Dear customer, thank you for purchasing the Fantini Cosmi digital room thermostat, model C820RQ, for the temperature management and home comfort. This manual contains all the information required for a correct installation and configuration. You can also download this manual in digital format and in several languages by framing the QR code below and entering the product code
Package contents
Warnings
For an optimal operation of the appliance, it is recommended that the thermostat be installed at a height of approx. 1.5 mt above the floor, in a suitable position to correctly detect the room temperature (see example in the drawing
WALL MOUNTING The tabs on the back of the base must be removed for the wall mounting. In this way the thermostat will fit tightly against the wall.
ON FLUSH MOUNTING BOXES
The thermostat is supplied with a square and rectangular base to allow the installation on a flush-mounting box type 500-502-503.
By unscrewing the screw and lowering the plastic cover, as shown in the drawing, you will have access to the electrical connections.
Connect terminals 1 and 4 to the system.
230V 50Hz
Connect terminals L-N to the 230V power supply
BATTERIES
To power the device with batteries, use 2 AA 1.5V alkaline batteries. Insert the batteries in the battery compartment at the rear of the device, observing the indicated polarities
Notes:
LOW BATTERY WARNING
DISPLAY ACTIVATION AND ROOM TEMPERATURE DISPLAY
When the thermostat is in Stand-by mode, the display is off. Slightly pressing the central MODE button for 1 second, the screen activates and displays the room temperature. If the system is switched off, OFF will be displayed
OPERATING MODE
CHANGING THE DESIRED TEMPERATURE
By pressing the UP or DOWN arrows, the desired temperature value (Set Point) of the current operating mode can be changed. The value is increased or decreased in steps of 0.1°C.
CHANGING THE BASIC SETTINGS (USER MENU)
To change several basic settings and optimise the display use, you can access the User Menu:
Password
In order to prevent other users from changing the thermostat settings, a password can be entered to lock the buttons. To enable this function, choose an access code with a value from 1 to 999. This code must be entered, followed by the MODE button, to access any thermostat setting from the temperature control to basic or advanced parameters.
To disable the key lock, set the value to “0”.
Stand-by
You can change the Stand-by activation time.
Display light intensity
To improve the visibility of the LEDs in the room or to soften their light intensity level, the default value can be changed.
Temperature correction
If the thermostat is close to heat sources or cold current areas, it is possible to correct the measured temperature value.
Season
Change the season to activate the control in heating or cooling mode. When the system is switched on during the winter season, the central LED flashes red , while it flashes blue when the system is switched on during the summer season.
Firmware
On this screen you can see the firmware release version
To change other thermostat settings, you can access the Advanced Functions menu:
SET POINT LIMITS
The desired temperature range can be limited by the user (Set Point).
Antifreeze function
This function avoids system blockage due to possible pipe freezing during the winter period.
Data displayed on the Home page
ON/OFF
During the ON/OFF adjustment the thermostat switches on (ON) when the measured room temperature is below/above the desired temperature value (Set Point), and switches off (OFF) when the desired temperature is reached. In this adjustment mode, the Optimisation function (P08) can be activated and the Static Differential value (P09) can be set
TPI
If the thermostat is powered by a 230V power supply, it is possible to take advantage of the special TPI algorithm which, by taking into account parameters such as the room temperature, the energy class of the flat (P12), the type of emission terminal (P13), the proportional band (P15) and the control period (P14), optimises the system runtimes for a more constant comfort level, ensuring optimal energy savings.
Optimisation
When the thermostat is set to the ON/OFF adjustment, this function allows to minimise the energy consumption of the heating/cooling system by adjusting its on/off times according to the installed type of system and the set differential
Static differential
By selecting the ON/OFF adjustment, it is possible to set the value of the static differential to manage the temperature difference between the OFF and ON modes.
The Pump Anti-seizure function avoids limestone deposits during the system shut- downs, resulting in short activation times of the pump after 24 consecutive hours of inactivity. The function is optional and can be enabled by configuring the activation minutes of the circulating pump. Once enabled, this function remains active even when the thermostat is in OFF mode.
Virtual relay
By enabling the virtual relay function, it is possible to display the activity status of the system even when the display is switched off (Stand-by). When the system is switched on during the winter season, the central LED flashes red , while it flashes blue when the system is switched on during the summer season.
Energy class
When the TPI adjustment is active, it is necessary to set the energy class of the building for enabling the optimisation of the system’s runtimes.
Type of emission terminals
If the TPI adjustment is activated, it is necessary to also set other related parameters. The emission terminal identifies the final element of the heating/cooling system. By setting the emission terminal, the values of the Proportional Band and the Adjustment Period are automatically set (see the below table); however, they can still be changed.
TPI Adjustment Period
The TPI Adjustment Period indicates the duration of a systemon+off cycle. This period depends on the type of the emission terminal. The values for the Adjustment Period are set automatically by setting the emission terminal (see table P13); however, they can still be changed
TPI proportional band
The Proportional Band is the temperature range around the Set Point at which TPI adjustment is active. Beyond this range, adjustment is of the ON/OFF type. The values of the proportional band are set automatically by setting the emission terminal (see table P13); however, they can still be changed.
Thermostat reset
After enabling the reset, the thermostat settings are restored to the default values.
Symbol of the crossed-out wheeled bin indicates that the product must be collected and disposed of separately from household waste. Batteries and the integrated accumulators may be disposed of together with the product. They will be separated at the recycling facilities. A black bar indicates that the product was placed on the market after August 13th, 2005. Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human health. For more detailed information on the collection and recycling programs available in your country, contact the local authorities or the sales point where you purchased the product.
GENERAL WARRANTY CONDITIONS
The conventional warranty lasts 24 months, starting from the date the equipment is installed. The warranty covers all parts of the equipment, except those subject to normal wear and tear resulting from use
FANTINI
SUPPORTO TECNICO
EXPORT DEPARTMENT
DOWNLOAD MANUALS:
Fantini cosmi C820RQ ROOM THERMOSTAT Instruction Manual
OTHER MANUALS:
Fantini cosmi C820RQ ROOM THERMOSTAT Product Data Sheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…