Display and Button Functions
Quick Command Guide
N. B Please note, when first powered or in the event of a power loss the time will be flashing and the time and date will need to be set. Follow steps 2 – 6 to set the time on first setup. Changes between summer and winter time are handled automatically by the unit.
Operation Modes:
AUTO
Temporary manual override of set temperature. In Auto mode, the user can turn the dial to adjust the set temperature as below:-
Temporary set temperature range: 5oC – 35oC. Default: 21oC
N.B: The temporary set temperature will not replace the original program event’s set temperature. When the program event ends, it will return to the default heating program automatically.
MAN
Permanent manual override of set temperature.
Permanent set temperature range: 5oC – 35oC. Default: 21oC
OFF
Turn the heating off permanently.
All Day Mode (AL)
To adjust the temperature in All Day mode, turn the dial to desired temperature then press > to confirm and automatically return to the homescreen.
Press < in the homescreen to exit All Day mode and return to Auto mode.
Heating under All Day mode will be on until 23:59 that day. At 23:59, the unit will exit All Day mode and return to Auto mode.
Set temperature range: 5oC – 35oC. Default: 21oC
Holiday Mode (HOLI)
To adjust the settings in Holiday mode, turn the dial to adjust holiday days, press > to confirm. Then turn the dial to adjust set temperature, press > to confirm and return to the homescreen. Press < in the homescreen to exit Holiday mode and return to Auto mode.
Holiday mode days setting range: 1 – 99 days. Default: 1 day
Set temperature range: 5oC – 35oC. Default: 7oC
N.B: The Days(Holiday) will numerically countdown. Once the countdown has finished normal operation will resume. It may be advisable to to set the Holiday mode 1 day less so the house is back up to temperature for your return.
Boost (bOSt)
To adjust the settings in Boost, turn the dial to enter the Boost setting and bOSt will display. Use the dial to adjust the number of hours for the boost to run, press > to confirm. Then turn the dial to adjust boost set temperature, press > to confirm and return to the homescreen. Press < in the homescreen to exit the Boost and return to Auto mode.
Boost hours setting range: 1 hour – 6 hours. Default: 2 hours
Set temperature range: 5oC – 35oC. Default: 21oC
N.B: The time remaining for the Boost will countdown. Once the countdown has finished normal operation will resume.
In the homescreen, press and hold > for 3 seconds then release to enter main menu. Use the dial to choose between tINE, ProG, CoPy, tEcH , CoUP and rESE. Press > to enter desired setting. Press < to return to Homescreen.
Copy Function (CoPy)
The unit is provided with a copy function which allows an adjusted programme to be copied to another day. N.B. This function only works in 7 Day setting.
To operate the copy function:-
Backlight On/Off (LIGH)
The backlight can be turned permanently on/off.
LIGH setting range: Off/On.
Default: Off
N.B. It is recommended to leave this setting in the default OFF mode as heat generated by the thermostat’s power supply and LED will affect temperature measurement. A deviation of up to 3.5°C may occur, which will be calibrated automatically by the unit within 30 minutes of first connecting the thermostat. It is recommended to leave the thermostat to climatise for 40 minutes before user opera-tion. If set permanently ON, the light will automatically switch to a lower light setting and be dimmer.
Resetting the Unit (rESE)
Resetting the unit will return the thermostat to default setting. The time, date and landlord service settings will all be maintained.
Factory Pre-Set Programme
This unit has been designed to be a simple-to-use thermostat, requiring minimal user intervention with a pre-programmed heating profile. The pre-set heating times and temperatures will suit most people (see table below).
Operation setting range: 5/2 day, 7 day, 24 Hour. Default: 5/2 Day
Events setting range: 6 events or 4 events. Default: 6 events
Pre-Set Temperatures: 5/2 Day
Mon-Fri pre-set time and temperature settings
Sat & Sun pre-set time and temperature settings
Setting the Operation Mode (5/2 day, 7 day, 24hr) (ProG)
Setting the Programme (ProG)
5/2 Day
7 Day
24 Hour
Setting Up the WiFi Connecttion
This WiFi thermostat works with the ESi Controls Centro APP which is available on iOS and Android.
