The CH193 chronothermostat must be installed in a 3-module recessed box, in the middle of the apartment, preferably 1.5 m off the ground.
PERFORM THE FOLLOWING OPERATIONS:
N.B. When CH193 is disconnected, the boiler contact remains in its current position.
Unscrew the lid to connect the auxiliary probe.
Use compatible Fantini Cosmi probes:
During black-outs, the programmed parameters will not be lost as the settings are stored in a non-volatile memory. Even when there are long power failures, the time/ date remain stored thanks to an internal battery.
KEYBOARD BLOCK
To make sure you don’t change any settings on the chronothermostat unintentionally while cleaning, enable the keyboard block by pressing the middle of the display for 5 seconds. The text “BLOCKED” appears on the display when the keyboard has been blocked. The keys will re-enable automatically after 30 seconds.
The chronothermostat is equipped with 6 keys, the function of which varies depending on the situation. It is described by the symbol which appears on the display next to the key.
SETTING TIME AND DATE
After the device switches on, press the key PROG briefly: the text “Setup” is displayed; now press
OPERATING PROGRAMS
The CH193 chronothermostat has different operating modes, called programs:
“AUTO” WEEKLY PROGRAM:
one of the four programmable temperatures can be associated to each half hour for each day of the week. This is the program displayed when the chronothermostat is switched on and is generally the one most used.
HOLIDAY” DAILY PROGRAM:
Like in the AUTO program, you may select one of the 4 programmable temperatures for each half hour, but the identical sequence will be repeated every day.
JOLLY” TEMPORARY PROGRAM:
you may choose to hold a certain temperature for a certain number of hours, after which it will go back to the previously active program.
“MAN” MANUAL PROGRAM:
the chronothermostat maintains a fixed temperature, for an unlimited amount of time until another program is selected.
SYSTEM OFF OR WITH ANTIFREEZE PROGRAM “OFF/ANTIFREEZE”:
the system remains off or else maintains a very low temperature (from 2 to 7°C) to prevent the fluid in the heating system from freezing.
Four different temperatures can be set and one can be selected for each half hour of the day in the AUTO and HOLIDAY programs. Three of these temperatures (T1, T2 and T3) can have values from 2° to 40°C, while the fourth, T antifreeze (TA), can range from 2° to 7°C, or be set at “OFF” (system off). The manual program has its specific temperature (TMan), like the JOLLY program (Tj), which are set in the respective screens and can range from 2° to 40°C. The ANTIFREEZE/OFF program, on the other hand, follows the temperature TA which, as we have said, can range from 2° to 7°C; or else, it can be set at “OFF”, switching the plant completely off
PROGRAM SELECTION
press SEL to select, in cyclical sequence, the different operating programs: AUTO -> MAN -> OFF -> HOLIDAY.
PLEASE NOTE: the JOLLY temporary program is not included in the program sequence, but can be selected directly by pressing the JOLLY key.
SETTING THE TEMPERATURES
press TEMP in the AUTO, HOLIDAY and OFF programs to change the value of the 4 programmable temperatures: when you press TEMP several times, the values T1, T2, T3, Ta appear in sequence; stop at the T you want to change and use the arrow keys
EDITING CURRENT DATE AND TIME
Press PROG briefly to enter the “SETUP” menu. Using
CUSTOMISATION OF WEEKLY “AUTO” PROGRAMMING AND DAILY “HOLIDAY” PROGRAMMING
Keep the key PROG pressed until the text “Config” is displayed. This menu allows you to program the weekly profiles (AUTO program) and daily profiles (HOLIDAY program) and to set the advanced functions (see the following paragraphs for their description).
PLEASE NOTE: if the text “Setup” appears instead of “Config”, you did not press the key long enough and you must press ENTER to go back to the normal operating condition and try again. When you enter the “Config” menu, a page appears which allows you to choose the desired temperature (T1/T2/T3/Ta) for each half hour of the indicated day (from 1 to 7 indicating the days from Monday to Sunday).
PLEASE NOTE: T1/T2/T3/Ta are displayed on the right of the screen with the symbols
N.B.: press
“JOLLY” PROGRAM SETTING
“OFF/ANTIFREEZE” PROGRAM SETTING
ALTERNATIVE DISPLAYS
Other information can be viewed in the AUTO and HOLIDAY programs in place of the temperature profile, by pressing the key DISP several times. The first time it is pressed the programmed temperature for the current halfhour appears, the second time it displays the date, the third time it displays the temperature of the external probe and the fourth time it goes back to the initial temperature profile.
AVAILABLE PROGRAMS
CH193 has several operating modes (programs):
“AUTO” WEEKLY PROGRAM
4 temperature levels can be used in the AUTO operating mode (Ta, T1, T2, T3), according to a programming with 30 minute steps, 24 hours a day, 7 days a week. The days are numbered from 1 to 7 and correspond to the seven days of the week, starting from Monday. To simplify programming, you may set the first day and copy it on the following days.
The default for days 1 – 5 (Monday to Friday) is:
while the default for days 6 and 7 (Saturday and Sunday) is:
The value of the 4 temperatures can be programmed using the TEMP function. The temperature profile (hourly variation) can be programmed using the PROG function.
