Electronic programmable thermostat with a microprocessor, with weekly programming, to control heating and air-conditioning installations.
Programmable thermostat transmitter
TEMPERATURE CONTROL OF A HEATING AND COOLING SYSTEM
ELECTRICAL FEATURES
ACTUATOR CH171D
HOMOLOGATION AND STANDARDS
The programmable thermostat has:
VISUALIZATION
MANUAL
The programmable thermostat regulates the room temperature using the set temperature within 24 hours.
AUTOMATIC
The programmable thermostat regulates the set temperatures according to the schedules on weekly profile. It has 2 winter programs and 1 summer program (prescribed). In automatic mode can be set three temperature levels T1-T2-T3.
Note: T3 cannot be less than T2 and T2 cannot be less than T1.
HOLIDAY
JOLLY
The programmable thermostat controls the installation using a set temperature over a period of time ranging from 1 hour to 99 days and 23 hours. At the end of the set time, the programmable thermostat returns to the previously used operation mode. This function can be excluded at any time by setting a different operation mode.
OFF (turned OFF)
This mode is used to manage system operation for maintaining the antifreeze temperature, set from 2 to 7°C. Complete turn OFF of the system T1=OFF.
TEMPERATURE
When it is required heating “ON” the boiler or the cooling system stops the functioning only when is reached the set temperature value (set point) within the differential. It is reached quickly the set-point in installations with low inertia; on the contrary, in systems with high inertia are possible high temperature oscillations.
This regulation type allows you to limit the thermal differential to the minimum, significantly increasing the comfort. In proportional regulation the “heat request“ periods are managed within the proportional band.
A range means the value at which the programmable thermostat starts regulation with ON and OFF cycles (installation) as a function of the prescribed period. Range regulation from 1 to 4°C by 0.1°C increments.
ON-OFF CYCLES
Are defined according to the programmable thermostat’s reached temperature, if the ambient temperature is equal to the set-point and the cycles are 50% ON and 50% OFF (proportional contribution +/- one percentage of the integral part contribution).
Regulation period is set in 5/10/20 minutes, value managed for ON-OFF cycles.
SYSTEMS BEHAVIOR DURING ON-OFF AND PROPORTIONAL REGULATION
Possibility to configure temperature probes of four types.
PROGRAMMABLE THERMOSTAT’S TEMPERATURE PROBE
It controls the temperature in the room where is installed the programmable thermostat. The floor sensor is used for control and as a limit probe for extra-temperatures of radiant panels’ fluid. Reaching the limit temperature, the programmable thermostat stops the functioning regardless of set-point achievement. The limit is set in the range 15 ÷ 45 °C.
Adjusts the ambient temperature read by the second probe. This mode can be used to manage better the domestic environment, in case when the programmable thermostat is placed in unfavourable position.
Displays the room temperature by touching any button on the programmable thermostat’s front.
Note: the external temperature is not adjusted.
In cases, when the programmable thermostat position is not favourable for an optimum regulation of the environment, and you do not want to appeal to the ambient secondary probes, is possible to correct the temperature, read by the programmable thermostat. Correction range from -4°C to +4°C with increments of 0,1°C.
PUMP ANTI-SEIZURE FUNCTION
The unit turns the system on for 1 minute per day (h 23.58), thereby operating the water circulation pump and preventing it from blocking. This takes place only if the system has never been turned on during the day.
The device calculates system’s advance switching-on time needed to achieve the desired temperature at the set time of the day, taking into consideration its thermal inertia. The optimization takes place only at the first system’s switching-on of the day
The unit turns the system on for 1 minute per day (h 23.58), thereby operating the water circulation pump and preventing it from blocking. This takes place only if the system has never been turned on during the day.
DOWNLOAD MANUALS:
Fantini Cosmi CH150R Weekly Programmable Thermostat Technical Data Sheet
Fantini Cosmi CH150R Weekly Programmable Thermostat Technical Data Sheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…