E901 & E901RF is a weekly, surface-mounted electronic room thermostat intended for home use. It has been designed for control of heating devices (e.g. gas, oil boilers, heat pumps) or cooling devices. It has the function of creating your own schedules. Thanks to the built-in algorithms, it offers much better temperature control accuracy than traditional mechanical thermostats. Please read these instructions carefully before using the device for the first time. The thermostat should use AA, 1.5V alkaline batteries. Put the batteries in the battery compartment located under the flap. Rechargeable batteries are not allowed.
This product complies with the following EU Directives:
E901: 2014/30/EU, 2014/35/EU, 2011/65/EU
E901RF: 2014/53/EU, 2011/65/EU 868.0 MHz – 868.6 MHz; <13dBm
Please note!
This document is a quick guide for installing and operating the product and indicates its most important features and functions
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations
Installation must be performed by a qualified person with appropriate electrical qualifications, in accordance with the standards and regulations in force in a given country and in the EU. The manufacturer is not responsible for non-compliance with the instructions.
WARNING:
For the entire installation, there may be additional protection requirements, which the installer is responsible for.
On sale, exchange or disposal of a device we recommend you reset or delete any device settings. Internet connected devices should be removed from any registered online accounts, Mobile or Web Apps, or the online account should be closed to ensure device data is no longer linked or associated with your personal details. It is the consumer’s responsibility to remove a device, close an account, or notify us of any change in ownership to ensure any association or linkage to personal accounts is removed or updated.
Remove the thermostat cover as shown in the picture.
If there are batteries inside, remove them.
Use a screwdriver to push the plastic tabs in as shown in the figure until you feel resistance, and tilt the front part of the housing.
Separate the front part from the back part in the direction shown above.
Then fix the back cover to the wall using the supplied mounting screws and the holes provided (see bigger arrows). Connect the wires to the COM / NO connector (see smaller arrows).
Using the hinges from left, fold the back and front covers by moving as shown in the picture above until they click into place.
Receiver’s switches description:
LEFT SWITCH | |
1. | ON – Manual mode – receiver ON |
2. | OFF – Manual mode – receiver OFF |
RIGHT SWITCH | |
3. | MANUAL – Receiver works in manual mode (according to the left switch) |
4. | AUTO – Receiver works in AUTO mode (according to the thermostat’s command) |
The status of the receiver is indicated by two LEDs. These are LEDs with the following colors:
A detailed explanation of the meaning of the LEDs can be found in the table below:
DESCRIPTION | |
The green LED lights up | The receiver is connected to the 230V power supply. The receiver can be controlled by thermostat if it is in automatic mode when the right switch is in the AUTO position. The receiver can be started manually when the right switch is in the MANUAL position. |
The green LED flashes | The receiver is in the pairing mode and is looking for a signal from the thermostat (then you must activate the“SYNC” parameter in the thermostat). |
The green LED is off | The receiver is disconnected from the 230V power supply or the left switch is in the OFF position. |
The orange LED lights up | In automatic mode, the receiver received a heating / cooling signal from the thermostat. }The receiver was started in manual mode (left ON switch, right MANUAL switch) |
The orange LED flashes | The receiver was paired but lost communication with the thermostat due to out of range or low battery in the thermostat. The receiver starts flashing after 40 minutes of time when it does not receive a signal from the thermostat. |
The orange LED is off | The receiver does not send a heating / cooling signal. |
Connection description for wireless thermostat E901RF
Button | Function |
Change the parameter value down | |
Change the parameter value up | |
D | Set the day of the week |
H | Set the hour |
M | Set the minutes |
Comfort temperature | |
Economic temperature / Holiday mode | |
AUTO mode / Back button | |
Programming / Program selection | |
Confirm function | |
Factory Reset |
Setting Time / Setting Date
D
– Press D button to set the day.
H
– Press H button to set the hour.
M
– Press M button to set the minutes.
