The radiator thermostat O81RF can conveniently regulate the single radiator according to the wireless commands received from the C801 weekly thermostat that can manage up to 8 radiator thermostat. The weekly thermostat C801 has an internal sensor that measures the temperature in the room/zone and cyclically transmits it to the radiator thermostats O81RF. Communication between weekly thermostat and radiator thermostats is bi-directional. This ensures that the information sent reaches the recipient.
KEYS
INFORMATION DISPLAYED DURING NORMAL OPERATION
SAFETY INSTRUCTIONS
Using this device for any purpose other than that described in this operating manual does not fall within the scope of intended use and shall invalidate any warranty or liability. This also applies to any conversion or modifi cation work. This device is intended for private use only. The device may only be operated indoors and must be protected from the effects of damp and dust, as well as solar or heat
radiation
Do not dispose of the device with regular domestic waste! Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive. Used batteries should not be disposed of with regular domestic waste! Instead, take them to your local battery disposal point
INSERTING (REPLACING) BATTERIES
Important notice: Never recharge alkaline batteries. Doing so will present a risk of explosion. Do not throw the batteries into a fi re. Do not short-circuit batteries
MOUNTING ON A RADIATOR
The O81RF radiator thermostat is easy to install, and can be done without draining heating water or intervening in the heating system. No special tools are required, nor does the heating have to be switched off. The union nut attached to the radiator thermostat can be used universally and without accessories for all valves with a thread size of M30 x 1.5. By means of the adapters in the delivery, the device can be installed on radiator valves of type Danfoss RA, RAV and RAVL series.
ADAPTERS FOR DANFOSS
Important notice: When installing, please ensure that the spigots inside the adapter (D) are in the same position as the indentations (E) on the valve. Latch the adapter, which corresponds to the valve, completely onto the valve body
SUPPORT RING
The valves from different manufacturers may have tolerance fluctuations that make the MAX! The radiator Thermostat is more loosely seated on the valve. The stability and seating of the valve can be improved using the provided support ring. Place the support ring (G) into the flange or onto the valve connection on the radiator and screw on the thermostat valve. If the support ring cannot be fitted, there is adequate stability and it is not needed for installation.
ADAPTER RUN
Note: Teach-in mode can be activated even whilst “InS” is still displayed.
TEACHING-IN OF C801 PROGRAMMABLE THERMOSTAT
The O81RF radiator thermostat must work with a C801 weekly thermostat; for this reason, each radiator thermostat will be taught-in to the weekly thermostat directly. These then take over the settings of the weekly thermostat (e.g. mode, temperature, week program). To teach in, proceed as follows:
Notes: As soon as the radiator thermostat has been taught in to weekly Thermostat, all data such as date, time or week program are transmitted to it via radio connection. The O81RF radiator thermostat can only be taught-in on one C801 weekly thermostat.
RESTORE THE FACTORY SETUP (rES)
The O81RF radiator thermostat can be reset to the initial state manually. Restoring the initial state deletes all settings and information about taught-in devices. To restore the initial setup, proceed as follows:
AUTOMATIC/MANUAL SETTING
Note: If the operating mode or the temperature on one O81RF radiator thermostat in the room/zone is changed, the change will be adopted by all devices associates.
SET “BOOST” OPERATING (BOOST)
Notes: The parameters of the “BOOST” function can setting only in the by the C801 weekly thermostat. If a long “Boost period” and a large valve opening have been set the radiator can get very hot. After changing the factory setting check that the radiator is not heated excessively. If the duration of the “Boost function” is set so that 999 seconds are exceeded the display will show the duration in minutes.
COMFORT ED ECONOMY TEMPERATURE
The comfort/economy temperature button (
Note: If the operating mode on one O81RF radiator thermostat in the room/zone is changed, the change will be adopted by all devices associates.
CHILD-PROOF LOCK / OPERATING LOCK (Loc)
DECLARATION OF CONFORMITY
Fantini Cosmi S.p.A. declares that the “O81RF Wireless Radiator Thermostat” device conforms to the 1995/5/CE R&TTE Directive and rules EN60730-1 e 2nd part. The full EC Declaration is available for download from “www.fantinicosmi.it” website
FANTINI
DOWNLOAD MANUALS:
Fantini cosmi O81RF Radiator Wireless Thermostat INSTRUCTION MANUAL
OTHER MANUALS:
Fantini cosmi O81RF Radiator Wireless Thermostat Technical Data Sheet
Fantini cosmi O81RF Radiator Wireless Thermostat INSTRUCTION MANUAL
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…