“HOLIDAY” DAILY PROGRAM
4 temperature levels can be used in HOLIDAY operating mode, according to a programming with 30 minute steps, 24 hours a day. This achieves a daily programming, regardless of the days of the week. The default temperature profile is:
The value of the temperatures can be programmed using the TEMP function. The temperature profile (hourly variation) can be programmed using the PROG function.
JOLLY
The JOLLY mode allows you to set a programmable temperature (Tj) for a programmable number of hours (from 1 to 240). It is used when you wish to introduce a temporary variation to programming without changing the parameters, for example to maintain a high temperature for longer when spending an evening with friends or to keep it low when no one is home the weekend. If you enter JOLLY mode using the specific function key, when time is up it goes back automatically to programming in progress.
MANUAL
OFF
settable TEMPERATURES
The system can use 4 different temperature levels, three for normal use and one, called “antifreeze”, to be used when you wish to keep the boiler off, but without risking having the fluid in the system freeze.
Programming of the three T is conditioned by reciprocal values:
USING THE SEL KEY
The SEL key allows you to select the operating mode of the chronothermostat, according to the following programs:
To change the selected program, press SEL in sequence (cyclical). The first 3 statuses are signalled with a small text on the left of the display, while the OFF status appears in the graphical area at the top.
In AUTO, HOLIDAY and OFF
In JOLLY
USING THE PROG KEY
PROG (brief) -> SETUP
Winter/PAG1/Set
using
Hours HH: MM/PAG2/SEt
pressing
Min. HH:MM /PAG3/SEt
pressing
Year: YYYY/PAG4/SEt
pressing increases
Month: MM/PAG5/SEt
pressing cyclically increases
Date: DD/PAG6/SEt
pressing cyclically increases
PLEASE NOTE: when the date is set, the chronothermostat automatically determines the day of the week.
Summer Time YES/PAG7/SEt
Automatically selects summer time, applicable in Europe and some of the countries. This set up automatically updates the time when it changes (March and October). Use
PROG (long) -> CONFIG.
N.B.: press
Correction/PG01/XX.X°
Celsius/PG02/XX.X°
Light ON Xs/PG03
Int. Light X/PG04
Allows you to modify the luminous intensity of the display, at 10 levels. Press
Italiano/PG05
Allows you to change the language used during programming. Press
Block? NO(YES)/PG06
Reset? NO (YES)/PG07
CH193 vX.Y/–/PG08
EXT IN: —/PG12
Connecting a probe- EC18 – EC19 – EC20 allows you to set:
This function deactivates the system when the temperature read by the external probe is lower than the set temperature.
Connecting a voltage-free contact allows you to set:
Having selected ALR C or ALR 0, pressing
BEEP ON (OFF)/PG14
enables or disables the beep upon pressing a key. The selection is made by pressing
LED ON (OFF)/PG15
enables or disables switch on of the front LED (1 flash every 10 seconds). The selection is made by pressing
TOUCH TEST/PG16
This function is used by technical support. Exit by pressing
TOUCH SENS. (MED)/PG18
This function indicates the level of touch sensitivity. The user can choose between 3 levels (HI-MED-LO) by pressing the and keys. Press to go back to the hourly programming menu.
The DISP key allows you to view windows with different information regardless of the operating status, only when in AUTO or HOLIDAY modes.
The following windows may be viewed:
The following window is displayed:
Duration of JOLLY status (HH h MM m) / hour: min / Tamb
Using the arrow keys allows you to change the duration of the JOLLY status with hourly steps. The Jolly temperature is set by pressing the key TEMP, which displays a window such as the following:
Tj=xx.x° / hour:min / Tamb
Modify the temperature by using the arrow keys and. Pressing allows you to go back to view the “JOLLY status duration”. To exit JOLLY status before time is up, change the number of hours to zero using the arrow key , or else press SEL to go to the desired status (AUTO, MAN, HOLIDAY, OFF).
USING THE OFF-KEY
The OFF key allows you to switch the system off, in whatever operating status it is found
OFF / hour: min / Tamb
The antifreeze temperature (Ta) can be programmed by pressing TEMP, from OFF
WASTE DISPOSAL
The symbol of the crossed-out wheeled bin indicates that the products must be collected and disposed of separately from household waste. The batteries and integrated accumulators may be disposed of together with the product. They will be separated at the recycling facilities. A black bar indicates that the product was placed on the market after August 13th, 2005. Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human health. For more detailed information on the collection and recycling programmes available in your country, contact the local authorities or the sales point where you purchased the product.
(boiler always off) to an interval between 2.0 and 7.0°C, using the arrow keys
The following window is displayed:
FANTINI COSMI S.p.A.
DOWNLOAD MANUALS:
Fantini cosmi CH193 WEEKLY PROGRAMMABLE THERMOSTAT Instruction Manual
OTHER MANUALS:
Fantini cosmi CH193 WEEKLY PROGRAMMABLE THERMOSTAT Technical Data Sheet
Fantini cosmi CH193 WEEKLY PROGRAMMABLE THERMOSTAT Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…