Wiring Diagram
Internal Wiring Diagram for CP4B
If the mains voltage output is required, 230V must be connected to terminal COM.
Important: Do not connect Mains Voltage to OpenTherm®terminals.
How your programmable thermostat works
When the thermostat is in AUTO mode, it will operate according to the times and temperatures that have been programmed. The user can select from 6 different programs per day, each with a time and a temperature. There is no of time, only a higher and a lower temperature setpoint. If the user does not want the thermostat to operate, set the temperature for this time to be low temperature. The thermostat will turn ON if the room temperature is lower than the setpoint for the current period.
Example: If P1 is set to be 21˚C at 6 am, and if P2 is set to be 10˚C at 8 am, the thermostat will look for the temperature to be 21˚C between 6 am and 8 am.
Mounting & Installation
Caution!
Mounting & Installation (Continued)
Resetting the thermostat Thermostat
Keypad lock and unlock
To lock the keypad, press and hold the +buttons – for 10 seconds. will appear on the screen. The keypad is now locked.
To unlock the keypad, press and hold+ the buttons – for 10 seconds. will disappear from the screen. The keypad is now unlocked.
Mon-Fri | 06:30 | 08:00 | 12:00 | 14:00 | 17:30 | 22:00 |
21˚C | 10˚C | 10˚C | 10˚C | 21˚C | 10˚C | |
Sat-Sun | 08:00 | 10:00 | 12:00 | 14:00 | 17:30 | 23:00 |
21˚C | 10˚C | 10˚C | 10˚C | 21˚C | 10˚C |
Mon-Fri | 06:30 | 08:00 | 12:00 | 14:00 | 17:30 | 22:00 |
21˚C | 10˚C | 10˚C | 10˚C | 21˚C | 10˚C | |
Sat-Sun | 08:00 | 10:00 | 12:00 | 14:00 | 17:30 | 23:00 |
21˚C | 10˚C | 10˚C | 10˚C | 21˚C | 10˚C |
Everyday | 06:30 | 08:00 | 12:00 | 14:00 | 17:30 | 22:00 |
21˚C | 10˚C | 10˚C | 10˚C | 21˚C | 10˚C |
Programming Modes
The CP4B Room Thermostat has the following programming modes available:
Adjust the program set in 5/2 Day mode
Copy function may only be used if the thermostat is in the 7d mode.
Set the times and temperatures for the day that you wish to copy from in the programming mode.
When still on the daily press the COPY button.
The day of the week that you have selected will be shown with ‘COPY’ below it.
The next day will begin to flash on the top of the screen.
Press the+ button to copy the times and temperatures to that day.
Press the -button to skip that day.
You can copy to multiple days using the +button.
Press the OK button when copying has been completed.
Temporary Override
When in AUTO mode, press the +or-buttons to adjust the temperature setpoint. ‘OvEr’ will appear on the screen.
Press OK or after 5 seconds the thermostat will operate to this temperature setpoint, until the next switching time.
To cancel a temporary override, press the OFF buttton and then press the
AUTO button to return to the automatic mode.
Permanent Override
Press the MAN button to enter the manual mode (Permanent Override),
‘MAN’ will appear on the screen.
Press+ the- buttons to adjust the temperature setpoint.
Press OK or after 5 seconds the thermostat will operate in this mode.
To cancel permanent override, press the OFF buttton to turn the
thermostat off or press the AUTO button to return to the automatic mode
Boost Function
Press the BOOST button, two or three times.
The time that the thermostat will boost will flash on the screen.
Press the OK button.
The temperature will now flash. Adjust the boost temperature setpoint by pressing the +or -buttons.
Press the OK button or wait for 5 seconds for the boost to activate.
‘BOOST TO’ will now be displayed on the screen with the time that the thermostat is activated to, displayed above the text.
Press the BOOST button again to deactivate the boost.
Boost Function
If you do not press any button after pressing the boost button, the boost will activate to a default boost setting of 21C
This will switch your heating system off between the start and end times you select.
Press the HOL button, and ‘HOLIDAY FROM’ will appear on the screen.
