NORA 270S is a wired room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economical heating/cooling.
NORA 270S AND EQUIPMENT
NORA 270S Room Thermostat
Dimensions | 85mm / 125mm / 19.2mm |
Operating Current | 3V DC (2 x AAA alkaline battery) |
Relay NO Switching Current | 2A (30VDC Resistive load) 0.5A (125VAC Resistive load) |
Temperature Measurement Accuracy | 0.1° C |
Operating Temperature Range | (5° C) – (30° C) |
Battery Life | 1 Years (2 x AAA) |
Operating Temperature | (-10° C) – (+50° C) |
Storage Temperature | (-20° C) – (+60° C) |
Buttons Functions
1 | Economy Mode |
2 | Temperature Adjustment (Increasing) |
3 | Comfort Mode |
4 | Heating/Cooling Modes |
5 | Temperature Adjustment (Decreasing) |
6 | ON/OFF and Setting Button |
1 | Room Temperature | |
2 | Set Temperature | |
3 | Economy Mode | |
4 | Comfort Mode | |
5 | Heating Indicator – If the Heating Indicator is blinking, the heating unit is working. – If the Heating Indicator is steady, the heating unit is not working. | |
6 | Cooling Indicator – If the Cooling Indicator is blinking, the cooling unit is working. – If the Cooling Indicator is steady, the cooling unit is not working. | |
7 | Battery Indicator |
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room which is used most frequently. For instance; the living room or lounge. Placing the Room Thermostat in a spot that has air circulation like the entrance of a room or the side of a window should be avoided. Also anywhere close to heating/cooling units such as radiator, stove, and spots that get direct sun lights would not be suitable. The room Thermostat needs to be located above the floor 150 cm in height. Few trials may be made to find the most convenient spot.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off.
As shown in the picture, press the screwdriver forward from the space shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back.
Low Battery Warning: When the “
Warning: When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries
ROOM THERMOSTAT WIRING DIAGRAM
Warning!
Operations within the heating / cooling unit or the electrical installation must be carried out by professionally qualified persons.
ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly sensitive. You may need to calibrate your Room Thermostat if you would like to get the same temperature values with other thermometers in your living space.
Note: Recommended tempreture calibration is “0.0 C”.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This operation resets the mode temperature values, calibration setting and heating/coling modes to factory setting. To reset your Room Thermostat to factory setting:
There are 2 modes in the Room Thermostat. These are Comfort Mode “
In order to change the comfort mode temperature value;
In order to change the economy mode temperature value;
You can use the “+” and “-” buttons to use the Room Thermostat manually.
TPI ROOM THERMOSTAT WORKING LOGIC
Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI technology predict when the temperature of your home will rise above or below the set temperature and turn the heating / cooling unit on and off accordingly. This ensures that your home stays at the temperature you set without maximum deviations up and down.
What is TPI?
TPI technology is designed to ensure that you get the best possible energy efficiency from your heating / cooling system. It measures and applies the best possible timings to deliver and maintain your home at the set temperature level.
How does TPI work?
Thanks to the advanced artificial intelligence technology found in the software, it adapts to the temperature change of the environment in which it is located. By creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how to maintain this temperature. In this way, it provides minimum energy consumption by calculating how long your heating / cooling unit should work for.
What is the difference?
In non-TPI room thermostats, the heating / cooling unit works and stops continuously until it exceeds the set temperature value. If the set temperature drops below a certain amount, the heating / cooling unit will work again. This creates greater temperature fluctuations and less energy control. TPI Room Thermostats, on the other hand, provide higher savings and comfort compared to On/Off room thermostats with the advantages it has.
Heating Mode
Your room thermostat takes the average room temperature of last 40 seconds as basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.
TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC
TEMPERATURE (ºC) – – – – Desired Temperature —- TPI Room Thermostat
Cooling Mode
Your room thermostat takes the average room temperature of last 40 seconds as basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.
TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC
TEMPERATURE (ºC) – – – – Desired Temperature —- TPI Room Thermostat
WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT
Is my Room Thermostat compatible with my heating/cooling unit?
If your heating / cooling unit has on-off connections, your Room Thermostat is compatible. You can find information about your heating / cooling unit from your heating / cooling unit operating manual or from your heating / cooling unit service.
How will I connect my Room Thermostat to the heating/cooling unit?
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş. which Head Office and production site is located on Fatih Mah. 1188 Sk. No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.
Additional Information: The mentioned product can be used with heating/cooling units with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.
Manufacturer
Product
Download manuals:
General life NORA 270S DIGITAL ROOM THERMOSTAT USER MANUAL
GENERAL NORA 270S Digital Room Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…