INSERTING OR REPLACING THE BATTERIES
To access the battery compartment, use your finger to prise off the cover, as shown in the figure. Insert two AA 1,5V alkaline long-life batteries, respecting the polarity indicated.
Warning: use alkaline batteries only. Do not use any type of rechargeable battery.
PROGRAMMING MENU
Use the MENU key to access the programming menu. Navigate through the eleven options with the aid of the wheel selector. The options are described below
SETTING THE CLOCK/CALENDAR
When the batteries are first inserted, O62C automatically calls up the predefined clock/calendar settings menu (2010 factory programming).
The programmable thermostat is installed on all the valves with thermostatic option of the H series, with connection M30x1,5 as shown below:
The programmable thermostat must be in “INST” or “ON” mode in order to fix it to the ring nut without too much effort. If the programmable thermostat is installed at a later time, select the “INST” menu before fixing it to the ring nut. To ensure better temperature adjustment, you are advised to install the programmable thermostat with the display facing upwards. IMPORTANT: if you hold onto the programmable thermostat when screwing the ring nut onto – or unscrewing it from – the valve, this will cause irreversible damage to the mechanism and the coupling teeth of the ring nut itself
REMOVING THE PROGRAMMABLE THERMOSTAT
Set the maximum temperature via the wheel selector (the display will show “ON”) and wait at least one minute. Press in the point indicated by the arrow (A) to release the programmable thermostat from the ring nut.
VALVE ADAPTATION PROCEDURE
At the initial start-up, press the OK key several times (skipping the clock/calendar setting operation) until the word ADAP appears on the display. O62C performs a self-calibration, checking the valve limit switches. This procedure may take a few minutes, after which O62C resumes normal operation. An additional adaptation procedure may be needed if the radiator does not fully cool down when the programmable thermostat is OFF. If the procedure concludes with error E2, check the correct coupling with the valve and take the batteries out for a few minutes, then replace them and perform a new valve adaptation procedure.
MANU (MANUAL) MODE
SETTING A PROGRAM
Up to 4 COMFORT (Tmax) switchovers and 4 ECONOMY (TMIN) switchovers can be defined for each of the seven days of the week, or for 3 groups of several days. DAY1 (Monday) – DAY2 (Tuesday) – DAY3 (Wednesday) – DAY4 (Thursday) – DAY5 (Friday) – DAY6 (Saturday) DAY7 (Sunday) refer to the days of the week shown beneath the times bar: Mo-Tu-We-Th-Fr-Sa-Su.
SETTING THE COMFORT/ECONOMY TEMPERATURE
JOLLY FUNCTION
SETTING THE OFFSET
Elements like shelves and curtains near a radiator can impede good heat diffusion, affecting the room temperature detected by the programmable thermostat and its subsequent adjustment. If the room temperature is very different from the temperature set on the programmable thermostat, you can insert an OFFSET correction factor:
Example: if the COMFORT temperature set on the programmable thermostat is 21 °C but the real temperature in the room is only 19 °C, enter a correction factor of +2,0 °C.
WINDOW FUNCTION
When the window is opened and the temperature therefore drops suddenly, O62C temporarily closes the valve (for a set time) to save energy. During this time, the ANTI-FREEZE symbol will be shown on the display
In the event of a prolonged absence, you can set the temperature for that period (or even the closure of the valve), along with the date and time of your return:
The set temperature or the chosen valve status (OFF-closed, ON-open) will appear on the display, together with the holiday symbol . Regardless of the operating mode defined by the current profile, the programmable thermostat adopts the new mode setting.
CHILDREN SAFETY FUNCTION
HEATING SHUT-OFF (VALVE CLOSURE
If necessary, you can close the valve to deactivate the heating in a room:
RIPRISTINO CONFIGURAZIONE DI FABBRICA
ANTI-FREEZE FUNCTION
If the room temperature falls below 6 °C, the programmable thermostat opens the valve until the temperature rises to 8 °C. This prevents the water in the pipes from freezing
ANTI-CALCIFICATION FUNCTION
Once a week (on Friday), O62C performs a valve opening/closing cycle to prevent the valve from calcifying.
DISPLAY SWITCH-OFF
GMT-DAYLIGHT SAVING TIME SWITCHOVER
PROGRAMMING VIA KEY O63P
O62C can be directly programmed via the programmer O63P, ensuring quick and easy programmable thermostat configuration thanks to the exchange of data via the Mini- USB connector. Using the key O63P and viewing the graphic interface on the PC, you can easily programme the daily time bands for the COMFORT (Tmax) and ECONOMY (Tmin) temperatures of the programmable thermostat. Once the temperature profiles of the various rooms have been stored on the key O63P, they can be uploaded onto the programmable thermostat O62C which thus automatically acquires the current time and date. This means that any pre-setting by the user is super% uous. For the programming, refer to the instructions enclosed with the programmer O63P. The device’s “Mini-USB” connector is only compatible with the cable of the programmer O63P; do not connect any other devices fitted with a Mini-USB port, as this could irreversibly damage the programmable thermostat.
FANTINI
DOWNLOAD MANUALS:
Fantini cosmi O62C Electronic Radiators Programmable Thermostat INSTRUCTION MANUAL
OTHER MANUALS:
Fantini cosmi O62C Electronic Radiators Programmable Thermostat Technical Data Sheet
Fantini cosmi O62C Electronic Radiators Programmable Thermostat INSTRUCTION MANUAL
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…