Explanation of the WiFi Connecttion
Parameter Settings
All Day Mode | |
All day mode temperature | 5oC-35oC (Default: 21oC) |
Holiday Mode | |
Holiday mode temperature | 5oC-35oC (Default: 7oC) |
Holiday mode days | 1-99 days (Default: 1 day) |
Boost Function | |
Boost Temperature | 5oC-35oC (Default: 21oC) |
Boost Hours | 1-6 hours (Default: 2 hours) |
Default Mode | |
Temporary set temperature | 5oC-35oC (Default: 21oC) |
Program event start time | 00.00-24.00 (See 5.1 for details) |
Program event set temperature | 5oC-35oC (See 5.1 for details) |
Program operation mode | day) |
Number of programs | 4 or 6 (Default 6) |
Manual Mode | |
Manual mode temperature | 5oC-35oC (Default: 21oC) |
Delayed Start | |
DS | Off or On (Default Off) |
TPI | |
TPI | Off, 3 cycles or 6 cycles (Default Off) |
OFF Mode (Frost Protection) | |
Frost protection start temperature | 5oC |
temperature | 7oC |
Service | |
SERS | OFF or 1-4 (Default: Off) (See 9.1 for details) |
Service DATE | 28-366 days (Default 365 days) |
Other Functions | |
Operation MODE | Auto, Manual, Off (Default: Auto) |
Temperature calibration ADJ | 3.0oC-3.0oC (Default: 0oC) |
SWING | 0.5oC-2.0oC (Default: 1oC) |
Display backlight | Off/On (Default: Off) |
Thermostat Technical Settings
Power supply | 230VAC, 3(1)A SPDT |
Temperature Sensor Type | +/- 1oC at 20oC |
Total Switch Rating | 3(1)A 230 VAC |
Contact Type | SPDT (Volt Free changeover contacts) |
Plastic | Thermoplastic, flame retardant |
Protection Rating | IP30 |
Dimensions | 95mm (L) x 95mm (W) x 39mm (D) |
BST/GMT Time Change | Automatic |
Factory Pre-Set Programme | Yes, see 5.1 for details |
Complies with | EN 60730-1, EN 60730-2.7, EN 55014- 1:2006+A1:2009+A2:2011, EN 61000- 3-2:2014, EN 61000-3-3:2013, EN 55014-2: 2015, EN 60730-1:2011, EMC Directive 2014/30/EU, LVD Directive 2014/35/EU |
Installation Safety Instructions
The unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring Regulations. Isolate mains supply before commencing installation. Please read all instructions before proceeding.
Ensure that the fixed wiring connections to the mains supply is via a fuse rated at not more than 3 Amps and Class ‘A’ switch having a contact separation of a minimum of 3mm in all poles. The recommended cable sizes are 1.0mm sqr or 1.5mm sqr. No earth connection is required as the product is double insulated but ensure continuity of earth throughout the system.
General Safety Instructions
This product complies with the essential requirements of the following EC Directives:
Please leave the user instructions with the end user where they should be kept in a safe place for future reference.
Warning Notices
WARNING: ALWAYS ISOLATE THE AC MAINS SUPPLY BEFORE INSTALLING. THIS PRODUCT MUST BE FITTED BY A COMPETENT PERSON, AND INSTALLATION MUST COMPLY WITH THE GUIDANCE PROVIDED IN THE CURRENT EDITIONS OF BS767 (IEE WIRING REGULATIONS) AND PART “P” OF THE BUILDING REGULA-TIONS.
WARNING: DO NOT FIT THE RECEIVER TO A BACK PLATE THAT IS LIVE. SWITCH OFF MAINS BEFORE FITTING BACK PLATE AS LIVE AND NEUTRAL CONTACTS MAY TOUCH WHILE MOUNTING RECEIVER ON PLATE AND DAMAGE THE PRODUCT.
Maintenance
Always isolate the mains supply before commencing any work, servicing or maintenance on the system. And please read all instructions before proceeding. Arrange for an annual maintenance and inspection schedule to be carried out by a qualified person on every part of the heating and hot water system.
Fitting the Programmable Room Thermostat
The ideal position to locate the Programmable Room Thermostat is about 1.5m above floor level, in a location where the thermostat is accessible, reasonably lit and free from extremes of temperature and draughts. Do not position the thermostat near sources of heat, such as radiators, lights, TV, direct sunlight or on an outside wall.
Installing the Programmable Room Thermostat
Wiring Diagram
Quick Command Guide
Menu Technical Settings (tEcH)
Setting the Landlord Service (SErS)
Setting the Due Date (DAtE)
To set the due date, enter the landlord service settings (see section 9.1) and use the dial to select DAtE then press >. Use the dial to set the due date (between 28-366 days) then press > to confirm and return to landlord service settings.
Changing the Password (CODE)
To change the password, enter the landlord service settings (see section 9.1) and use the dial to select CODE then press >. Use the dial to set the first digit of the new password then press > to move to the next digit. Repeat this for all 4 digits. On the last digit, press > to confirm the new password. Then re-enter the chosen password using the dial and > button. On the last digit press > to confirm. If both inputted passwords match, the new password will be saved and the unit will return to the home screen. If the inputted passwords do not match, the unit will return to the landlord settings menu and this step (section 9.3) should be repeated.
WARNING: Interference with sealed parts renders the guarantee void. In the interests of continuous product improvement, we reserve the right to alter designs, specifications and materials without prior notice and cannot accept liability for errors.
ESi Controls Limited
sales@esicontrols.co.uk
www.esicontrols.co.uk
Download Manual:
ESI ESRTP5WiFi Programmable Room Thermostats User Instructions
ESI ESRTP5WiFi Programmable Room Thermostats User Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…