There are several temperature levels at our disposal. Only one temperature level is realized 24 hours a day in manual mode. You can set a different temperature for each level.
The values of these temperatures are taken into account in the automatic mode (for the first type of schedule -> see next page).
Press
Using
Confirm by
Setting the economic temperature
Press
Using
Confirm by
The first type of schedule (factory set with a time line) and its programming is described below:
There are 9 programs available. Programs 0-3 are factory programs. Programs 4-9 can be defined by user.
Press
Select the week period using
Confirm by
Using
Press
Select the week period using
Using
Then – each time you press the sun –
PLEASE NOTE! Programs should be set for each week days.
The second type of schedule and the programming method is described below
Press
Using
Confirm by
Press
Select the week period using
Using
Use
The thermostat will proceed to set the next program (a maximum of 6 programs can be set).
Programs should be set for each week days.
If you want to re-pair the devices with each other, make sure that the receiver is disconnected from the power supply, and the switches on it are in the ON and AUTO positions. Then connect the receiver to the power supply and wait for the green diode to glow continuously. Next, move the left switch to the OFF position and back to the ON position with a quick motion. After all, the green diode will start blinking, which will confirm that the receiver has entered the pairing mode.
Press
Use
Confirm b
Using
The thermostat started to send a signal to find the receiver (the symbol of the blinking antenna) and started the countdown with the number 10 (min). The pairing process may take up to 10 minutes
When the green diode on the receiver lights up continuously, the devices have been paired on a new frequency
The thermostat will display the message „good”, which means that the devices are successfully paired with each other.
The thermostat will return to the main screen.
To enter installer parameters press and hold
You are in the installer mode. Use
Pxx | Function | Value | Description | Default value |
P01 | Heating/Cooling Selection | Cooling | ||
Heating | ||||
P02 | Control method temperature | 1 | SPAN ±0,25°C | 1 |
2 | SPAN ±0,5°C | |||
3 | TPI for Underfloor Heating | |||
4 | TPI for Radiators | |||
5 | TPI for Electrical Heating | |||
P03 | Display temperature resolution | 0,5°C | This parameter specifies the accuracy of the displayed (measured) temperature. | 0,5°C |
0,1°C | ||||
P04 | Offset temperature | -3.5°C to + 3.5°C | If the thermostat indicates wrong temperature, you can correct it by ± 3.5°C | 0°C |
P05 | Relay type | NO | Normally Open type of relay | NO |
NC | Normally Closed type of relay | |||
P06 | Clock format | 24h | 24 hour | 24h |
12h | 12 hour | |||
P07 | Temperature Scale | °C | Celsius | °C |
°F | Fahrenheit | |||
P08 | Minimum setpoint | 5°C – 34,5°C | Minimum heating / cooling temperature that can be set | 5°C |
P09 | Maximum setpoint | 5,5°C – 35°C | Maximum heating / cooling temperature that can be set | 35°C |
P10 | Key sound | NO | Off | YES |
YES | On | |||
P11 | PIN Code | NO | Disabled | NO |
PIN | Enabled | |||
P12 | Require a PIN to unlock the keys every time | NO | Function disabled | YES |
YES | Function enabled | |||
CLR | Clear settings factory reset | NO | No action | NO |
YES | Factory Reset | |||
*Only for E901RF thermostat | ||||
SYNC | Pairing function with receiver (SYNC) | NO | Function disabled | NO |
Wired thermostat E901
Thermostat supply | 2 x AA batteries |
Rating max | 5 (3) A |
Outputs | Voltage-free NO/COM relay |
Temperature range |
Wireless thermostat E901RF (868 MHz)
Thermostat supply | 2 x AA batteries |
Receiver supply | 230 V AC 50 Hz |
Receiver rating max | 16 (5) A |
Receiver outputs | x 16 (5) A Receiver outputs Voltage-free NO/COM relay |
Temperature range | 5 – 35°C |
DOWNLOAD MANUALS:
ENGO CONTROLS E901RF Series Programmable Thermostat User Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…