This digital socket combines a switch socket for timed activation/deactivation of home appliances with a thermostatic socket for automatic regulation of electrical heating and cooling systems (convector heaters, ladder radiators, infrared heating panels, air-conditioning).
Power supply: 230 V~, 50 Hz, 16 A max.
IP rating: IP30
Operating temperature: 0 °C to 55 °C
increment for setting time: 1 minute
Switched load: max. 230 V AC, 3,680 W; 16 A for resistive load; 4 A for inductive load
Temperature measurement: 0 °C to 45 °C with 0.1 °C resolution; accuracy ±1 °C at 20 °C
Temperature setting: 5 °C to 40 °C in 0.5 °C increments
Temperature differential setting: 0.2 °C to 2 °C, in 0.1 °C increments
Back-up power supply: 1× 3 V CR2032 battery (included)
Dimensions: 82 × 62 × 146 mm
Back-Up Battery Replacement
The back-up battery is used to power the socket‘s memory. The expected battery life is 2 years. When
Socket Placement
Choose a spot preferably on an inside wall where air circulates freely and there is no direct sunlight. The connected heating appliance should be at a sufficient distance from the socket to prevent the devices from influencing each other. Otherwise, the socket may activate the appliance when not needed.
Putting the Device into Operation
Plug the socket into a 230 V/50 Hz socket; the screen will activate. Plug the appliance into the thermostatic socket.
Activating Thermo-Switch Socket (Thermostat) Mode
Long-press the TIME and MODE buttons at the same time to access settings. Repeatedly press the + and – buttons to select the mode marked as „
The settings below are only available when in thermostat mode!
Heating or Cooling Mode
Long-press the TIME and MODE buttons at the same time and then press the TIME button 1×. Use the + and – buttons to choose between heating
Temperature Differential Setting
Use the + and – buttons to set a value of 0.2 °C to 2 °C, with 0.1 °C resolution. Confirm by pressing TIME; this will open:
Room Temperature Calibration
Use the + and – buttons to set a value of -3 °C to +3 °C, with 0.5 °C resolution. Wait 30 seconds or press MODE to save the setting and return to the main screen. Explanation of functions:
Temperature Differential Setting
The temperature differential (hysteresis) is the difference in temperature required for switching the system on and off. If, for example, you set the temperature in heating mode to 20 °C and differential to 0.2 °C, the thermostat activates heating as soon as room temperature drops to 19.8 °C and switches heating off when temperature reaches 20.2 °C.
Room Temperature Calibration
The temperature sensor in the thermostat is calibrated from production, but additional calibration can be done to optimise the thermostat further, for instance by comparing the measured room temperature with a reference thermometer.
Setting Day and Time
Press the TIME button; the day number will begin flashing. Use the + and – buttons to set the current day and press TIME to confirm. The month number will start flashing. Use the + and – buttons to set the current month and press TIME to confirm. The year will start flashing. Use the + and – buttons to set the current year and press TIME to confirm. The hour will start flashing. Use the + and – buttons to set the current hour and press TIME to confirm. The minute will start flashing. Use the + and – buttons to set the current minute and press TIME to confirm. Wait 30 seconds or press MODE to save the setting and return to the main screen.
Table of Factory Preset Programmes (Max. 6 Temperature Changes a Day)
Setting Programmes – Automatic Mode
If the factory preset programmes do not suit your needs, you can adjust their timing and temperatures. The day can be divided into a maximum of 6 time periods = 6 temperature changes.
Note: If you wish to delete a set programme, long-press the TIME button when the time is flashing. Move forward in settings by pressing the TIME button; pressing the PROG navigates one step back in settings.
Manual Temperature Mode
Press the MODE button until SET and a temperature value appear on the right of the screen. Use the + and – buttons to set the temperature and wait 5 seconds for the setting to automatically save. The set temperature will be maintained until you cancel manual mode.
Short-Term Manual Temperature Change
When in automatic mode, where temperature is controlled by the selected programme, it is possible to make a short-term change to the current temperature setting. While in automatic temperature control mode (AUTO and P – programme number displayed on the left side of the screen) use the + and – buttons to set the new temperature and wait 5 seconds for the setting to automatically save. P – programme number will disappear from the screen; AUTO will remain. The manually set temperature will be maintained until the programmed temperature change.
OFF Mode
Press the MODE button until OFF appears on the screen. The room temperature and clock will be displayed, but current output from the socket will be turned off. To reactivate the socket, press MODE repeatedly to set the socket to either the automatic or manual temperature control mode.
BOOST Mode
The BOOST feature can be used to heat up a room in a short time. Press the BOOST button repeatedly to choose the time frame (30 min to 9 hours, 30 min resolution). Then, use the + and – buttons to choose temperature; the setting will be saved automatically. The chosen temperature will be valid for the entire set period. The time and temperature remaining will flash on the screen along with the room temperature and the clock. Once the time elapses, the system will automatically switch back to the previous temperature mode and the previously set temperature. To end the BOOST function prematurely, use the MODE button to select a different temperature mode or press the BOOST button repeatedly until the time setting reaches 9 hours; the next press will deactivate the BOOST function.
Activating Timer Switch Socket Mode
Long-press the TIME and MODE buttons at the same time to access settings. Repeatedly press the + and – buttons to select the mode marked as „
Setting Day and Time
Press the TIME button; the day number will begin flashing. Use the + and – buttons to set the current day and press TIME to confirm. The month number will start flashing. Use the + and – buttons to set the current month and press TIME to confirm. The year will start flashing. Use the + and – buttons to set the current year and press TIME to confirm. The hour will start flashing. Use the + and – buttons to set the current hour and press TIME to confirm. The minute will start flashing. Use the + and – buttons to set the current minute and press TIME to confirm. Wait 30 seconds or press MODE to automatically save the setting and return to the main screen.
Table of Factory Preset Times
Setting Programmes – Automatic Mode
If the factory settings do not suit your needs, you can adjust the timing of the programmes.
You can set a maximum of 24 time programmes.
Note: If you wish to delete a set programme, long-press the TIME button when the time is flashing. Move forward in settings by pressing the TIME button; pressing the PROG navigates one step back in settings.
BOOST Mode (Countdown)
The countdown function enables turning off an appliance after a preset time. Press the BOOST button repeatedly to choose the time frame (30 min to 9 hours, 30 min resolution). The countdown from the set time will start automatically.The time remaining will be flashing on the screen alongside the mode icon (
Note: The BOOST function cannot be used in manual mode (ON).
Manual Mode (ON)
Press the MODE button repeatedly until ON and the mode icon (
OFF Mode
Press the MODE button until OFF appears on the screen. The clock will remain on the screen but the current output from the socket will be turned off. To reactivate the socket, press MODE repeatedly to set the socket to either the automatic (AUTO) or manual (ON) temperature control mode.
Screen Illumination
Pressing any button activates screen illumination for 15 seconds.
Factory Reset
If the socket is not working properly, you can reset it to factory settings. Long-press the PROG button and insert e.g. a straightened paper clip into the RESET hole; you will hear a click. The screen will display all segments/icons; release the PROG button.
Safety Warnings
Do not dispose with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If the electronic devices would be disposed on landfill, dangerous substances may reach groundwater and subsequently food chain, where it could affect human health.
Servis: EMOS SI, d.o.o.,
Rimska cesta 92,
3311 Šempeter v Savinjski dolini,
Slovenija
tel: +386 8 205 17 21
e-mail: reklamacije@emos-si.si
Download Manual:
EMOS P5660SH socket Thermostat Installational Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…