Press the +or- buttons to adjust the year. Press OK.
Press the +or -buttons to adjust the month. Press OK.
Press the +or-buttons to adjust the day. Press OK.
Press the +or- buttons to adjust the hour. Press OK.
‘HOLIDAY TO’ will appear on the screen.
Press the +or -buttons to adjust the year. Press OK.
Press the +or -buttons to adjust the month. Press OK.
Press the +or -buttons to adjust the day. Press OK.
Press the +or -buttons to adjust the hour. Press OK.
The thermostat will now return to the mode it was in before the Holiday settings were entered. To cancel Holiday mode, press the HOL button.
Backlight mode selection AUTO
There are two settings for selection. The factory default setting is AUTO.
OFF The backlight is permanently OFF.
AUTO On pressing any button the backlight stays on for 5 seconds.
To adjust the backlight setting, lower the cover on the front of the unit.
Press the OK button for 5 seconds.
Press either the +or- buttons to select the OFF or AUTO mode.
Press the OK button
Battery low warning
When the batteries are almost empty, the symbol
The batteries must now be replaced or the unit will shut down.
Replacing the batteries
Lower the flap on the front of the thermostat. There is a battery compartment located below the buttons. Apply downward pressure to remove the cover. Insert the 2 x AA batteries and the thermostat will turn on. Close the battery compartment.
Installer menu
To access the installer menu, you must hold Prog and OK for 5 seconds.
When in the installer menu, use the+,-, and OK to navigate and select.
Use AUTO, MAN, or OFF to go back a step.
Installer menu OpenTherm® Instructions
(Only for use with OT boilers)
Nor (Normal Mode)
When the thermostat is in Normal mode, the thermostat will try to reach the target temperature after the program changes. Example: Program 1 on the thermostat is 21°C for 06:30 am and the room temperature is 18°C. The thermostat will start heating at 06:30 am and the room temperature will start to increase then. PO 1 Operating Mode (Normal / Optimum Start / TPI)
OS (Optimum Start Mode) Boiler Plus
When the thermostat is in Optimum Start mode, the thermostat will try to reach the target temperature by the start time of the next switching time. This is done by setting the Ti (time interval) on the thermostat in this menu to 10, 15, 20, 25, or 30. This will allow the thermostats 10, 15, 20, 25, or 30 minutes to increase the room temperature by 1°C. Ti can be set when OS is selected in the installer menu. 20˚C
PO 1 Operating Mode (Normal / Optimum Start / TPI)
To achieve the target temperature when the program starts, the thermostat will read:
The time (in minutes) that it will take to overcome (TTD) is called Optimum Start Time (OST) and its maximum value is 3 hours = 180 mins. This is subtracted from the start time. As the temperature increases the thermostat will recalculate the OST if the temperature is increasing too quickly.
Example when Ti = 20
Program 1 on the thermostat is 21°C at 06:30 am and the room temperature is 18°C. The thermostat will start heating at 05:30 am to reach 21°C at 06:30 am @ Ti=20.
Example when Ti = 10
Program 1 on the thermostat is 21°C at 06:30 am and the room temperature is 18°C. The thermostat will start heating at 06:00 am to reach 21°C at 06:30 am @ Ti=10.
PO 1 Operating Mode (Normal / Optimum Start / TPI)
TPI (Time Proportional & Integral Mode)
When the thermostat is in TPI mode and the temperature is rising in the zone and falls into the Proportional Bandwidth section, TPI will start to affect the operation of the thermostat. The thermostat will turn on and off as it gains heat so that it doesn’t overshoot the setpoint by too much. It will also turn on if the temperature is falling so it doesn’t undershoot the setpoint which will leave the user with a more comfortable level of heat.
There are 2 settings that will affect the operation of the thermostat:
Example: Program 1 on the thermostat is 21°C for 06:30 am and the room temperature is 18°C. The thermostat will start heating at 06:30 am and the room temperature will start to increase then but will switch itself off before it reaches temperature and allow the room temperature to increase naturally – this cycle may begin again if the thermostat isn’t reaching temperature.
