Read this manual carefully before starting to use the device. Keep the manual so you can refer to it at a later date should you need to.
The MAXI Radiator Thermostat is a component of the MAX! System. It is responsible for regulating your radiators. All configuration settings are made via the user-friendly MAX! Software. Different settings can be made for individual rooms. Communication between MAX! Components is bi-directional. This ensures that the information sent reaches the recipient. The MAX! Radiator Thermostat is used to regulate a standard radiator valve. The device may only be operated indoors and must be protected from the effects of dampness and dust, as well as solar or heat radiation. Using this device for any purpose other than that described in this operating manual does not fall within the scope of intended use and shall invalidate any warranty or liability. This also applies to any conversion or modification work. This device is in- tended for private use only. For more information about the MAX! System and the available components, please go to www.hama.com.
The service life of new alkaline batteries is approximately two years. A battery symbol (
The radiator thermostat can be mounted on all standard heating valves. There is no need to drain away water or to fiddle around with the heating system. Start by removing the old thermostat dial.
Some valves require the use of an adapter. Adapters for Danfoss valves (RA, RAV, RAVL) are supplied with the product. For more details, please see the list of adapters on page 16.
Once the batteries have been inserted, the motor reverses; meanwhile “InS” and the activity symbol (
The actuator performs an adapter run. “AdA” and the activity symbol (
If the adapter run has been initiated prior to mounting or if an error message (F1, F2, F3) is displayed, press the Boost button; the motor reverses to the “InS” position. If the MAX! The radiator Thermostat has not been taught in on the MAX! Cube, the device automatically switches to manual operation (Manu). Teach-in mode can be activated even whilst “InS” is still displayed.
In order to enable communication between MAXI Components. the devices have to be taught-in to one another.
IMPORTANCE
The MAX! Radiator Thermostat can be reset to the initial state manually. Restoring the initial state deletes all settings and information about taught-in devices.
To switch between operating modes, press and immediately release the Auto/Manu button (the operating modes only become available for selection once the installation is complete).
If the operating mode is changed on one device in a room, this change is applied on all radiator thermostats assigned to that room.
The boost function makes use of human sensations of heat. When the function is activated, the heating valve opens immediately for 5 minutes at 80% (factory setting). You can feel the heat from the radiator immediately and at the end of the 5 minutes, the room continues to heat up. If you arrive home earlier than usual and want to heat the room up quickly, or you need some extra heat in the morning after a shower, then the boost function will help you with this.
The radiant heat will not have an immediate effect if the radiator is covered or concealed (e.g. by a sofa).
If the duration of the boost function (e.g. via the MAX! Cube) is set so that the display exceeds 999 seconds, the display value switches from seconds to minutes.
The actuator reduces the temperature in the room automatically during ventilation, in order to save on heating costs. During ventilation, the window open symbol (
Without MAX! Window Sensor:
A MAX! Radiator Thermostat is able to automatically detect a sharp fall in temperature caused by ventilation (temperature fall detection). The temperature is then reduced to 12’C for 15 minutes (default factory setting).
With MAX! Window Sensor:
When a MAX! A window Sensor is used, the opening and closing of a window is detected at the precise time it occurs. Whilst the window is open, the temperature is reduced to the factory setting of 12’C. When the MAX! Window Sensor detects the closing of the window, all MAX! Radiator Thermostats installed in the room are immediately reset to their original mode.
The open-window temperature and time can be set via the MAX! Software. Temperature fall detection without a MAX! Window Sensor can also be deactivated (by setting the duration to O minutes) via the software.
When a MAX! Window Sensor is taught in, the MAX! The radiator Thermostat does not react to a temperature fall.
The current temperature is displayed during normal operation, along with the mode. In the example on the right, the MAX! The radiator Thermostat is in automatic mode (Auto) and the comfort temperature {
The operation can be blocked on the device.
Battery life can be prolonged by switching the heating off in summer. To achieve this, the valve is opened fully and the calcification protection function continues to run. To activate this, proceed as follows:
If the room does not need to be heated, the valve can be closed. The valve is only opened if there is a risk of frost. The calcification protection function continues to run. To activate this, proceed as follows:
The electronic MAX! Radiator Thermostat has the advantage over mechanical thermostat dials in that it can protect against the threat of valve calcification automatically. To do this, it carries out fully automatic routine descaling once a week. During this brief period, when the valve opens and closes once, the operation is not possible.
Routine descaling is factory-set to run on Saturdays at 11 in the morning. “CAL” is displayed during routine descaling; you can set the day of the week and the time of day via the MAX! Software.
Error code on the display | Problem | Solution |
Battery symbol ( | Battery voltage too low | Replace batteries |
F1 | Valve drive sluggish | Check the installation; check whether the pin on the heating valve is stuck |
F2 | Stellbereich zu groB | Check the fastening of the actuator |
F3 | The actuating range is too narrow | Check the heating valve; check whether the The valve pin is jammed |
F4 | A MAX! Cube has already been taught-in | Reset the device and repeat the teach-in procedure |
Symbol for radio synchronicity flashing slowly ( | Connection to taught-in MAX! Components lost | Check the power supply to taught-in MAX! Components |
LOC | Operating block activated | Follow the instructions in the section entitled , Child-proof lock/Operating block” to deactivate the operating block |
CAL | Routine descaling is active | For automatic function, see the section entitled ••Routine descaling” |
The symbol for radio synchronicity flashing lastly ( | The duty cycle has been exceeded | The longest period to wait before sending again would be an hour |
Manufacturer | Image | Adapter |
Heimeier, MNG, Junkers, Landis&Gyr ,,Duodyr”, | An adapter is not | |
Honeywell-Braukmann, Oventrop, Schl6sser, | required for M30x1.5 | |
Simplex, Valf Sanayii, Mertik Maxitrol, Watts, | valves | |
Wingenroth f’,Niroflex), R.B.M., Tiemme, Jaga | ||
Danfoss RA | Supplied with device | |
Danfoss RAV | Supplied with device | |
Danfoss RAVL | Supplied with device |
Other adapters are available as accessories.
Subject to technical changes.
After the implementation of the European Directive 2002/96/EU and 2006/66/ EU in the national legal system, the following applies:
Electric and electronic devices as well as batteries must not be disposed of with household waste. Consumers are obliged by law to return electrical and electronic devices as well as batteries at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details to this are defined by the national law of the respective country. This symbol on the product, the instruction manual or the package indicates that a product is subject to these regulations. By recycling, reusing the materials, or other forms of utilizing old devices/ Batteries, you are making an important contribution to protecting our environment.
Hereby, Hama GmbH & Co. KG, declares that this 00111933 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. See www.hama.com for a declaration of conformity according to R&TTE Directive 99/5/EC guidelines.
Distributed by Hama GmbH & Co KG
0-86651 Manheim/Germany
+49 9091 502-0
www.xavax.eu
Download Manual:
Hama Xavax Radiator Thermostat Operating Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…