The P5603R thermostat is designed for controlling heating and air-conditioning systems.
Switched load: max. 230 V AC; 6 A for resistive load; 2 A for inductive load
Temperature measurement: 0 °C to 40 °C with 1 °C resolution; accuracy ±0.5 °C
Temperature setting: 5 °C to 30 °C in 1 °C increments
Temperature differential setting: 0.4 °C
Power supply: 2× 1.5 V type AA (LR6) batteries
Accessories: 2 screws, 2 wall plugs
Dimensions and weight: 40 × 93 × 86 mm; 135 g
Description of the Thermostat (See Fig. 1)
Screen Description (See Fig. 2)
Procedure for Removing the Front of the Thermostat (See Fig. 1)
Attention:
Before changing the thermostat, disconnect the heating/air-conditioning system from the mains power in your flat. This will prevent potential injury by electric current. Read the thermostat manual carefully before using the device for the first time. Turn off power supply before installing the thermostat! Follow applicable standards during installation.
Placement of the Thermostat
The placement of the thermostat significantly affects its functioning. Choose a location where family members spend most of their time, preferably on the inside wall where air circulates freely, with no direct sunlight. Do not place the thermostat in the vicinity of heat sources (such as TV sets, radiators, fridges), or close to a door (due to frequent shocks or vibrations). If you do not follow these recommendations, the thermostat will not maintain room temperature correctly.
The rear cover of the thermostat has 6 pre-made openings for mounting onto a wall. Remove the rear cover and use the enclosed screws and wall plugs to mount the thermostat to a wall. The connection terminals are protected by a plastic cover, see Fig. 3. Connect the wires leading out of the junction box to the marked terminals on the thermostat in accordance with the wiring diagram.
Voltage connection diagram for connecting thermostat P5603R to a boiler with an „NO“ contact:
When connecting a cooling device to the thermostat, connect the „L“ phase conductor to the „NC“ terminal.
Zero-voltage connection diagram for connecting thermostat P5603R to a boiler with an „NO“ contact:
Putting the Device into Operation
Setting Temperature
To increase temperature, turn the wheel right. To reduce temperature, turn the wheel left. The set temperature will be shown on the screen for 5 seconds, then the room temperature will be shown instead.
Choosing Operating Mode
Unscrew the rear cover of the thermostat. There is a DIP switch on the back of the thermostat which is used to set the following functions.
Available Functions in HEATING Mode
CHRONO (TPI) Mode
CHRONO mode, also known as TPI (Time Proportional and Integral) is an algorithm that has a simple memory capable of „learning“ how to reach and maintain room temperature.
It has a basic calculating capability: It uses collected data and current temperatures and predicts how long heat needs to be generated (the boiler must remain on). It is a type of intelligent control, since heat delivery lasts until the desired value is reached, then the boiler is turned off to improve energy efficiency. The mode runs in cycles, with their length measured as number of cycles per hour. During normal use, it is difficult to notice the difference in the way the heating system runs. However, it is noticeable that the thermostat runs for a shorter period of time when room temperature starts approaching the set temperature. Once the set temperature is reached, the operating cycles become shorter to maintain the temperature. TPI calculates the speed at which the room loses heat and prevents the room from getting colder by activating heating as needed.
Setting CHRONO (TPI) Cycles
In heating mode, the CHRONO function can be set to 3 or 6 cycles per hour. 3 cycles are recommended for controlling underfloor heating or controlling a heat pump. 6 cycles are recommended for controlling a gas boiler or a zone valve.
Temperature Differential Setting
If you turn off the CHRONO function, the thermostat will activate/deactivate based on the temperature differential. The temperature differential (hysteresis) is the difference in temperature required for switching the system on and off. The differential value is 0.4 °C. If, for example, you set the temperature in heating mode to 20 °C, the thermostat activates heating as soon as room temperature drops to 19.6 °C and switches heating off when temperature reaches 20.4 °C.
Available Functions in COOLING Mode
Delay prevents the thermostat from switching because of short-term temperature changes – protects the boiler from frequently activating and deactivating.
The product is designed to serve reliably for many years if used properly.
Here are some tips for proper operation:
Do not dispose with domestic waste. Use special collection points for sorted waste. Contact local authorities for information about collection points. If the electronic devices would be disposed on landfill, dangerous substances may reach groundwater and subsequently food chain, where it could affect human health.
Servis: EMOS SI, d.o.o.,
Rimska cesta 92,
3311 Šempeter v Savinjski dolini,
Slovenija
tel: +386 8 205 17 21
e-mail: reklamacije@emos-si.si
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…