Electronic programmable thermostat with a microprocessor, with weekly programming, to control heating and air-conditioning installations. The “radio system” provides a programmable thermostat CH150RF, one or few actuators (receivers) for temperature control, and an actuator for humidity control (optional).
Programmable thermostat transmitter
Receiver – actuator with 1 output relay
TEMPERATURE CONTROL OF A HEATING AND COOLING SYSTEM
TEMPERATURE CONTROL + HUMIDIFICATION
HOMOLOGATION AND STANDARDS
In conformity with EN 60730-2-9; EN 60730-2-11 standards. ErP classification: ErP Class IV; 2% (EU Reg. 811/2013 – 813/2013)
Wall mounting by means of the fastening base in round boxes 502-503. Two-wire connection with the user. Install the programmable thermostat at 1,5 m height from the floor, away from kitchens, heat sources, windows, and doors.
The programmable thermostat has:
VISUALIZATION
MANUAL
The programmable thermostat regulates the room temperature using the set temperature within 24 hours.
T1:The temperature can be set from 2 to 40°C
AUTOMATIC
The programmable thermostat regulates the set temperatures according to the schedules on the weekly profile. It has 2 winter programs and 1 summer program (prescribed).
In automatic mode can be set three temperature levels T1-T2-T3.
Note
T3 cannot be less than T2 and T2 cannot be less than T1.
HOLIDAY
JOLLY
OFF (turned OFF)
This mode is used to manage system operation for maintaining the antifreeze temperature, set from 2 to 7°C. Complete turn OFF of the system T1=OFF.
Example: Automatic Mode – Jolly for 1 week – the programmable thermostat completes the period of Jolly and resumes the automatic mode.
T1: The temperature is set manually from 2 to 40°C.
These functions are selected by accessing the technical menu of the programmable thermostat.
TEMPERATURE
REGULATION TYPE
When it is required to heat “ON” the boiler or the cooling system stops functioning only when it reached the set temperature value (set point) within the differential. It is reached quickly the set-point in installations with low inertia; on the contrary, in systems with high inertia are possible high-temperature oscillations.
This regulation type allows you to limit the thermal differential to the minimum, significantly increasing comfort. In proportional regulation, the “heat request“ periods are managed within the proportional band.
A range means the value at which the programmable thermostat starts regulation with ON and OFF cycles (installation) as a function of the prescribed period. Range regulation from 1 to 4°C by 0.1°C increments.
ON-OFF CYCLES
Are defined according to the programmable thermostat’s reached temperature, if the ambient temperature is equal to the set-point and the cycles are 50% ON and 50% OFF (proportional contribution +/- one percentage of the integral part contribution).
The regulation period is set in 5/10/20 minutes, with value managed for ON-OFF cycles.
EXAMPLE
Period of 10 minutes 70% ON = 7 minutes, 30% OFF = 3 minutes. The period and the range should be defined according to the inertia and to the heat transfer type, such as:
It has the advantage of decreasing the temperature excess regarding ON-OFF regulation, only achieving the set-point will need more time.
SYSTEMS BEHAVIOR DURING ON-OFF AND PROPORTIONATE REGULATION
HI high
LO low
Possibility to configure temperature probes of four types.
PROGRAMMABLE THERMOSTAT’S TEMPERATURE PROBE
Floor probe (for heating with radiant panels)
It controls the temperature in the room where is installed the programmable thermostat. The floor sensor is used for control and as a limit probe for extra temperatures of radiant panels’ fluid. Reaching the limit temperature, the programmable thermostat stops functioning regardless of set-point achievement. The limit is set in the range of 15 ÷ 45 °C.
INTERNAL TEMPERATURE PROBE (AMBIENT)
Adjusts the ambient temperature read by the second probe.
This mode can be used to manage better the domestic environment, in the case when the programmable thermostat is placed in an unfavorable position.
EXTERNAL PROBE
Displays the room temperature by touching any button on the programmable thermostat’s front.
Note
The external temperature is not adjusted.
In cases, when the programmable thermostat position is not favorable for an optimum regulation of the environment, and you do not want to appeal to the ambient secondary probes, is possible to correct the temperature, read by the programmable thermostat. Correction range from -4°C to +4°C with increments of 0,1°C.
The device calculates the system’s advance switching-on time needed to achieve the desired temperature at the set time of the day, taking into consideration its thermal inertia. The optimization takes place only at the first system’s switching-on of the day.
The unit turns the system on for 1 minute per day (h 23.58), thereby operating the water circulation pump and preventing it from blocking. This takes place only if the system has never been turned on during the day.
Separate probe
2-wire connection
Telecomfort CT3MA – GSM phone activator
CH150RF is designed to be connected to the mobile line GSM phone activator Telecomfort CT3MA. Telecomfort CT3MA allows a programmable thermostat’s remote control via SMS messages or APP Intelliclima+. It also allows the remote verification of the ambient temperature and the correct functioning of the programmable thermostat.
DOWNLOAD MANUALS:
Fantini cosmi CH150RF Weekly Programmable Thermostat Technical Data Sheet
Fantini Cosmi CH150RF Weekly Programmable Thermostat Technical Data Sheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…