = Floor Sensor Only 03 = Built in & Floor Sensor 04 = Remote Air & Floor Sensor | |||
07 | Floor Temperature Limit | 20°C – 45°C (28°C = Default) | |||
08 | Optimum Start | 00 – 05 Hours (00 = Default) | |||
09 | Rate of Change | Minutes to raise by 1°C | |||
10 | Not used on this model | ||||
11 | Not used on this model | ||||
12 | Program Mode | 00 = Non – Programmable 01 = Weekday/Weekend (Default) 02 = 7 Day Programming 03 = 24 Hour Mode | |||
13 | Temperature Format | 00 = °C, 01 = °F (00 = Default) | |||
26 |
If you need to re-calibrate the thermostat, follow these steps.
When terminated for thermostat operation the screen will display an error code if a fault is detected.
Floor Temperature Sensor Probe Type
The neoStat-e is supplied with a 10K floor sensor probe & is compatible with two other common probe values which are 12K or 15K.
To change the neoStat-e to use a different probe type, follow these steps;
Note: This change should only be carried out by an experienced technician who has accurately verified the probe value being used.
This product must only be installed by a qualified electrician and comply with local installation regulations.
To reset the device to factory default settings, follow these steps:
Press and hold Tick to turn the display OFF ……………………………………………………
The neoStat will revert to the main display screen for the selected mode.
Note: Factory reset will cancel all parameters that were entered during the set-up and pairing operations. These processes must be repeated after the factory reset is completed.
LCD Display
To program the switching times, follow these steps.
To override the timed output, follow these steps.
Feature 01 – Pairing To neoHub: This function is used to connect the time clock to the neoHub.
Feature 02 – Weekday/Weekend (5/2), 7-Day Programming or 24-Hour Mode: The time clock offers three programming methods;
Wiring Diagram – Time Clock Mode
This product must only be installed by a qualified electrician and comply with local installation regulations.
Want More Information?
Call our support team on +44 (0)1254 669090
Or view technical specifications directly on our website: www.heatmiser.com
Heatmiser UK Ltd
Units 1-5 Hurstwood Court, Mercer Way Shadsworth Business Park, Blackburn, Lancashire, BB1 2QU, United Kingdom.
Twitter: @heatmiseruk
Facebook: facebook.com/thermostats
Download manual:
Heatmiser neoStat-e V2 Electric Floor Heating Thermostat USER MANUAL
Other Manual:
Heatmiser neoStat-e V2 Electric Floor Heating Thermostat PRODUCT SPECIFICATION GUIDE
Heatmiser neoStat-e V2 Electric Floor Heating Thermostat USER MANUAL
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…