DESCRIPTION OF CONTROLS

  • selection of functions
  • = selection of temperatures
  • = confirmation (ENTER), information present temperature (tE: A), present time (CL:O), the sum of operating hours (SU: MA), and day (dE:n)
  • the setting of temperature, time, functions

DISPLAY DESCRIPTION

OPERATING INSTRUCTIONS

After a connection in the 230V socket is TS10 immediately ready for use? If sign dO: bI is flashing on the display, the backup battery is not fully charged and it is necessary to let the TS10 in 230V-socket charge for a minimum of 2 days (a full charge takes about 4 days). After charging it is possible to remove TS10 from the socket without losing the actual time and you can provide the programming outside the 230V socket. (Maximal backup time is 100 hours). If we disconnect TS10 from the network 230V, the TS10 comes to standby mode and only actual time will be shown on display (the colon symbol will not be flashing) and the buttons will be functionless. The activation of the buttons you can make by pressing the button. When the sign dObI will be permanently shown on display, it is not possible to make any settings on TS10 without connection into 230VAC If the TS10 is not in a 230V socket the showed temperature is 2 °C lower than real actual temperature

BASIC FUNCTIONS

  • After pushing the  button you can select the following functions by pushing
  • AUTO thermo-switch socket works according to the program as set
  • MANU serves for manual setting of temperature ( the selection by or by  buttons), the temperature should be constant up to the next change of mode.
  • CLO: setting of present-day and time.
  • PAr: setting of parameters (constants).
  • PROG programming mode
  • OFF in this mode is TS10 permanently switched off.

Proceed during programming

Before the programming itself, it is necessary to set present day, time, and parameters (constants), namely in the following way

Setting of current day and time – “ CL:O “ function

  • Press the button, by pressing select CLO (CLOCK) function and confirm by 
  • Indication of hours blinks on the display, use  buttons to set required data and confirm by button.
  • Use the same method for minutes and day (d:1 represents Monday, d:2 Tuesday, and d:7 Sunday)
  • After the completion of the setting, press the button to return

Setting of parameters (constants) – “ PA:r “

PA:r1 display option

  • Press the button , button by pressing select Par (Parameters) and confirm by 
  • pA:r1 shows on the display, confirm by  and with using of buttons select display options in basic mode:
  • t information on the present temperature
  • C current time
  • the selection is again confirmed by pressing

PA:r2 economic temperature (factory setting 17°C)

  • PA:r2 shows on the display
  • confirm by and with using of buttons set economic temperature and press the button to confirm

PA:r3 comfort temperature (factory setting 23°C)

  • PA:r3 shows on the display
  • confirm by and with using of buttons set comfort temperature and press the button to confirm

PA:r4 party temperature (factory setting 25°C)

  • PA:r4 is showed on the display
  • confirm by  and by pressing buttons set
  • party temperature, again confirm by pressing I

PA:r5 HYSTERESIS (factory setting 0,5°C)

  • PA:r5 is shown on the display
  • confirm by and by pressing buttons set hysteria sis in the range from 0.1°C to 6°C, again confirm by
  • HYSTERESIS = temperature difference for switching on/off the appliance

PA:r6 summer mode = switching on/off the air-conditioner (COOLING)

  • PA:r6 is showed on the display, press
  • can be selected in summer, when we need to switch connected air-conditioner on at defined temperature. In this mode, the
  • hysteresis will act in inverse way than in the mode for heating
  • (if PA:r5=0.5 and required temperature is 23°C, the socket switches on at the temperature of 23.5°C)
  • by pressing select mode, then press  button.

PA:r9 number of firmware version/ reset of factory settings (see page 5)

  • PA:r9 is showed on the display
  • this parameter is only of informative character a shows the number of firmware version
  • press or  to return to function selection.

