Warning: High voltages may be present! Be sure to turn off the power at the breaker panel or unplug the heater and/or air-conditioning unit before you begin installation or disconnect any wires. |
The Nest Power Connector is a simple, easy-to-install C-wire substitute for Nest thermostats. It allows the thermostat to access power through the existing thermostat wiring without pulling new wires. And it requires only one connection at the furnace, air handler, or zone controller.
Systems
For use with 24 VAC HVAC systems only. Not compatible with millivolt or high-voltage systems.
Technical specifications
Before you begin, watch the installation video at g.co/nest/powerconnectorinstall.
The Nest Power Connector is installed between the thermostat wiring and the rest of the HVAC equipment.
If the system has one thermostat, you’ll need to install the Nest Power Connector at the furnace or air handler.
If the system has more than one thermostat in a zoned system, you’ll need to install the Nest Power Connector at the zone controller. One Nest Power Connector is required for each Nest thermostat. At the furnace or air handler, locate the place where the thermostat wiring connects to the HVAC equipment. This is typically at a control board, but in some systems, especially furnaces, there is no control board. In this case, the thermostat wiring joins at a series of wire nuts (or similar). It’s sometimes necessary to remove a secondary cover inside the HVAC equipment to access this location.
In a zone controller, locate the appropriate wiring for the thermostat the Nest Power Connector will work with.
If it isn’t, follow the instructions provided with the thermostat to complete installation.
A. There’s no update needed for the Nest Thermostat E or the Nest Learning Thermostat (3rd gen). B. Nest Thermostat (2020) needs to run version 1.1 or later. On the device, go to Settings > Version > Update.
The Nest Power Connector is installed or connected at the same place where all the standard thermostat connections are normally made, at the furnace, air handler, or zone controller. See Installation on page 5 for more information. Open the cover at this location and find where the Nest Power Connector should be installed.
A. Heating and cooling system
Installation diagram
Cooling and heating system
B. Cooling-only system
Your system may have extra wires, like a G wire (to the thermostat) and C and Y wires (to the compressor). Keep them connected. Properly terminate any loose wires.
Optional: Use the sticky pad to attach the Nest Power Connector to the panel.
Installation diagram
Cooling-only system
C. Heating-only system
Your system may have extra wires, like a G wire (to the thermostat). Keep them connected. Properly terminate any loose wires. Optional: Use the sticky pad to attach the Nest Power Connector to the panel.
Installation diagram
Heating-only system
D. If no C terminal is present in the HVAC system
You’ll need an external 24 VA/20 VA transformer and additional wire nut/lever lock connectors.
Installation diagram
If no C terminal is present in the HVAC system
Once you’ve finished installing the Nest Power Connector, close the covers to the HVAC equipment, then turn on the power. There is often a safety switch controlled by the cover that will prevent operation until it is replaced.
“Taco” zone controllers
“Taco” zone controllers are more common for hydronic multi-zone heat-only systems.
No Wi-Fi for Nest Thermostat software update
To work with the Nest Power Connector, the Nest Thermostat will need a software update to version 1.1 or later. This update can only be made over Wi-Fi, so if the thermostat isn’t connected to Wi-Fi yet, follow the instructions from the Google Home app to get started. You can also use a mobile hotspot to connect to the internet. The user account can be removed from the thermostat after the software update is complete.
Millivolt systems
The Nest Power Connector and Nest thermostats are incompatible with millivolt heating systems. These systems often have the thermostat wiring connected to a gas valve with terminals labeled Th, Tp, and Th.
To confirm that a system is millivolt, measure the voltage across the thermostat terminals/wiring while the system power is active. A millivolt system will read ~0.5 VDC. Compatible 24 VAC systems will read between 20 and 30 VAC.
Power errors before installation
On the Nest Thermostat, E197, N260, or N261 errors may be present before installation. These errors can be resolved by correctly installing the Nest Power Connector or a common wire.
Other wires are present during installation
In some systems, particularly those with cooling, it’s common to have a second 2-wire bundle connected to the control board that controls the A/C compressor. Leave these and any other attached wires in place. The Nest Power Connector is only installed between the incoming thermostat wiring and the rest of the HVAC equipment.
“No Power” errors after installation
The thermostat is not receiving power. Confirm that the power is switched back on and that the HVAC equipment cover is closed (there’s often a safety switch controlled by the equipment cover). Confirm the system fuses and check and tighten all connections.
“Low Power” (N260/N261) errors after installation
N260/N261 in the Nest Thermostat. These errors can be resolved when the Nest Power Connector is correctly installed with the thermostat. Confirm that the Nest Power Connector is installed at the correct location and to the correct wires. Check that all wires are connected properly.
Nest Power Connector not detected
If the Nest Power Connector is not detected by the Nest Thermostat after running a power test, go to Settings > Equipment > Power Connector > Power Test:
On the Nest Thermostat, the Power Connector is not shown under Settings > Equipment
The Nest Thermostat may need a software update. Check for an update at Settings > Version > Update and confirm the thermostat has version 1.1 or later.
E297 errors on the Nest Thermostat after installation
The Nest Thermostat may need a software update. Check for an update at Settings > Version > Update and confirm the thermostat has version 1.1 or later.
Nest Thermostat wires not detected after installing the Nest Power Connector
Run a Power Test on the thermostat from Settings > Equipment > Power Connector > Power Test. Next, try to activate the function controlled by the undetected wire(s) (for example, heating or cooling) by changing the target temperature and thermostat mode. You can also try to run the fan from Settings.
HVAC equipment terminals not labeled
Identify the wires and colors used at the thermostat for R, W, and Y and match those corresponding wires to label the terminals at the HVAC equipment.
Google Nest GVNZ4 Nest Power Connector Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…