PO 2 Setting high & low limits High 35˚C and Low 5˚C
This menu allows the installer to change the minimum and maximum temperature range that the thermostat can be set at.
PO 3 Hysteresis HOn and Hoff
This menu allows the installer to change the switching differential of the thermostat when the temperature is rising and falling. HOn is the fall in temperature – Default – 0.4°C. This will allow a fall of 0.4°C from the setpoint before the thermostat turns on again. Hoff is the rise in temperature – Default – 0.0°C. This will allow the temperature to rise to 0°C above its setpoint.
PO 4 Calibrate the thermostat
This menu allows the installer to re-calibrate the thermostat. The current temperature will be displayed on the screen and can be adjusted by pressing the +buttons-.
PO 5 Frost Protection 5˚C
This menu allows the installer to activate or de-activate frost protection. When frost protection is activated the thermostat will switch on the boiler when the temperature drops below 5˚C.
PO 6 Exit
This menu allows the installer to return to the main interface. It is also possible to exit the installer menu by pressing AUTO, MAN, or OFF whilst in the installer menu.
PO 6 Setting DHW Temperature
This menu allows the installer to change the DHW temperature of the boiler. The temperature can be set in 0.5°C increments by pressing the+ or- buttons. Press the OK button to select the desired temperature. This menu is only available when the thermostat is connected to OpenTherm® and DHOP is ON (P08 OT installer menu).
This menu allows the installer to view information received from the OpenTherm® boiler. It may take a few seconds to load information relating to each parameter. The information that can be shown from the boiler is outlined in the table below.
Displayed on screen | Description | Remark |
tSEt | Target water temp | |
tFLO | Outlet water temp | |
trEt | Return water temp | |
tdH | DHW temperature | This is only visible if DHOP is On (P08 OT Installer menu) |
tFLU | Flue gas temperature | Dependent on boiler |
tESt | Outdoor temperature | Dependent on boiler |
nOdU | Modulation percentage | |
FLOr | Water flow | This is only visible if DHOP is On (P08 OT Installer menu) |
PrES | Water pressure | Dependent on boiler |
PO 8 DHOP
This menu allows the installer to activate or de-activate DHW target temperature control from the thermostat. This menu is only available when the thermostat is connected to OpenTherm®
PO 9 Set OpenTherm® Parameters
This menu allows the installer to configure the OpenTherm® parameters. To access the menu please enter the password “08” with the +or -buttons. Press OK to confirm. The parameters that can be set are outlined in the table below
Parameter | Description | Range | Default | |
HHCH | t-1 | Maximum set point heating | 45 – 85˚C | 85˚C |
LLCH | t-2 | Minimum set point heating | 10 – HHCH˚C | 45˚C |
CLI | t-3 | This allows users to select different climatic curves for weather compensation. This only applies to boilers with an outside sensor connected. | 0.2 – 3.0 | 1.2 |
InFL | t-4 | Influence of room sensor on modulation of the boiler. Recommended value is 10. | 0 – 20 | 10 |
HHbO | t-5 | Maximum allowable CH water setpoint. (˚C) | ID49 Max ≥ID57 ≥ID49 Min | 85˚C |
Exit | Press OK button to turn back to main interface. |
PO 9 Set OpenTherm® parameters
Climatic Curve
Exit
This menu allows the installer to return to the main interface. It is also possible to exit the installer menu by pressing AUTO, MAN or OFF whilst in the installer menu.
System architecture
Example A 1 no. The thermostat controlling OT Boiler
EPH Controls IE
sales@ephcontrols.com
www.ephcontrols.com
T +353 21 434 6238
F +353 21 454 5890
EPH Controls UK
© 2020 EPH Controls Ltd.
sales@ephcontrols.com
www.ephcontrols.com
T +44 1933 626 396
F +44 1933 626 218
DOWNLOAD MANUALS:
EPH CP4B Programmable Room Thermostat Installation Instructions
EPH CP4B Programmable Room Thermostat Installation Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…