Engocontrols

Engocontrols EONEBATW Programmable Room Thermostat QUICK GUIDE

Engocontrols EONEBATW Programmable Room Thermostat

Product Compliance
This product complies with the following EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/ EU, 2011/65/EU.

SAFETY INFORMATION
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Please read the entire manual, before installation or use.

WARNING: This product must be used with a ZigBee EGATEZB gateway (purchased separately). Thermostat programming is done by ENGO Smart app.

Product advantages

Built-in Li-Ion 3,7V Battery
Communication in the ZigBee 3.0 standard
A multitude of functions available from ENGO Smart / Tuya Smart application
S1-S2 Input for additional sensor
ENGO binding function (devices connection in Online and Offline mode)

INTRODUCTION

ONEBAT is a surface-mounted room thermostat which works over ZigBee technology. It has a built-in humidity sensor and a minimum/maximum setpoint temperature limiting function. The ONEBAT has the ability to work in heating or cooling modes. The unique feature of this thermostat is the possibility of wireless control over ENGO binding function. In order to have the ability to controll wirelessly, ONEBAT needs to be used with ENGO Smart / TUYA Smart mobile application and EGATEZB internet gateway (sold separately). „ENGO binding” function provides wireless and direct connection to the receivers (e.g. ECB62ZB control box, EMODZB module or EREL1ZB12A relay) over the EGATEZB gateway. After adding to the mobile app, thermostat offer more functions, e.g. push notifications or possibility of programming time schedules.

Technical Information

Power supply Built-in Li-Ion 3,7V Battery
Charging connector USB type C, 5V DC
Temperature range 5,0°C – 45,0°C
Display temperature accuracy 0,1°C
Control algorithm TPI or Histeresis (from ±0,1°C to ±2°C)
Communication ZigBee 3.0 2,4GHz
S1/S2 multifunctional input Floor temp sensor, external air sensor, occupancy sensor
IP protection class IP30
Dimension [mm] 90 x 90 x 14 mm

Wireless communication diagram

Connection description

Legend

Temperature sensor
Thermostat input for ext. temperature sensor
Connection with ZigBee 3.0 network
Connection with WiFi 2.4GHz network

LCD Icon Description + Button

  1. Current humidity reading
  2. Current Temperature / Setpoint Temperature
  3. Clock
  4. Temperature unit
  5. Heating indicator (icon is animating when there is heating demand)
  6. Cooling indicator (icon is animating when there is cooling demand)
  7. Schedule mode icon
  8. Temporary override mode
  9. External/Floor or Occupancy sensor
  10. Button lock
  11. Holiday mode
  12. Settings icon
  13. Battery indicator
  14. Receiver pairing indicator
  15. ZigBee network connection indicator
  16. Settings icon/temperature settings

Button description

Installation of thermostat in the app

Make sure your router is within range of your smartphone. Make sure you are connected to the Internet. This will reduce the pairing time of the device.

STEP 1: DOWNLOAD THE ENGO SMART APP

  • Download the ENGO Smart app from Google Play or Apple App Store and install it on your smartphone.

STEP 2: REGISTER THE NEW ACCOUNT

To register a new account, please follow the steps below:

  1. Click „Register” to create a new account.
  2. Enter the e-mail address to which the verification code will be sent.
  3. Enter the verification code received in the email. Remember that you only have 60 seconds to enter the code!!
  4. Then set the login password.

STEP 3: CONNECT THE THERMOSTAT TO ZigBee

  • Make sure ZigBee gateway has been added to the Engo Smart app.
  • Press and hold the and buttons on the thermostat for approx. 5 seconds until the display shows „PA”. Then release the keys. The pairing mode will be started up and counts the time back (180s).

  1. In the app, click on + upper right corner.
  2. Select: „Add Device”.
  3. When the ZigBee gateway finds the thermostat click the „Add” button.

Binding

Binding thermostat with the module/relay
Make sure that the module/relay and thermostat are in the same ZigBee network (they are added to the same gateway EGATEZB).

  • To properly link thermostat with the module/relay first click the button on the device 5 times. The LED diode will start flashing slowly on red, which means the device is in binding mode
  • On the EONE thermostat, hold and buttons until the “bind” message appears.
  • Release the keys, binding function process of linking thermostat with control box
  • The “binding” process takes up to 300 seconds.
  • After successfull binding operation „End” message will be displayed. LED on the module will stop flashing.
  • Both devices have been successfully linked. Thermostat displays the main screen, icon ” ” appeared on the screen indicating connection with the receiver (module/relay in this case).

ATTENTION: If the binding process fails, it must be repeated taking into account the distances between devices, obstacles and local radio signal interferences.

Remember: Radio range can be increased by Engo ZigBee repeaters.

Binding thermostat with the ECB62ZB wireless control box
Make sure that the ECB62ZB control box and thermostat are in the same ZigBee network (they are added to the same gateway EGATEZB) and the POWER LED lights up blue.

