HT250S SET is a wireless room thermostat. The HT250S SET room thermostats are used in heating systems to keep the room temperature constant at the set temperature.
USAGE AREAS
Offices
The device can be used on combi boilers and on all on/off heating systems operating at 220V AC 7A current and voltage values.
MECHANICAL DESIGN
The device consists of 3 parts:
The battery cover is attached to the plastic case. After the wall bracket is mounted in the wanted area, the plastic body is attached to the wall bracket
OPERATING PRINCIPLES
HT250S SET room thermostat specifications:
The thermostat measures the room temperature with its temperature sensor. The desired temperature value is set by turning the button to the right or left. When the room temperature rises above the set temperature value, the room thermostat sends a shutdown command to the modem. Modem Turns off the relay by receiving the command. Digital display; The set temperature, battery life, room temperature and heating symbol are displayed. The heating symbol gives information about the operation status of the boiler. The product measures 0.1oC temperature accuracy. However, there is an operating sensitivity of 0.5oC to prevent the heating unit from starting and stopping too frequently. The device manages the heating systems by the on-off operation algorithm. This working algorithm is shown in the following graph.
Temperature Control
The room thermostat controls the room temperature according to the set value. The on / off temperature difference of the device is 0.5oC.
Calibration
The room thermostat can be calibrated if the measuring temperature wanted to be changed. The calibration range is -8oC to + 8oC.
When ordering, specify both the product type and the product code, for example the HT250S SET wireless room thermostat.
ROOM THERMOSTAT INSTALLATION
Remove the room thermostat by pulling it out of the wall bracket. If you want to use your room thermostat in a fixed place, mount the dismantled wall apparatus in a room you frequently use in your living space. If you want to use your room thermostat with the table bracket, place the room thermostat on the table bracket by removing the wall bracket. For example; Like your home lounge or living room. Avoid installing the room thermostat where there is a lot of air circulation, such as door entry or window edge. Also, do not place near heating units (heating panels, fireplaces etc.) and direct sunlight areas. We recommend that the room thermostat is placed at a height of 50 cm to 150 cm from the floor. You can try a few places to find where you can place the room thermostat
If the room thermostat is to be used with the wall bracket, the wall bracket must be mounted on a flat wall. Local electrical regulations must be observed during installation. Installation of room thermostat must be done by authorized personnel. The parts included in the room thermostat are made of ABS, PC materials. In systems with room thermostats, if there are thermostatic radiator valves, keep them in the open position.
Remove the battery cover located on the back of your room thermostat. Insert a 3V DC (2xAAA) alkaline battery into the battery compartment. When installing batteries, make sure they are incorrect position. Place the room thermostat in the wall bracket or table bracket by closing the battery cover. Replace both batteries at the same time.
WARNING!
Please dispose of your discharged batteries in waste bin which is separated for battery wastes.
MAINTENANCE
The device is maintenance-free.
MODEM
Green | The receiver synced with the thermostat and Works properly. |
Green Flashing | Pressed to receiver sync button and waited for the thermostat sync signal. |
Red | The receiver has energy but no thermostat synced. |
Red Flashing | The boiler shut down because of, no signal from the thermostat for more than 22 minutes. |
Orange | On Manual Mode. |
MODEM PLACEMENT
The important thing to note for receiver placement is that avoiding physical contact with the boiler and protecting against materials such as liquid, dust etc. You can place your receiver in the boiler’s cabinet without physical contact with the boiler or mount the receiver to Wall.
MODEM SETUP
WARNING!
Only persons who have got Professional Competence should make operations electric wiring or boiler setup.
APPLICATION EXAMPLE
SYSTEM COMBINATION
APPLICATION EXAMPLE
WARNING!
SYNC ROOM THERMOSTAT AND RECEIVER
ROOM THERMOSTAT HEATING CALIBRATION
If you want to take the temperature on your thermometers in your living space as a reference, you need to calibrate your room thermostat. For this:
Note: Recommended temperature calibration is “0.0oC”.
Room Thermostat
Power Supply | |
Operating Current | 3V DC (2 x AAA alkaline battery) |
Battery Life | 1 Years (2 x AAA) |
Operational Data | |
Temperature Measurement Accuracy | 0.1oC |
Operating Sensitivity | 0.5oC |
Operating Temperature Range | (5oC) – (30oC) |
Environmental Conditions | |
Operating Temperature | (0oC) – (+45oC) |
Storage Temperature | (-10oC) – (+50oC) |
Transport Temperature | (-10oC) – (+50oC) |
Standards | |
Radio and Telecommunications Terminal Equipment Regulation | 2014/53/EU (R&TTE/RED EN 301 489-1 V2.1.1:2017, EN 300 220-1 V3.1.1:2017, EN 301 489-3 V2.1.1:2017, EN 300 220-2 V3.1.1:2017, EN 62479: 2010, EN 60730-2-9:2010, EN 60730-1:2011) |
Electromagnetic Compatibility Regulation | 2014/30/EU (EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007 |
Low Voltage Directive | 2014/35/EU (LVD EN 60730-2-9:2010, EN 60730-1:2011) |
General Data | |
Weight (including package) | 435 g |
Color | White |
Material | ABS, PC |
Modem
Power Supply | |
Operation Current | 220V AC |
Relay NO Switching Current | 7A (220V AC) |
Environmental Conditions | |
Operating Temperature | (0oC) – (+45oC) |
Storage Temperature | (-10oC) – (+50oC) |
Transport Temperature | (-10oC) – (+50oC) |
General Data | |
Color | White |
Material | ABS |
DOWNLOAD MANual:
General life HT250S SET Wireless Room Thermostat Data Sheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…