Programming- “ PROG “ function

    • press  and by buttons select PROG function and confirm by pressing
    • by pressing  select the day, which should be programmed according to the following table
    • when the day is selected, press and symbol 1:U1 is displayed so that you can set the first time interval

 

  • by pressing set the time of the first change (min. step: 10min.)
  • by repeated pressing of the assigned required temperature to this time
  • again confirm by pressing  and the display automatically shows symbol 1:U2 for the second time interval in the first day.
  • this procedure should be repeated until all time intervals (max.6) are set and afterward leave the programming mode by pressing
  • select AUTO function and the socket starts to function according to the defined program

 

Status indication of TS10:

  • AUTO (or MANU) is shown = output is switched on
  • AUTO (or MANU) blinks = output is switched off

EXAMPLE of program setting

  • Set on 18°C (PA:r2)
  • Set on 23°C  (PA:r3)
  • Choose a program for the whole week d1:7(Prog)
  • 17:U1 assign time 6:00 and temperature
  • 17:U2 assign time 9:00 and temperature
  • 17:U3 assign time 13:00 and temperature
  • 17:U4 assign time 19:00 and temperature
  • Leave the programming regime by pressing the button and selecting AUTO mode.

Short-term change of temperature in AUTO mode:

By simply pressing of buttons in AUTO mode, it is possible to make a short-term change in the required temperature. TS10 will maintain this temperature up to next temperature change as defined in the program.

OFF “ function:
Press the  button, by pressing button select OF: F function, and confirm by  button. In this way, TS10 is permanently switched off. In this mode, symbols OFF and antifreeze temperature 3°C are shown alternatively on the display. To cancel this function, press  the button and select a different mode using of  buttons.

Child lock:
It serves for keyboard blocking, as a protection against unauthorized handling. By simultaneous pressing of  and buttons the keyboard is locked (buttons are inactive). Message LOC (LOCK) is shortly displayed. The function can be canceled, e.g. the keyboard unblocked, by simultaneously pressing of the and+ buttons (the buttons are again functioning now).

RESET – restoring the default settings

Erasing of programs:

  • Press the button, by pressing  select function PA:r and confirm by  button.
  • By pressing the buttons to select PA:r9, confirm by
  • Simultaneously press and- buttons, it will restore the factory settings!
  • Note: Use only when necessary, all saved changes will be deleted

Installation

  • Connect TS10 in 230V/50 Hz socket.
  • Program it according to instructions (register respective data in the table).
  • Connect the heating body you want to regulate.

Error messages
If the following error message is shown on the display, contact immediately the manufacturer (it is dealing with a failure of the temperature sensor).

Table for registration of your programs

THERMO-SWITCH SOCKET

TS10 is a digitally switched socket for automatic regulation of electrical heating systems (direct heating bodies, towel driers, fires) in family houses, flats, and offices. Up to four-time intervals with two temperature levels can be set for each day.

Further advantages:

  • different temperature program for each day
  • the possibility to set 2 temperature levels
  • simple control and programming
  • possibility to make a short-term change in program temperature
  • permanent switching off of the appliance ( OFF )
  • temperature regulation at steps of 0,5°C
  • well-arranged display
  • back-up battery NiMH 2,4 V, for more than 100 operating hours

TECHNICAL PARAMETERS

  • Power supply 230 V/ 50 Hz
  • Number of adjustable temp. 3 different temperatures for each day
  • Hysteresis 0.1 to 6°C with steps of 0.1°C
  • Minimal programming time 10 minutes
  • Range of possible temp. 3 to 40°C
  • Step of temperature setting step of 0.5°C
  • Minimal step of indication 0.1°C
  • Measurement accuracy ± 1°C
  • Back-up battery NiMH 2.4 V/ > 100 hours
  • Output relay, max. 16 A

Heat decor

  • ELEKTROBOCK CZ s.r.o.
  • Blanenská 1763
  • Kuřim 664 34
  • Tel./fax: +420 541 230 216
  • www.elbock.cz

Reference

Download manual:

Heat decor TS20 THERMO-SWITCH SOCKET THERMOSTAT user manual

Heat decor TS20 THERMO-SWITCH SOCKET THERMOSTAT user manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago