The NGT thermostat can switch your underfloor heating system on and off at predetermined times throughout the week. Each day of the week is split up into four separate periods, each of which can have a different target temperature. This allows you to lower the temperature in rooms that are unoccupied at different times reducing your energy usage without reducing your comfort. Your NGT thermostat comes ready and programmed with a default schedule which is suitable for most homes. If you do not change the settings your thermostat will follow the default schedule. Your thermostat also features an adaptive function that learns how long the floor takes to heat up and cool down as the seasons change and takes this into account when turning the heating on and off. This ensures the room is always up to temperature at the desired time. The adaptive functions fuzzy logic takes three days to learn the heat characteristics of the room before it operates efficiently
First-time settings
The first time you switch the thermostat on the time, application, floor type and load must be set. The menu will automatically guide you through the process.
The next menu allows you to select the application you want the thermostat to run on.If the thermostat is in the room to be heated select Room/limit. If the thermostat is outside of the room to be heated select Floor. Once you have chosen your setting press OK. You now need to select your chosen floor covering so the thermostat can take this into account in it’s settings. Select your chosen floor covering and press OK. You now need to enter the loading of the system, this is the kW output of the heating system powered by the thermostat. Select the appropriate loading and then press OK. The thermostat is now ready for use and your underfloor heating will operate following the pre-programmed 4-event schedule. See Factory Settings for full details of this.
The on/off button allows you to turn the thermostat on “I” and off “0” by sliding the button up and down. When the thermostat is switched off “0”, the relay disengages and your underfl oor heating system will not heat up whatever the temperature. All settings, including time and date, will be saved into the thermostat’s memory. The thermostat is simple to use and program by using the navigation buttons.
The function of each button is indicated above the button in the display.
Back
In various parts of the menus and submenus, you will find the Back menu item.
Use Back to return to the previous screen
Exit
Exit returns you to the main operating screen.
The thermostat features three different modes of temperature control:
The menu allows you to select the following options:
4-event settings
The four-event settings allow your thermostats to control the temperature automatically in accordance with the program of your own choice. You can select temperature settings for four different periods during the day:
The thermostat is pre-programmed with a 4-event schedule for simple and economic heating control, see Preset schedule under
Factory settings. The schedule can be easily changed in the following way:
In the user settings menu you can change the following items:
Time and date
Press OK and set the actual time in hours and minutes.
The date will then be displayed. Set the date and confirm with OK.
Child lock
Display settings
Allows you to select what is shown on the main display.
Press the OK button to select or deselect the display options. Then select Exit in the menu to return to the initial display and view your chosen settings..
4-event schedule
This setting allows you to choose the format of the 4-event settings to suit your requirements.
Energy monitor
The energy monitor allows you to view your underfloor heating system’s energy consumption for the past 2 days, months or years.
Press OK for the chosen period. The value in per cent (%) shows the relative amount of time the heating has been on. The actual running cost shown on the screen is a calculated figure. To ensure this figure is correct you should ensure the information for the currency, price per kWh and load are correct.
The Engineering settings menu contains the following options:
Offset temperature
It the temperature the thermostat displays does not correspond to the actual temperature in the room you can adjust the sensor.
Press OK and then enter the correct temperature for the air or floor. The thermostat will then automatically correct itself in the future.Please note that the thermostat anticipates rises and drops in temperature by a few minutes so that it does not over-run the target temperatures. This can lead to the temperature reading shown on the thermostat being slightly above or below the actual readings but is perfectly normal. Confirm with OK.
Adaptive function
The adaptive function ensures that the required temperature has already been reached when you get up in the morning or come home from work. If this function is operating and you have set your underfloor heating to come on at 6:30 am, the fl oor will already be warm by that time, rather than just starting to heat. The adaptive function takes a few days to learn the heat characteristics of your room before it functions correctly. Press OK and set the function to On. Confirm with OK.
Application
Set the type of regulation used.
There are two options:
Press OK and select the required application. Confirm with OK.
Temperature scale
The temperature scale allows you to set maximum and minimum floor temperatures and the thermostat will ensure that the floor never operates outside of these limits. Even if a higher target temperature is set for the room, the thermostat will stop the floor from overheating. This is particularly useful for systems used beneath wooden or laminate floors.
Press OK to highlight the minimum temperature. Use the up or down button to select the minimum permissible temperature. Press OK and then select the maximum permissible temperature. Confirm the settings with OK.
Backlight
The backlight menu allows you to choose when the display is lit up. The options are as follows:
Floor sensor
The NGT thermostat can operate with many different models of floor sensors. This allows you to replace most older underfl oor heating thermostats with the NGT thermostat without having to replace the floor sensor. The value of your original fl oor sensor can be set in this menu, and this value is usually listed in the instructions that were supplied with the previous thermostat. If you have any questions on this function please contact Heat Mat on 01444 247020.
Factory reset
This menu allows the factory settings to be restored. Your settings will be lost, see Factory settings.
Press OK and choose Reset in the menu.
Confirm with OK.
Information
The information screen displays Heat Mat’s contact details, the current temperatures (and off set) of the two sensors, the software version of your thermostat and the individual model number, which is used for warranty purposes.
Back
In various parts of the menus and submenus you will fi nd the Back menu item.
Use Back to return to the previous screen
Exit
Exit returns you to the main operating screen.
Error messages
If a fault or error occurs the thermostat will display an error code message as follows:
Preset schedule
Day 1-5 | |||
Event | Time | With floor sensor | With room sensor |
Day | 06:00-08:00 | 25°C | 20°C |
Out | 08:00-16:00 | 20°C | 15°C |
Home | 16:00-22:30 | 25°C | 21°C |
Night | 22:30-06:00 | 20°C | 15°C |
Day 6-7 | |||
Event | Time | With floor sensor | With room sensor |
Day | 08:00-23:00 | 25°C | 21°C |
Night | 23:00-08:00 | 20°C | 15°C |
Download Manuals
HEATMAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL
HEATMAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…
Honeywell Prestige THX9000 Touch-screen Thermostat About your new thermostat Your new thermostat is pre-programmed and…