The Cync™ Smart Thermostat works with most central residential heating and cooling systems.
Heating: Up to 2 stages
Cooling: Up to 2 stages
Heat Pumps: Up to 4 heating stages and up to 2 cooling stages
Must be within range of 2.4GHz Wi-Fi to enable smart and out-of-home control.
Minimum iOS and Android requirements: Android 8 or higher and iOS 14 or higher.
Scan here to check your wiring compatibility before getting started.
For detailed step-by-step instructions tailored to your home’s wiring configuration,use the Sync App installation guide.
Power Up!
Your Cync Thermostat provides more features than a traditional thermostat including out-of-home, voice,* and app control. The Cync Thermostat requires constant power so that it is always ready to respond to your voice* or Cync App.
There are two ways to provide the necessary power:
What’s the Difference Between a C Wire and PEK?
C WIRE
The C wire delivers power from the HVAC control board to your thermostat.
POWER EXTENDER KIT (PEK)
The PEK provides power to the thermostat when there are not enough wires available to connect to the C wire/ C terminal on the thermostat. A PEK is included in the box.
Let’s Determine How to Power Your Cync Smart Thermostat
Remove your existing thermostat panel and look at the wires attached. If you don’t see screws on the face plate, it should just pull off. Look for a wire connected to the C terminal. Oftentimes, the wire is blue.
Your existing thermostat wiring may have an unused C wire tucked behind the wall. If a C wire is there, check to make sure the other end of the wire is connected to the C terminal on your HVAC control board.
Which Directions Do I Need to Follow for My Installation?
YES, I DO HAVE A C WIRE
Proceed to the next page.
NO, I DON’T HAVE A C WIRE
We’ve got you covered. It will take a few extra steps, including installing a PEK in your HVAC unit. Go to page 27 to get started.
Remove the Old Thermostat Panel
Remove your existing thermostat panel. If you don’t see screws on the faceplate, it should just pull off. Then, look at the wires attached.
If the old thermostat has 110/120V wires with wire nuts, it is a high-voltage system and not compatible with the Cync Thermostat.
Take a Picture of Your Existing Wiring
Take a picture of your existing wiring for reference.
Disconnect the wires and unscrew the old thermostat base. Be careful to keep the wires from falling back into the wall. Hold your Cync Thermostat in its new location. If the old screw holes or an unpainted area are visible, use the optional Trim Plate to cover them. If the Cync Thermostat doesn’t require the optional Trim Plate, skip to page 20.
Mark Location Without the Optional Trim Plate
OPTIONAL TRIM PLATE
Place Trim Plate against the wall with the Back Plate in front. Screw in both screws.
Press the terminal lever on the side of the Base Plate. Slide the wire into the terminal. The lever will stay depressed when the wire is properly inserted in the terminal.
Insert your labeled wires into the terminals:
Labeled Wire | Thermostat Terminal | ||
Insert | Y / Y1 | into | Y1 |
Insert | W / W1 | into | W1 |
Insert | G | into | G |
Insert | C | into | C |
Insert | Rc or Rh | into | Rc |
For heat pumps insert OB Labeled Wire into OB Thermostat Terminal.
Insert any remaining wires into the corresponding terminals on the Back Plate. Then push excess wires into the wall.
Turn the Power Back On
The PEK is required to power your Cync Thermostat when the C wire is not present. If you have any concerns handling wiring, hire a qualified HVAC technician.
BEFORE YOU DO ANYTHING! Turn Off the Power!
Power off your HVAC System.
Before doing anything, power off your system. Check for a master switch at your HVAC equipment. If there isn’t a master switch, please turn off the power at the circuit breaker box. After turning off the power, try adjusting the thermostat temperature to make sure the power is off.
Take a Picture of Your Existing Wiring
Take a picture of your existing wiring for reference.
Remove any jumper wires (wires that connect to two terminals), like Rh to Rc.
The PEK requires certain wires to be present to complete the installation
Required Wires: 3-Wire Installation |
Y or Y1 |
G |
R or Rh or Rc |
If you do not have the wires listed on page 30 or 31, then your wiring is not compatible with the Cync Thermostat.