In order to correctly link the thermostat with the control box, first select the zone in the control box with the SELECT button (1) (zone which you want to link with the thermostat). The LED (2) will flash 3 times for the selected zone. Confirm your selection by clicking the PAIR button (2). The LED (2) will flash green with the previously selected zone – the binding process has started, it is active for 10 minutes and during this time you can link the thermostat with the selected zone.

  1. On the EONE thermostat, holdand buttons until the “bind” message appears.
  2. Release the keys, binding function process of linking thermostat with the control box is active.
  3. The “binding” process takes up to 300 seconds.

  1. After successfull binding operation „End” message will be displayed.
  2. Both devices have been successfully linked. Thermostat displays the main screen, icon “ ” appeared on the screen indicating connection with the receiver (ECB62ZB in this case).

ATTENTION: If the binding process fails, it must be repeated taking into account the distances between devices, obstacles and local radio signal interferences.

Remember

  • Radio range can be increased by Engo ZigBee repeaters.

Installer settings

To enter installer parameters press and hold button for 3 seconds.

Use or . button to move between parameters. Enter the parameter by . Edit the parameter using or . Confirm the new parameter value with the button.

Installer parameters

Pxx Function Value Desription Default value
P01 Clock format 12h 12 hour 24h
24h 24 hour

P02

Heating/Cooling Selection

Heating
Cooling
TPI UFH TPI for Underfloor Heating

 

 

 

TPI UFH

for heating HIS 1.0 for cooling

TPI RAD TPI for Radiators
TPI ELE TPI for Electrical Heating
HIS 0.2 SPAN +/-0,1°C
HIS 0.4 SPAN +/-0,2°C
P03 Control algorithm HIS 0.6 SPAN +/-0,3°C
HIS 0.8 SPAN +/-0,4°C
HIS 1.0 SPAN +/-0,5°C
HIS 2.0 SPAN +/-1,0°C
HIS 3.0 SPAN +/-1,5°C
HIS 4.0 SPAN +/-2,0°C
P04 Offset temperature -3.5°C do +3.5°C If the thermostat indicates wrong temperature, you can correct it by max ± 3.5°C” 0°C
P05 “Minimum setpoint” 5°C – 45°C Minimum heating / cooling temperature that can be set 5°C
P06 “Maximum setpoint” 5°C – 45°C Maximum heating / cooling temperature that can be set 35°C

P07

S1/S2 Input

1 Disable

1

2 External sensor as a floor sensor
3 External sensor as an air sensor
4 Occupnacy sensor (ON/OFF volt free input)
P08 Maximum floor temperature for heating (function active when P07=2) 5°C – 45°C In order to protect the floor, the heating will be turned off, when the temperature of the floor sensor rises above the maximum value. 35°C
P09 Minimum floor temperature for heating (function active when P07=2) 5°C – 45°C In order to protect the floor, the heating will be switched on, when the temperature of the floor sensor drops below the minimum value. 10°C
P10 Maximum floor temperature for cooling (function active when P07=2) 5°C – 45°C In order to protect the floor, cooling will be switched on, when the temperature of the floor sensor exceeds the maximum value. 15°C
P11 Minimum floor temperature for cooling (function active when P07=2) 5°C – 45°C In order to protect the floor, cooling will be turned off, when the temperature of the floor sensor drops below the minimum value 7°C

 

 

P12

 

 

Comfort warm floor

OFF

This function helps to keep the floor warm, even if there is no heating demand from the room thermostat.This feature is available only for Heating Mode. User can select 5 levels of warm floor feature. Note that comfort warm floor function will activate heating for specified amount of time (in relation to Level setting choosen by user). Heating will be activated only if in the past 1 hour heating was OFF.

 

 

OFF

Level 1 = 7min
Level 2 = 11min
Level 3 = 15min
Level 4 = 19min
Level 5 = 23min
P13 Valve protection ON Function disabled OFF
OFF Function enabled
P14 Backlight brightness 10% – 100% Adjustable in the range from 10 to 100% 50%
P15 PIN Code for settings access NO Function disabled NO
PIN Function enabled
P16 Require a PIN to unlock the keys every time (function active when P15=PIN) NO Function disabled NO
YES Function enabled
CLR Clear settings factory reset NO No action NO
YES Factory Reset

Factory reset

To RESET thermostat to factory settings, hold the and buttons for approx. 15 seconds. FA will be displayed. Then release the keys. Thermostat will restart, restore default (factory) settings and displays the home screen. The device will be removed from the ZigBee network you will need to add/pair it again.

Producer

  • Engo Controls S.C. 43-200 Pszczyna
  • 3E Górnośląska St. Poland

Distributor

  • QL CONTROLS Sp z o.o. Sp. k.
  • 43-262 Kobielice 4 Rolna St. Poland

REFERENCE:

DOWNLOAD MANUALS:

ENGO EONEBATW Internet Controlled Thermostat ZigBee User Guide

Engocontrols EONEBATW Programmable Room Thermostat QUICK GUIDE

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago