MITRA 110S is a wired room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economic heating
MITRA 110S AND EQUIPMENT
Dimensions ( H / L / W ) | 85mm / 125mm / 24mm |
Operating Current | 3V DC (2 x AAA alkaline battery) |
Relay NO Switching Current | 2A/30VDC (Resistive load) 0.5A/125VAC (Resistive load) |
Temperature Measurement Accuracy | 0.1oC |
Operating Sensivity | 0.5oC |
Operating Temperature Range | (5oC) – (35oC) |
Battery Life | 1 Year (2 x AAA) |
Operating Temperature | (-10oC) – (+50oC) |
Storage Temperature | (-20oC) – (+60oC) |
ROOM THERMOSTAT
Room Thermostat Indicator LED Descriptions
If it blinks once | The relay contact opens and the heating unit stops working. |
If it blinks twice | The relay contact closes and the heating unit starts. |
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room which is used most frequently.For instance; living room or lounge.Placing the Room Thermostat in a spot that have air circulation like entrance of a room or side of window should be avoided. Also anywhere close to heating units such as radiator, stove and spots which get direct sun lights would not be suitable. Room Thermostat needs to be located above the floor 150 cm height. Few trials may be made to find the most convenient spot.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off As shown in the picture above, press the screwdriver forward from the space shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back.
WARNING!
When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries
WARNING!
Operations inside the boiler or related to the electrical installation must be carried out by persons with professional competence.
ROOM THERMOSTAT WORKING LOGIC
Your Room Thermostat will start working from the moment you insert the batteries Your Room Thermostat measures the temperature of its environment every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you have set, your Room Thermostat will send a command to the Receiver and turn off the boiler , if it falls below 0.5 degrees, it turns on the boiler. Thus, it ensures that the ambient temperature remains within a certain range
Is my Room Thermostat compatible with my boiler?
If your boiler has on-off connections, your Room Thermostat is compatible. You can learn the information about your boiler from the boiler user manual or your boiler service.
How will I connect my boiler with my Room Thermostat?
We recommend that the connection between your Room Thermostat and your boiler should be made by professionally qualified persons. 2×0.75 mm cable is sufficient for the Room Thermostat – boiler connection.
Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of your boiler. Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Room Thermostat as shown in the “ROOM THERMOSTAT WIRING DIAGRAM” section. The direction of the cable ends does not matter.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.
Compatible Directives:
Additional Information: The mentioned product can be used with heating/cooling units with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval
Manufacturer
Product
DOWNLOAD MANUALS:
General life MITRA 110S DIGITAL ROOM THERMOSTAT User Manual
GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…