Required Wires: 4-Wire Installation |
W or W1 |
Y or Y1 |
G |
R or Rh or Rc |
If you have additional wires like OB, W2, or Y2, label those wires. You’ll reinstall them later.
Take your PEK, wire labels, tools, and smartphone to your HVAC system.
Locate the Thermostat Wiring Inside Your HVAC System
TURN OFF POWER TO HVAC SYSTEM!
WARNING:
Label only the R, Y or Y1, G, and W or W1 wires with the matching labels provided. If you have more than one wire going into these terminals, only label those going to your thermostat.
NOTE: 3-wire installations will include only R, Y or Y1, and G wires.
NOTE: 3-wire installations will include only R, Y or Y1, and G wires.
Connect the labels on the PEK to the control board terminals.
PEKWire | Control Board Terminal | ||
Insert | R | into | R |
Insert | G | into | G |
Insert | Y | into | Y |
Insert | W | into | W |
Insert | C | into | C |
Connect the wires going to the thermostat to the PEK. Press button on top of PEK and then insert wire into the terminal.
Thermostat Wire | PEKTerminal | ||
Insert | Rc / Rh | into | R |
Insert | G | into | G |
Insert | Y / Y1 | into | Y |
Insert | W / W1 | into | W |
Check to make sure your PEK is wired between the HVAC control board and the wiring going to the thermostat. Once confirmed, mount the magnetic PEK to the side or back of the HVAC unit.
The PEK has a magnetic back. Stick to the side or back of your HVAC unit.
Close the HVAC cover panel making sure no wires are strained or pinched.
TIP: Make sure your HVAC panel is fully closed. Some systems may not turn on if the cover panel is not properly closed. Return to your thermostat.
Disconnect the Wires & Remove the Old Thermostat
Disconnect the wires and unscrew the old thermostat base. Be careful to keep the wires from falling back into the wall. Hold your Cync Thermostat in its new location. If the old screw holes or an unpainted area are visible, use the optional Trim Plate to cover them. If the Cync Thermostat doesn’t require the optional Trim Plate, skip to page 44.
Mark Location Without the Optional Trim Plate
Drill Holes & Attach the Back Plate
Press the terminal lever on the side of the Base Plate. Slide the wire into the terminal. The lever will stay depressed when the wire is properly inserted in the terminal.
Insert your labeled wires into the terminals:
4-Wire Labeled Wire | Thermostat Terminal | ||
Insert | Y / Y1 | into | PEK |
Insert | W / W1 | into | W1 |
Insert | G | into | C |
Insert | Rc / Rh | into | Rc |
3-Wire Labeled Wire | Thermostat Terminal | ||
Insert | Y / Y1 | into | PEK |
Insert | G | into | C |
Insert | Rc / Rh | into | Rc |
Insert any remaining wires into the corresponding terminals on the Back Plate. Then push excess wires into the wall.
Align the Cync Thermostat over the Back Plate. Orient so that the Thermostat control buttons are on the bottom. Gently push the thermostat into place until it clicks.
Turn the Power Back On
Begin setup in the Cync App within 30 minutes after powering on the thermostat. After 30 minutes, re-enable setup mode by removing the thermostat from the Back Plate and re-attaching it.
Congratulations!
You’ve completed the Cync Thermostat installation
Make sure your thermostat is in OFF Mode. To initiate manual setup, press and hold the – and + buttons together for 10 seconds. Use the – and + buttons to toggle to the desired configuration and lock in the selection by pressing and holding the – and + buttons together for 5 seconds or waiting 30 seconds for it to time out.
Setting the power wires incorrectly may cause damage to the HVAC equipment and/or thermostat.
FCC Compliance Statement and Compliance Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Canada IC Compliance Statement
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
Canada IC Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with 20cm between the radiator & your body.
Download Manual:
GE Cync Smart Thermostat En Route Installation Guide
GE-CYNC 93129894 Smart Programmable Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…