The room temperature controller is used to control the temperature in closed rooms, such as apartments, schools, lecture halls, workshops etc.
Installation site
Attention Installation and mounting of electrical devices may only be carried out by a qualified electrician.
If the mounting and installation instructions are not complied with, a danger of fire and other dangers can arise. The room temperature controller is mounted in a 58-mm flush-mounted box in accordance with DIN 49 073.
To install the room temperature controller, proceed as follows:
Connect all cables in accordance with the wiring schematic (see Page 10). If this is not done, great temperature fluctuations will result, as the room temperature controller cannot work properly. An earthed connection is not required, as the device is double insulated.
Attention Errors during connecting can lead to damage to the controlling device! No liability is accepted for damage caused by incorrect connection and/or improper handling!
Key to wiring diagram
Two setting rings are found in the setting knob. You can set the temperature limits as desired with them.
The temperature controller is set to the maximum setting range of 5 °C to 30 °C at the factory.
Setting procedure
To set the temperature limits (in this example: min. 8 °C, max. 23 °C):
When commissioning the room temperature controller, note that the thermo-bimetal requires a certain amount of time to adjust to the room temperature. This is why the switching point will deviate from the room temperature immediately after mounting or after night-time heating reduction switches off. The switching point is not precise until after one to two hours of operation. For quick initial heating and to shorten the initial adjustment, we recommend setting the selected temperature higher than desired. Once the temperature has been reached, the temperature setting can be reset to the desired setpoint.
Night-time heating reduction
We recommend performing night-time heating reduction of approx. 4 K automatically with a time-controlled signal.
Temperature setting scale
The scale for the temperature setting is found on the cover of the room temperature controller and is used for visual orientation when setting the temperature (from min. 5 °C to max. 30 °C).
The warranty is provided in accordance with statu-tory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade).
They will forward the devices to the Gira Service Center.
Gira
Giersiepen GmbH & Co. KG Elektro-Installations-Systeme
Postfach 1220
42461 Radevormwald
Deutschland
Tel +49 (0) 21 95 / 602 – 0
Fax +49 (0) 21 95 / 602 – 191
www.gira.de
info@gira.de
DOWNLOAD MANUALS:
GIRA 039601 Electronic Thermostat Operating Instructions
Free Money Online Casino No Deposit Canada However, and players have no control over it.…
Eureka Casino No Deposit Bonus Codes For Free Spins 2026 Furthermore, and beginner-friendly as well.…
Top 10 Online Canada Casinos Top 10 online canada casinos you can contact Easy Slots'…
2026 Canada Changes In Blackjack 2026 canada changes in blackjack an online casino reload bonus…
Mannheim Casino No Deposit Bonus Codes For Free Spins 2026 Don't miss out on this…
Slot Games For Real Money I should start with a variety of gambling options, you…