Heatmiser

Heatmiser DS-SB v3 Room Thermostat Installation Guide

Heatmiser DS-SB v3 Room Thermostat

Introduction

The Heatmiser DS-SB is a flush mounted set-back thermostat and is ideal for those who want a simple but energy efficient temperature control system. The DS-SB features a set-back function. This function automatically reduces the set temperature by 4°C when no time clock signal is detected.
The DS-SB thermostat has been designed to work in conjunction with the Heatmiser UH8 wiring centre and TM4 Programmer, but can also be used as a standalone dial thermostat.

Remote Sensor

The Heatmiser DS-SB provides the option to work with a remote temperature sensor. When a compatible remote sensor is connected, the thermostat will automatically switch from using its internal sensor to use the remote sensor instead. This function is ideal for controlling bathrooms or when the thermostat needs to be installed in a different area of the building to that being measured and controlled.

Heatmiser Thimble Sensor (not included)

Switching Differential

The Heatmiser DS-SB offers 1, 2 and 3°C switching differential.
With a 1°C switching differential the heating will switch on 1°C below the set temperature and will turn on when the set temperature is reached.
A 2° differential will turn the heating on 2°C below the set temperature.
3°C will switch the heating on 3°C below the set temperature.
To set the differential, you should set the DIP switches according to the table below. The DIP switch can be accessed from the back of the thermostat (shown below).

  1. 1 °C Switching       Switch 1 & 2 OFF
  2. 2 °C Switching      Switch 1 ON and Switch 2 OFF
  3. 3 °C Switching      Switch 1 OFF and Switch 2 ON

Installation

IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, TURN OFF THE POWER TO THE HEATING SYSTEM BEFORE COMMENCING INSTALLATION.

  1. Using a small screwdriver, slightly loosen the screw from the bottom face of the thermostat. You can then carefully separate the front half from the back plate.
  2. Terminate the thermostat as shown in the wiring diagram.
  3. Screw the back plate securely back onto the wall.
  4. Clip the front of the thermostat onto the back plate, securing it in place with the retaining screw.

Setting The Temperature

To change the set point, rotate the dial until it points to the desired temperature.

Off Mode

Placing the thermostat switch into position 0 will turn OFF the heating completely.

Constant Mode

The time clock can be bypassed by placing the switch into position 1. In this position, the thermostat will ignore the time clock input and will continuously control to the set temperature.
This feature can be used to extend the heating period without the need to adjust the time clock program.

Set-back Operation

The Heatmiser DS-SB offers a set-back function that automatically reduces the set temperature by 4°C.
To make use of the set-back function, a 230v time clock is also required on the system. Place the thermostat slide switch into the time clock position.
When the thermostat receives a 230v signal from the time clock it will control the temperature according to the dial setting.
When no 230v signal is received from the time clock, the thermostat will operate in set back mode and automatically reducing the set temperature by 4°C.

LED Indication

Right LED
The right LED is the power LED. It is a two colour LED and is used to indicate the me clock / set-back status.

Left LED
The left LED indicates the heating status. It illuminates when the thermostat is calling for heat.

Wiring Diagram

Want More Information?

Call our support team on: +44 (0)1254 669090
Or view technical specifications directly on our website: www.heatmiser.com
Heatmiser UK Ltd
1 – 5 Hurstwood Court, Mercer Way,
Shadsworth Business Park, Blackburn,
Lancashire. BB1 2QU, England

Reference

Download manual:

Heatmiser DS-SB v3 Room Thermostat Installation Guide

Other Manual:

Heatmiser DS-SB v3 Room Thermostat Product Specification Guide

Heatmiser DS-SB v3 Room Thermostat Installation Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago